Comparison of 3‐Dimensional Ultrasound and Computed Tomography for Imaging of Abdominal Aortic Aneurysms

OBJECTIVES: Three-dimensional ultrasound (3D US) is emerging as a novel imaging method for abdominal aortic aneurysms (AAAs) as it creates a low-cost 3D AAA overview without harmful radiation and nephrotoxic contrast agents, as opposed to conventional imaging. 3D US can be used with a non-nephrotoxic contrast agent (3D-CEUS) for lumen delineation. This study aims to compare 3D US and 3D-CEUS using a commercially available 3D US system against contrast-enhanced computed tomography (CTA). METHODS: For twenty AAA patients, the total AAA was segmented for all 3 modalities, and the lumen was segmented in the 3D-CEUS and CTA scans. The CTA segmentations were registered onto each 3D (CE)US segmentation, and evaluation metrics were computed, including the volumes, average surface distance, sensitivity, precision, and Dice score. RESULTS: 3D US and 3D-CEUS scans were feasible in all patients. Lumen volumes were significantly larger on 3D-CEUS compared to CTA (94 versus 70 mL, p < .001). The total AAA volumes were significantly smaller on 3D US compared to CTA (142 versus 165 mL, p = .002), and comparable on 3D-CEUS (176 versus 165 mL, p = .433). The Dice scores were overall acceptable, ranging from 0.82 to 0.88, and the average surface distances were 2.5 mm. CONCLUSIONS: This study demonstrated the feasibility of 3D US and 3D-CEUS for AAA imaging with good correspondence to CTA. Addition of the contrast agent increased agreement of volume measurements. 3D US facilitated retrospective offline AAA assessment, which is a major added value compared to 2D US. For now, 3D US already seems a promising imaging modality, which has to be proven in a large-scale study.

Authors

Institutions

Publication Details

Journal
Journal of Ultrasound in Medicine
Published
2026-08-03
DOI
https://doi.org/10.1002/jum.70399
Primary Topic
Aortic aneurysm repair treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of 3‐Dimensional Ultrasound and Computed Tomography for Imaging of Abdominal Aortic Aneurysms

Jelmer M. Wolterink, Michel M.P.J. Reijnen, Erik Groot Jebbink, R E van Rijswijk et al.
Journal of Ultrasound in Medicine
Aortic aneurysm repair treatments
article

Comparison of 3‐Dimensional Ultrasound and Computed Tomography for Imaging of Abdominal Aortic Aneurysms

Jelmer M. Wolterink, Michel M.P.J. Reijnen, Erik Groot Jebbink, R E van Rijswijk, Suzan R.T. Everink, Heleen S. van Nie
article en

Abstract

OBJECTIVES: Three-dimensional ultrasound (3D US) is emerging as a novel imaging method for abdominal aortic aneurysms (AAAs) as it creates a low-cost 3D AAA overview without harmful radiation and nephrotoxic contrast agents, as opposed to conventional imaging. 3D US can be used with a non-nephrotoxic contrast agent (3D-CEUS) for lumen delineation. This study aims to compare 3D US and 3D-CEUS using a commercially available 3D US system against contrast-enhanced computed tomography (CTA). METHODS: For twenty AAA patients, the total AAA was segmented for all 3 modalities, and the lumen was segmented in the 3D-CEUS and CTA scans. The CTA segmentations were registered onto each 3D (CE)US segmentation, and evaluation metrics were computed, including the volumes, average surface distance, sensitivity, precision, and Dice score. RESULTS: 3D US and 3D-CEUS scans were feasible in all patients. Lumen volumes were significantly larger on 3D-CEUS compared to CTA (94 versus 70 mL, p < .001). The total AAA volumes were significantly smaller on 3D US compared to CTA (142 versus 165 mL, p = .002), and comparable on 3D-CEUS (176 versus 165 mL, p = .433). The Dice scores were overall acceptable, ranging from 0.82 to 0.88, and the average surface distances were 2.5 mm. CONCLUSIONS: This study demonstrated the feasibility of 3D US and 3D-CEUS for AAA imaging with good correspondence to CTA. Addition of the contrast agent increased agreement of volume measurements. 3D US facilitated retrospective offline AAA assessment, which is a major added value compared to 2D US. For now, 3D US already seems a promising imaging modality, which has to be proven in a large-scale study.

Journal of Ultrasound in Medicine
Rijnstate Hospital (NL), University of Twente (NL)
Stichting Lijf en Leven
Openalex Percentile: Top 10%
Aortic aneurysm repair treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.