Logic-GatedDual-Aptamer Proximity AlphaLISA for Rapidand Sensitive Detection of Tumor-Derived Small Extracellular Vesicles

Abstract Small extracellular vesicles (sEVs) have emerged as promising biomarkers for liquid biopsy; however, the limited specificity of single-marker detection and the intrinsic heterogeneity of circulating sEVs hinder their reliable clinical application. Herein, we develop a programmable dual-aptamer amplified luminescent proximity homogeneous assay (AlphaLISA) for rapid and wash-free detection of tumor-derived sEVs. In this strategy, EpCAM and PD-L1 aptamers simultaneously recognize two membrane proteins on the same vesicle, enabling proximity-induced interaction between donor and acceptor beads to generate a chemiluminescent signal via singlet oxygen-mediated energy transfer. This dual-recognition design effectively improves analytical specificity by implementing a molecular “AND” logic requirement for signal generation. The proposed assay exhibits a broad linear range of 5.3 × 105 to 5.3 × 109 particles mL–1 with a limit of detection of 1.63 × 104 particles mL–1. Good analytical performance was demonstrated by recovery rates of 93.9–107.5% with relative standard deviations below 5%, indicating high accuracy and reproducibility. Notably, the assay enables signal readout within 1 min under homogeneous conditions, highlighting its operational simplicity and rapid response. Clinical applicability was evaluated using serum samples from 20 lung cancer patients and 20 healthy controls, achieving an area under the ROC curve of 0.87 (95% CI: 0.75–0.97), with a sensitivity of 95% and a specificity of 75%. Overall, this programmable dual-aptamer AlphaLISA platform provides a rapid, homogeneous, and highly adaptable strategy for tumor-derived sEVs analysis, offering promising potential for noninvasive cancer diagnostics

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-08-03
DOI
https://doi.org/10.1021/acs.analchem.6c03310
Primary Topic
Extracellular vesicles in disease
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Logic-GatedDual-Aptamer Proximity AlphaLISA for Rapidand Sensitive Detection of Tumor-Derived Small Extracellular Vesicles

Biao Huang, Bing Gu, Yaping Zhang, Yuan Qin et al.
Analytical Chemistry
Extracellular vesicles in disease
article

Logic-GatedDual-Aptamer Proximity AlphaLISA for Rapidand Sensitive Detection of Tumor-Derived Small Extracellular Vesicles

Biao Huang, Bing Gu, Yaping Zhang, Yuan Qin, Hongming Fang, Shangbin Kao, Nannan Tian, Xueqin Zhao
article en

Abstract

Abstract Small extracellular vesicles (sEVs) have emerged as promising biomarkers for liquid biopsy; however, the limited specificity of single-marker detection and the intrinsic heterogeneity of circulating sEVs hinder their reliable clinical application. Herein, we develop a programmable dual-aptamer amplified luminescent proximity homogeneous assay (AlphaLISA) for rapid and wash-free detection of tumor-derived sEVs. In this strategy, EpCAM and PD-L1 aptamers simultaneously recognize two membrane proteins on the same vesicle, enabling proximity-induced interaction between donor and acceptor beads to generate a chemiluminescent signal via singlet oxygen-mediated energy transfer. This dual-recognition design effectively improves analytical specificity by implementing a molecular “AND” logic requirement for signal generation. The proposed assay exhibits a broad linear range of 5.3 × 105 to 5.3 × 109 particles mL–1 with a limit of detection of 1.63 × 104 particles mL–1. Good analytical performance was demonstrated by recovery rates of 93.9–107.5% with relative standard deviations below 5%, indicating high accuracy and reproducibility. Notably, the assay enables signal readout within 1 min under homogeneous conditions, highlighting its operational simplicity and rapid response. Clinical applicability was evaluated using serum samples from 20 lung cancer patients and 20 healthy controls, achieving an area under the ROC curve of 0.87 (95% CI: 0.75–0.97), with a sensitivity of 95% and a specificity of 75%. Overall, this programmable dual-aptamer AlphaLISA platform provides a rapid, homogeneous, and highly adaptable strategy for tumor-derived sEVs analysis, offering promising potential for noninvasive cancer diagnostics

Analytical Chemistry
Zhejiang Chinese Medical University (CN), Zhejiang Sci-Tech University (CN), Hangzhou Normal University (CN), Southern Medical University (CN)
Affordable and clean energy
Openalex Percentile: Top 15%
Extracellular vesicles in disease
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.