Native myocardial T1 reference values in a tunisian cohort using MOLLI and SMART1Map

Native T1 values in cardiac magnetic resonance (CMR) are influenced by acquisition sequence, physiological factors, and site-specific variability, complicating clinical interpretation. The absence of population-specific reference values further limits diagnostic accuracy. This study aimed to establish native T1 reference ranges in a Tunisian population, evaluate sex- and age-related differences using MOLLI 5(3)3 and SMART1Map sequences, and assess inter-site variability of MOLLI measurements across two centers using identical scanners and protocols. Ninety-four healthy volunteers were enrolled: 64 subjects (24 females, 40 males; 5-77 years) were scanned at Site 1 to establish reference values, and 30 subjects (20 females, 10 males; 19-62 years), frequency-matched by age to a subset of Site 1, were scanned at Site 2 to evaluate site-related variability. MOLLI-derived T1 values showed a significant negative association with age (β = -0.84 ms/year, p = 0.012), whereas SMART1Map-derived values were not associated with age (β = 0.30 ms/year, p = 0.556). SMART1Map consistently yielded higher T1 values than MOLLI (global mean ± SD: 1184 ± 70 ms vs. 1049 ± 55 ms; p < 0.001). Sex-related differences were minimal, with only a small apical difference observed for MOLLI (p = 0.023). Multi-center MOLLI measurements showed similar T1 distributions across sites, with minor differences observed at the mid-ventricular level. These findings provide the first Tunisian-specific native myocardial T1 reference values at 1.5 T, highlighting sequence-dependent differences, age-related effects for MOLLI, minimal sex-related influence, and overall inter-site consistency. These findings support the use of locally derived, sequence-specific reference ranges to improve clinical interpretation.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-08-14
DOI
https://doi.org/10.1038/s41598-026-47324-w
Primary Topic
Cardiovascular Function and Risk Factors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Native myocardial T1 reference values in a tunisian cohort using MOLLI and SMART1Map

Mariem Dali, Salam Labidi, Wassim Frikha, S. Boukriba et al.
Scientific Reports
Cardiovascular Function and Risk Factors
article

Native myocardial T1 reference values in a tunisian cohort using MOLLI and SMART1Map

Mariem Dali, Salam Labidi, Wassim Frikha, S. Boukriba, Younes Arous, Mohamed Deriche, Hassen Hafsi, Narjes Benameur
article en

Abstract

Native T1 values in cardiac magnetic resonance (CMR) are influenced by acquisition sequence, physiological factors, and site-specific variability, complicating clinical interpretation. The absence of population-specific reference values further limits diagnostic accuracy. This study aimed to establish native T1 reference ranges in a Tunisian population, evaluate sex- and age-related differences using MOLLI 5(3)3 and SMART1Map sequences, and assess inter-site variability of MOLLI measurements across two centers using identical scanners and protocols. Ninety-four healthy volunteers were enrolled: 64 subjects (24 females, 40 males; 5-77 years) were scanned at Site 1 to establish reference values, and 30 subjects (20 females, 10 males; 19-62 years), frequency-matched by age to a subset of Site 1, were scanned at Site 2 to evaluate site-related variability. MOLLI-derived T1 values showed a significant negative association with age (β = -0.84 ms/year, p = 0.012), whereas SMART1Map-derived values were not associated with age (β = 0.30 ms/year, p = 0.556). SMART1Map consistently yielded higher T1 values than MOLLI (global mean ± SD: 1184 ± 70 ms vs. 1049 ± 55 ms; p < 0.001). Sex-related differences were minimal, with only a small apical difference observed for MOLLI (p = 0.023). Multi-center MOLLI measurements showed similar T1 distributions across sites, with minor differences observed at the mid-ventricular level. These findings provide the first Tunisian-specific native myocardial T1 reference values at 1.5 T, highlighting sequence-dependent differences, age-related effects for MOLLI, minimal sex-related influence, and overall inter-site consistency. These findings support the use of locally derived, sequence-specific reference ranges to improve clinical interpretation.

Scientific ReportsVol. 16(1)
Ajman University (AE), City University Ajman (AE), Military Hospital of Tunis (TN), Tunis El Manar University (TN)
Ajman University
Zero hunger
Openalex Percentile: Top 10%
Cardiovascular Function and Risk Factors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.