One-stop head-neck and coronary CT angiography: impact of high-concentration contrast media and low tube voltage on image quality and radiation dose

Abstract Objective To evaluate the combination of high-concentration contrast media (CM) and low tube voltage can reduce radiation dose in one-stop head-neck CT angiography (HNCTA) and coronary CTA (CCTA) without compromising image quality. Methods Patients with or suspected atherosclerosis randomly assigned to four groups. Group A and B underwent conventional-dose (CD) protocols with 320 mg I/ml and 100 kV (HNCTA). Groups C and D underwent low-dose (LD) protocols using 400 mg I/ml and 80 kV (HNCTA). Group A and C with heart-to-cranial sequence, Group B and D with cranial-to-heart sequence. Subjective image quality was independently evaluated by two radiologists. The objective image quality and effective dose (ED) were compared. Results The group D achieved the highest scores on per-patient for one-stop CTA. The LD groups demonstrated comparable background noise, signal-to-noise-ratio (SNR), contrast-to-noise-ratio (CNR) in HNCTA. For CCTA, the LD groups exhibited lower background noise (all p < 0.05). Group C showed higher SNR and CNR in all coronary branches compared to group A ( p < 0.05), except in the aortic root ( p > 0.05). For radiation dose, the group D had the lowest ED (4.13 ± 0.63 mSv, p < 0.001). Conclusion The combination of 80 kV and 400 mg I/ml CM enables effective imaging of the one-stop CTA. The cranial-to-heart sequence in LD protocol may further reduce radiation dose without compromising image quality.

Authors

Institutions

Publication Details

Journal
BMC Medical Imaging
Published
2026-11-04
DOI
https://doi.org/10.1186/s12880-026-02934-8
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

One-stop head-neck and coronary CT angiography: impact of high-concentration contrast media and low tube voltage on image quality and radiation dose

Yi Shan, Ruoyao Cao, Chong Zheng, Shaozhen Yan et al.
3 links
BMC Medical Imaging
Radiation Dose and Imaging
article

One-stop head-neck and coronary CT angiography: impact of high-concentration contrast media and low tube voltage on image quality and radiation dose

Yi Shan, Ruoyao Cao, Chong Zheng, Shaozhen Yan, Jie Lu, Chen Wang, Miao Zhang, Xiaojing Zhao, Yadong Cui, Cheng Zhao
article en

Abstract

Abstract Objective To evaluate the combination of high-concentration contrast media (CM) and low tube voltage can reduce radiation dose in one-stop head-neck CT angiography (HNCTA) and coronary CTA (CCTA) without compromising image quality. Methods Patients with or suspected atherosclerosis randomly assigned to four groups. Group A and B underwent conventional-dose (CD) protocols with 320 mg I/ml and 100 kV (HNCTA). Groups C and D underwent low-dose (LD) protocols using 400 mg I/ml and 80 kV (HNCTA). Group A and C with heart-to-cranial sequence, Group B and D with cranial-to-heart sequence. Subjective image quality was independently evaluated by two radiologists. The objective image quality and effective dose (ED) were compared. Results The group D achieved the highest scores on per-patient for one-stop CTA. The LD groups demonstrated comparable background noise, signal-to-noise-ratio (SNR), contrast-to-noise-ratio (CNR) in HNCTA. For CCTA, the LD groups exhibited lower background noise (all p < 0.05). Group C showed higher SNR and CNR in all coronary branches compared to group A ( p < 0.05), except in the aortic root ( p > 0.05). For radiation dose, the group D had the lowest ED (4.13 ± 0.63 mSv, p < 0.001). Conclusion The combination of 80 kV and 400 mg I/ml CM enables effective imaging of the one-stop CTA. The cranial-to-heart sequence in LD protocol may further reduce radiation dose without compromising image quality.

BMC Medical Imaging
Xuan Wu Hospital of the Capital Medical University (CN)
Good health and well-being
Openalex Percentile: Top 43%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon