In vitro analysis of antiseptic solution effects on <i>Staphylococcus aureus</i> biofilms on orthopedic implant materials

Abstract. Implant-related biofilm infections remain a major challenge in orthopedic surgery. Prior in vitro comparisons have focused on arthroplasty surfaces using static models; fracture fixation implants remain unstudied. We compared six antiseptic solutions against mature S. aureus biofilms on stainless steel, the most common fracture fixation metal, using a continuous-flow CDC biofilm reactor, more closely approximating hydrodynamic surgical conditions than static systems. Mature biofilms were created on stainless steel coupons using a continuous-flow reactor for 72 h, then washed for 3 min with one of six irrigation solutions: normal saline, 10 % PI (povidone-iodine), 0.35 % PI, a 10 % PI + 3 % hydrogen peroxide mixture, hypochlorous acid, or 0.05 % chlorhexidine gluconate. Colony-forming units (CFUs) were quantified following standardized sonication and plating, and mixed-effects negative binomial regression was used to estimate treatment effects. All antiseptic solutions produced statistically significant reductions in biofilm-associated CFUs relative to untreated controls. Ten percent PI demonstrated the greatest reduction (3.46-log 10), with 0.35 % PI producing a similar 3.42-log 10 reduction. The PI–hydrogen peroxide mixture achieved a 3.24-log 10 reduction without evidence of synergistic activity. Hypochlorous acid and chlorhexidine produced 2.95-log 10 and 2.46-log 10 reductions, respectively, while saline demonstrated minimal effect. These findings indicate that PI solutions, even at dilute concentrations, are highly effective at disrupting established biofilms on stainless steel. As an in vitro single-organism model, these findings establish a comparative efficacy baseline on a fracture-fixation-relevant surface but require validation in multispecies, multi-material, and mechanically realistic irrigation systems before clinical translation.

Authors

Institutions

Publication Details

Journal
Journal of Bone and Joint Infection
Published
2026-08-13
DOI
https://doi.org/10.5194/jbji-11-493-2026
Primary Topic
Orthopedic Infections and Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In vitro analysis of antiseptic solution effects on Staphylococcus aureus biofilms on orthopedic implant materials

Kenneth Chrulski, Ashley E. Levack, Marina Feffer, Madison Balagtas et al.
Journal of Bone and Joint Infection
Orthopedic Infections and Treatments
article

In vitro analysis of antiseptic solution effects on Staphylococcus aureus biofilms on orthopedic implant materials

Kenneth Chrulski, Ashley E. Levack, Marina Feffer, Madison Balagtas, Matthew Baldridge
article en

Abstract

Abstract. Implant-related biofilm infections remain a major challenge in orthopedic surgery. Prior in vitro comparisons have focused on arthroplasty surfaces using static models; fracture fixation implants remain unstudied. We compared six antiseptic solutions against mature S. aureus biofilms on stainless steel, the most common fracture fixation metal, using a continuous-flow CDC biofilm reactor, more closely approximating hydrodynamic surgical conditions than static systems. Mature biofilms were created on stainless steel coupons using a continuous-flow reactor for 72 h, then washed for 3 min with one of six irrigation solutions: normal saline, 10 % PI (povidone-iodine), 0.35 % PI, a 10 % PI + 3 % hydrogen peroxide mixture, hypochlorous acid, or 0.05 % chlorhexidine gluconate. Colony-forming units (CFUs) were quantified following standardized sonication and plating, and mixed-effects negative binomial regression was used to estimate treatment effects. All antiseptic solutions produced statistically significant reductions in biofilm-associated CFUs relative to untreated controls. Ten percent PI demonstrated the greatest reduction (3.46-log 10), with 0.35 % PI producing a similar 3.42-log 10 reduction. The PI–hydrogen peroxide mixture achieved a 3.24-log 10 reduction without evidence of synergistic activity. Hypochlorous acid and chlorhexidine produced 2.95-log 10 and 2.46-log 10 reductions, respectively, while saline demonstrated minimal effect. These findings indicate that PI solutions, even at dilute concentrations, are highly effective at disrupting established biofilms on stainless steel. As an in vitro single-organism model, these findings establish a comparative efficacy baseline on a fracture-fixation-relevant surface but require validation in multispecies, multi-material, and mechanically realistic irrigation systems before clinical translation.

Journal of Bone and Joint InfectionVol. 11(4)
Loyola University Medical Center (US), Loyola University Chicago (US)
Division of Microbiology and Infectious Diseases, National Institute of Allergy and Infectious Diseases
Openalex Percentile: Top 7%
Orthopedic Infections and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.