Quantifying the effects of eccentrically drilled distal interlock screws in cadaveric tibias

OBJECTIVES: Intramedullary nailing (IMN) is the standard treatment for tibial shaft fractures; however, postoperative malalignment remains a relevant complication. Deviations in distal nail position can influence tibial alignment, and eccentric drilling during distal interlocking screw placement may alter fracture reduction and length. The purpose of this study was to quantify the effect of intentionally eccentric distal interlocking screw placement on tibial alignment in a controlled cadaveric model. METHODS: Ten paired, formalin-fixed, human-cadaveric tibias underwent standardized IMN via suprapatellar approach following reaming of 1.5mm over nail diameter. A simulated comminuted distal tibia-fibula fracture was created using a 2-cm defect 4-cm proximal to the plafond. A 10mm IMN was then seated and secured with a 60mm interlocking screw, placed in the medial-to-lateral proximal oblique hole. Crossing K-wires were placed in the coronal and sagittal planes to serve as markers for angular and axial displacement. Using fluoroscopic "perfect-circles" technique, three surgeons performed standardized, intentional, eccentric-drilling with proximal-to-distal trajectory. Distal screw placement was performed in the medial-lateral plane, then removed and repeated in the anterior-posterior plane. Coronal and sagittal angulation and axial length were measured by digital goniometer and calipers following screw insertion, respectively. RESULTS: For medial-lateral screws, proximal-to-distal eccentric drilling yielded a mean coronal angulation of 6.0° induced valgus (SD= 3.8°, R:1.5°min-12.2°max). While for anterior-posterior screw placement, proximal-to-distal eccentric drilling yielded a mean of 5.8° procurvatum (SD = 2.0°, R: 2.8°min-8.5°max). Translational distraction in the coronal plane was 3.0mm (SD = 2.2mm, R: 0.05mmmin-7.8mmmax), and distraction in the sagittal plane was 3.9mm (SD = 3.0mm, R: 1.1mmmin,-9.8mmmax). CONCLUSION: Eccentric distal interlocking screw placement produced radiographically appreciable angular and axial changes in distal tibial IMN constructs. Deviations during the "perfect-circles" technique can generate malalignment, or alternatively, be used to fine tune reduction in theory. Precise distal screw trajectory and strategies to minimize drilling eccentricity may reduce postoperative malalignment, particularly in distal tibial fractures. LEVEL OF EVIDENCE: Level V.

Authors

Publication Details

Journal
Journal of Orthopaedic Trauma
Published
2026-08-13
DOI
https://doi.org/10.1097/bot.0000000000003256
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantifying the effects of eccentrically drilled distal interlock screws in cadaveric tibias

Raja Ullah, Thomas L. Hand, Casey McDonald, Katerina Papanikolaou et al.
Journal of Orthopaedic Trauma
Bone fractures and treatments
article

Quantifying the effects of eccentrically drilled distal interlock screws in cadaveric tibias

Raja Ullah, Thomas L. Hand, Casey McDonald, Katerina Papanikolaou, Andrew Ni, Cameron Atkinson
article en

Abstract

OBJECTIVES: Intramedullary nailing (IMN) is the standard treatment for tibial shaft fractures; however, postoperative malalignment remains a relevant complication. Deviations in distal nail position can influence tibial alignment, and eccentric drilling during distal interlocking screw placement may alter fracture reduction and length. The purpose of this study was to quantify the effect of intentionally eccentric distal interlocking screw placement on tibial alignment in a controlled cadaveric model. METHODS: Ten paired, formalin-fixed, human-cadaveric tibias underwent standardized IMN via suprapatellar approach following reaming of 1.5mm over nail diameter. A simulated comminuted distal tibia-fibula fracture was created using a 2-cm defect 4-cm proximal to the plafond. A 10mm IMN was then seated and secured with a 60mm interlocking screw, placed in the medial-to-lateral proximal oblique hole. Crossing K-wires were placed in the coronal and sagittal planes to serve as markers for angular and axial displacement. Using fluoroscopic "perfect-circles" technique, three surgeons performed standardized, intentional, eccentric-drilling with proximal-to-distal trajectory. Distal screw placement was performed in the medial-lateral plane, then removed and repeated in the anterior-posterior plane. Coronal and sagittal angulation and axial length were measured by digital goniometer and calipers following screw insertion, respectively. RESULTS: For medial-lateral screws, proximal-to-distal eccentric drilling yielded a mean coronal angulation of 6.0° induced valgus (SD= 3.8°, R:1.5°min-12.2°max). While for anterior-posterior screw placement, proximal-to-distal eccentric drilling yielded a mean of 5.8° procurvatum (SD = 2.0°, R: 2.8°min-8.5°max). Translational distraction in the coronal plane was 3.0mm (SD = 2.2mm, R: 0.05mmmin-7.8mmmax), and distraction in the sagittal plane was 3.9mm (SD = 3.0mm, R: 1.1mmmin,-9.8mmmax). CONCLUSION: Eccentric distal interlocking screw placement produced radiographically appreciable angular and axial changes in distal tibial IMN constructs. Deviations during the "perfect-circles" technique can generate malalignment, or alternatively, be used to fine tune reduction in theory. Precise distal screw trajectory and strategies to minimize drilling eccentricity may reduce postoperative malalignment, particularly in distal tibial fractures. LEVEL OF EVIDENCE: Level V.

Journal of Orthopaedic Trauma
Openalex Percentile: Top 9%
Bone fractures and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.