Islands of Fractionation for Automated Fractionation Mapping in Epicardial Brugada Syndrome Substrate Ablation

ABSTRACT Introduction Brugada syndrome epicardial RVOT ablation reduces VF, but procedural endpoints remain debated. Automated fractionation maps are often interpreted as scattered points, which may reflect artifacts. Objectives We propose Islands of Fractionation (IOF), a framework comparing EnSite X fractionation count settings against voltage‐defined lesion‐effect reference region. Methods This case series included six Brugada syndrome patients undergoing epicardial substrate ablation. Mapping was performed in sinus rhythm using EnSite X with an Advisor HD Grid catheter. Automated fractionation maps were generated with the EnSite X CFE‐count algorithm using refractory settings of 14 and 20 ms. Abnormal points were defined as fractionation count ≥3; lesion‐effect reference region was defined by voltage change (pre >0.5 mV, post <0.3 mV). Island overlap was quantified using DBSCAN clustering and mesh‐based area estimation. Results IOF revealed a consistent coverage–parsimony trade‐off between refractory settings. The 14‐ms setting produced broader islands with higher reference‐region coverage (median overlap 84.6% [IQR 80.8–93.7]) but larger extraneous mapped area (up to 72.9 cm 2 ). The 20‐ms setting produced more compact islands with markedly reduced extraneous area (0.0–34.8 cm 2 ) but lower coverage (59.9% [IQR 37.2–74.7]). In parallel, fractionation burden within the ablated region decreased substantially after ablation in both settings (median total burden reduction 86% vs 93%), supporting lesion‐effect concordance of automated fractionation metrics. Conclusion IOF provides an island‐based framework for interpreting automated fractionation mapping and describing its spatial concordance with lesion‐effect regions. In this retrospective series, 14 ms favored broader coverage, whereas 20 ms favored greater parsimony.

Authors

Institutions

Publication Details

Journal
Pacing and Clinical Electrophysiology
Published
2026-08-03
DOI
https://doi.org/10.1111/pace.70382
Primary Topic
Cardiac electrophysiology and arrhythmias
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Islands of Fractionation for Automated Fractionation Mapping in Epicardial Brugada Syndrome Substrate Ablation

Shih‐Lin Chang, Khuong Dang Tran, Danica Ann Leycano, Cheng-Han Chan et al.
Pacing and Clinical Electrophysiology
Cardiac electrophysiology and arrhythmias
article

Islands of Fractionation for Automated Fractionation Mapping in Epicardial Brugada Syndrome Substrate Ablation

Shih‐Lin Chang, Khuong Dang Tran, Danica Ann Leycano, Cheng-Han Chan, Ting‐Yung Chang, Ling Kuo, Chih‐Min Liu, Li Wei Lo, Arlene Melissa T. Dychiching, Yat Yu Cheung, Chin‐Yu Lin, Cheng I. Wu, Ding Jun Juan, Lo Chieh Ling
article en

Abstract

ABSTRACT Introduction Brugada syndrome epicardial RVOT ablation reduces VF, but procedural endpoints remain debated. Automated fractionation maps are often interpreted as scattered points, which may reflect artifacts. Objectives We propose Islands of Fractionation (IOF), a framework comparing EnSite X fractionation count settings against voltage‐defined lesion‐effect reference region. Methods This case series included six Brugada syndrome patients undergoing epicardial substrate ablation. Mapping was performed in sinus rhythm using EnSite X with an Advisor HD Grid catheter. Automated fractionation maps were generated with the EnSite X CFE‐count algorithm using refractory settings of 14 and 20 ms. Abnormal points were defined as fractionation count ≥3; lesion‐effect reference region was defined by voltage change (pre >0.5 mV, post <0.3 mV). Island overlap was quantified using DBSCAN clustering and mesh‐based area estimation. Results IOF revealed a consistent coverage–parsimony trade‐off between refractory settings. The 14‐ms setting produced broader islands with higher reference‐region coverage (median overlap 84.6% [IQR 80.8–93.7]) but larger extraneous mapped area (up to 72.9 cm 2 ). The 20‐ms setting produced more compact islands with markedly reduced extraneous area (0.0–34.8 cm 2 ) but lower coverage (59.9% [IQR 37.2–74.7]). In parallel, fractionation burden within the ablated region decreased substantially after ablation in both settings (median total burden reduction 86% vs 93%), supporting lesion‐effect concordance of automated fractionation metrics. Conclusion IOF provides an island‐based framework for interpreting automated fractionation mapping and describing its spatial concordance with lesion‐effect regions. In this retrospective series, 14 ms favored broader coverage, whereas 20 ms favored greater parsimony.

Pacing and Clinical Electrophysiology
National Yang Ming Chiao Tung University (TW), Taipei Veterans General Hospital (TW)
Life below water
Openalex Percentile: Top 9%
Cardiac electrophysiology and arrhythmias
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.