Solvent-Free Bubbling Extraction Mass Spectrometryfor Ultrasensitive, Size-Independent Detection of Microplastics inWater

Abstract Ultratrace microplastics (MPs) in aquatic environments are a growing problem for ecosystems and human health, yet their reliable detection at subng/L levels with sub-100 nm particle sizes remains a substantial analytical challenge. Herein, we introduce a solvent-free and interface-driven bubbling extraction solid-phase microextraction gas chromatography mass spectrometry (BE−SPME−GC−MS) platform that enables ultrasensitive and size-independent detection of representative MPs (poly(methyl methacrylate) (PMMA), polystyrene (PS), and poly(lactic acid) (PLA)). The method combines bubble bursting−induced aerosol enrichment with the adsorptive microstructures of SPME coatings to achieve a dual solvent-free preconcentration pathway, facilitating the selective release of diagnostic volatile markers (methyl methacrylate, styrene, and lactide). The optimized system achieved limits of detection (LODs) of 80−180 pg/L, which are 3−6 orders of magnitude lower than those of conventional spectroscopic and pyrolysis-based approaches. The method exhibited excellent reproducibility (relative standard deviation <5%) and linearity, with correlation coefficients >0.999 over a broad concentration range. Field application to surface waters in Chengdu revealed MP concentrations below the LODs. Release tests revealed that PS cups exhibit temperature-dependent MP emissions, whereas PLA cups exhibit a nonmonotonic profile characterized by low-temperature brittleness, glass transition behavior, and high-temperature hydrolysis. Overall, this solvent-free, size-independent, and ultrasensitive analytical platform provides a robust tool for elucidating MP release behaviors and assessing real environmental exposure to ultratrace MPs in natural waters.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-08-14
DOI
https://doi.org/10.1021/acs.analchem.6c02800
Primary Topic
Microplastics and Plastic Pollution
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Solvent-Free Bubbling Extraction Mass Spectrometryfor Ultrasensitive, Size-Independent Detection of Microplastics inWater

Yuanji Gao, Yupeng Li, Yuxin Leng, Sining Li et al.
Analytical Chemistry
Microplastics and Plastic Pollution
article

Solvent-Free Bubbling Extraction Mass Spectrometryfor Ultrasensitive, Size-Independent Detection of Microplastics inWater

Yuanji Gao, Yupeng Li, Yuxin Leng, Sining Li, Feng Yuan, Xinyue Li, Yi He, Meiling Liu, Xingyu Li, Min Zhang
article en

Abstract

Abstract Ultratrace microplastics (MPs) in aquatic environments are a growing problem for ecosystems and human health, yet their reliable detection at subng/L levels with sub-100 nm particle sizes remains a substantial analytical challenge. Herein, we introduce a solvent-free and interface-driven bubbling extraction solid-phase microextraction gas chromatography mass spectrometry (BE−SPME−GC−MS) platform that enables ultrasensitive and size-independent detection of representative MPs (poly(methyl methacrylate) (PMMA), polystyrene (PS), and poly(lactic acid) (PLA)). The method combines bubble bursting−induced aerosol enrichment with the adsorptive microstructures of SPME coatings to achieve a dual solvent-free preconcentration pathway, facilitating the selective release of diagnostic volatile markers (methyl methacrylate, styrene, and lactide). The optimized system achieved limits of detection (LODs) of 80−180 pg/L, which are 3−6 orders of magnitude lower than those of conventional spectroscopic and pyrolysis-based approaches. The method exhibited excellent reproducibility (relative standard deviation <5%) and linearity, with correlation coefficients >0.999 over a broad concentration range. Field application to surface waters in Chengdu revealed MP concentrations below the LODs. Release tests revealed that PS cups exhibit temperature-dependent MP emissions, whereas PLA cups exhibit a nonmonotonic profile characterized by low-temperature brittleness, glass transition behavior, and high-temperature hydrolysis. Overall, this solvent-free, size-independent, and ultrasensitive analytical platform provides a robust tool for elucidating MP release behaviors and assessing real environmental exposure to ultratrace MPs in natural waters.

Analytical Chemistry
Sichuan Normal University (CN)
National Natural Science Foundation of China, Sichuan Normal University
Openalex Percentile: Top 20%
Microplastics and Plastic Pollution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.