Development and validation of a sensitive HPLC-MS/MS method for the analysis of semaglutide in human plasma

BACKGROUND: Semaglutide is a human glucagon-like peptide-1 (GLP-1) peptide analog. To date, the literature does not report a validated HPLC-MS/MS assay using a triple-quadrupole mass spectrometer for the quantitation of semaglutide in human plasma in support of pharmacokinetics. A robust, sensitive HPLC--MS/MS assay supporting this class of compounds, is provided and full validation demonstrated. METHODS AND RESULTS: A triple-quadrupole HPLC-MS/MS method has been developed and fully validated for the quantitation of semaglutide in human plasma, using a stable isotope labeled internal standard and an effective, efficient protein precipitation sample extraction. The method has a sensitive analytical range of 5 ng/mL to 200 ng/mL (and to 1000 ng/mL with a dilution QC) and exhibits excellent accuracy (92.7% to 109.4%) and precision of <10.6%. This highly selective method provided high recovery of the analyte, with minimal matrix effects. CONCLUSION: A robust and simple HPLC-MS/MS method to quantify semaglutide in human plasma has been fully validated in accordance with the 2022 FDA M10 guidance. This method is suitable for implementation in clinical studies within the validated analytical range and stability conditions and can be extended to the bioanalysis of other GLP-1 peptide-based therapeutics with similar structural and physiochemical properties.

Authors

Institutions

Publication Details

Journal
Bioanalysis
Published
2026-08-03
DOI
https://doi.org/10.1080/17576180.2026.2712160
Primary Topic
Diabetes Treatment and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and validation of a sensitive HPLC-MS/MS method for the analysis of semaglutide in human plasma

Christopher Tudan, Lauren Devine, Emily Northwick Darden, Joel Stickling et al.
Bioanalysis
Diabetes Treatment and Management
article

Development and validation of a sensitive HPLC-MS/MS method for the analysis of semaglutide in human plasma

Christopher Tudan, Lauren Devine, Emily Northwick Darden, Joel Stickling, Shane Needham
article en

Abstract

BACKGROUND: Semaglutide is a human glucagon-like peptide-1 (GLP-1) peptide analog. To date, the literature does not report a validated HPLC-MS/MS assay using a triple-quadrupole mass spectrometer for the quantitation of semaglutide in human plasma in support of pharmacokinetics. A robust, sensitive HPLC--MS/MS assay supporting this class of compounds, is provided and full validation demonstrated. METHODS AND RESULTS: A triple-quadrupole HPLC-MS/MS method has been developed and fully validated for the quantitation of semaglutide in human plasma, using a stable isotope labeled internal standard and an effective, efficient protein precipitation sample extraction. The method has a sensitive analytical range of 5 ng/mL to 200 ng/mL (and to 1000 ng/mL with a dilution QC) and exhibits excellent accuracy (92.7% to 109.4%) and precision of <10.6%. This highly selective method provided high recovery of the analyte, with minimal matrix effects. CONCLUSION: A robust and simple HPLC-MS/MS method to quantify semaglutide in human plasma has been fully validated in accordance with the 2022 FDA M10 guidance. This method is suitable for implementation in clinical studies within the validated analytical range and stability conditions and can be extended to the bioanalysis of other GLP-1 peptide-based therapeutics with similar structural and physiochemical properties.

Bioanalysis
Velocity Clinical Research (United States) (US)
Openalex Percentile: Top 9%
Diabetes Treatment and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development and validation of a sensitive HPLC-MS/MS method for the analysis of semaglutide in human plasma — Christopher Tudan, Lauren Devine, et al. · Bioanalysis (2026) | TGRS Research Map | TGRS