The Prospective SPOTLESS Trial: Setup Accuracy of Tattoo-Less Surface-Guided Breast Radiotherapy Including Regional Nodal Irradiation

Background/Objectives: The implementation of tattoo-free radiotherapy (RT) for breast cancer reflects an effort to mitigate the psychological distress of permanent marks through surface-guided techniques, while simultaneously evaluating its utility in meeting setup precision requirements. Methods: In this prospective trial, patients were positioned for breast cancer RT including regional nodal irradiation exclusively using surface-guided RT (SGRT). Cone-beam computed tomography (CBCT) was acquired at each fraction as the ground truth to analyze translational setup deviations. Results: A total of 457 paired SGRT–CBCT data points in 30 patients were acquired. A residual translational setup deviation of ≤6 mm was achieved in 97.6% of all fractions with a median deviation of 2 mm (range: 0–12). Neither age, comorbidities, body mass index, extent of target volumes, choice of breathing technique, nor patient-reported symptoms (pain, dermatitis, anxiety) correlated significantly with setup deviations. The median in-room positioning time was 92 s (range: 20 s–6 min and 37 s) and significantly prolonged in patients with an elevated BMI and higher grades of pain and skin dermatitis, and for chest wall irradiation. Manual assessment of the accuracy of regional nodal CTVs in each CBCT relative to the planning CT showed good-to-minor deviations in 99.7% (Level 1/2), 95.0% (Supra-/infraclavicular), and 90.8% (Internal mammary), respectively, with major deviations in only 0.3% (Level 1/2), 5.0% (Supra-/infraclavicular) and 9.2% (Internal mammary). A forward dose calculation on CBCT geometries (n = 86) revealed high median CTV dose coverage of 100.0% (range: 57.1–107.7%) of the original target dose for all lymph node levels combined. Conclusions: The tattoo-free positioning setup for regional nodal irradiation in breast cancer patients exhibited pronounced robustness, maintaining its accuracy and reliability irrespective of patient-, tumor-, or treatment-specific variables with high clinical efficiency. However, larger cohorts are required to confirm whether these parameters genuinely operate independently of setup accuracy.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-08-13
DOI
https://doi.org/10.3390/jcm15166253
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Prospective SPOTLESS Trial: Setup Accuracy of Tattoo-Less Surface-Guided Breast Radiotherapy Including Regional Nodal Irradiation

Semi Harrabi, Jakob Liermann, Eva Meixner, Line Hoeltgen et al.
Journal of Clinical Medicine
Advanced Radiotherapy Techniques
article

The Prospective SPOTLESS Trial: Setup Accuracy of Tattoo-Less Surface-Guided Breast Radiotherapy Including Regional Nodal Irradiation

Semi Harrabi, Jakob Liermann, Eva Meixner, Line Hoeltgen, Sebastian Klüter, Nathalie Arians, Klaus K Herfarth, Jürgen Debus, Vania Batista, Hanna Waldsperger, Adriana Ayestarán-Aldaz, Fabian Weykamp, Stephan Mende, David Neugebauer, Sophia Albert, Bahar Cepni, Lars Wessel, Julian Thater, Hin Hoi Lau
article en

Abstract

Background/Objectives: The implementation of tattoo-free radiotherapy (RT) for breast cancer reflects an effort to mitigate the psychological distress of permanent marks through surface-guided techniques, while simultaneously evaluating its utility in meeting setup precision requirements. Methods: In this prospective trial, patients were positioned for breast cancer RT including regional nodal irradiation exclusively using surface-guided RT (SGRT). Cone-beam computed tomography (CBCT) was acquired at each fraction as the ground truth to analyze translational setup deviations. Results: A total of 457 paired SGRT–CBCT data points in 30 patients were acquired. A residual translational setup deviation of ≤6 mm was achieved in 97.6% of all fractions with a median deviation of 2 mm (range: 0–12). Neither age, comorbidities, body mass index, extent of target volumes, choice of breathing technique, nor patient-reported symptoms (pain, dermatitis, anxiety) correlated significantly with setup deviations. The median in-room positioning time was 92 s (range: 20 s–6 min and 37 s) and significantly prolonged in patients with an elevated BMI and higher grades of pain and skin dermatitis, and for chest wall irradiation. Manual assessment of the accuracy of regional nodal CTVs in each CBCT relative to the planning CT showed good-to-minor deviations in 99.7% (Level 1/2), 95.0% (Supra-/infraclavicular), and 90.8% (Internal mammary), respectively, with major deviations in only 0.3% (Level 1/2), 5.0% (Supra-/infraclavicular) and 9.2% (Internal mammary). A forward dose calculation on CBCT geometries (n = 86) revealed high median CTV dose coverage of 100.0% (range: 57.1–107.7%) of the original target dose for all lymph node levels combined. Conclusions: The tattoo-free positioning setup for regional nodal irradiation in breast cancer patients exhibited pronounced robustness, maintaining its accuracy and reliability irrespective of patient-, tumor-, or treatment-specific variables with high clinical efficiency. However, larger cohorts are required to confirm whether these parameters genuinely operate independently of setup accuracy.

Journal of Clinical MedicineVol. 15(16)
German Cancer Research Center (DE), Heidelberg University (DE), University Hospital Heidelberg (DE), Heidelberger Institut für Radioonkologie (DE), National Center for Tumor Diseases (DE)
Good health and well-being
Openalex Percentile: Top 10%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.