Design and Experimental Field Mapping of Merritt Coil System for Polarized 3He Precision Measurements

Highly polarized 3He is widely used in precision magnetometry, neutron spin filtering, and fundamental symmetry tests, where magnetic field gradients can shorten relaxation and coherence times and introduce systematic uncertainties. We present the design, modeling, and experimental characterization of a compact four-square-coil Merritt system developed to provide a uniform holding field for precision measurements of polarized 3He. The magnetic field is calculated directly from analytical vector potentials and analyzed using a near-center expansion. By combining Maxwell’s equations with the spatial symmetries of square- and circular-coil systems, we show that the dominant second-order transverse gradients within the small central cell volume are determined by the axial curvature of Bz. The relevant gradient performance can therefore be characterized using a single axial scan, without routine complete three-dimensional mapping. The calculated performance of the Merritt configuration is quantitatively compared with that of the Helmholtz, Lee–Whiting, and Garrett systems. A prototype is constructed and measured using a three-axis fluxgate magnetometer mounted on a motorized translation stage.The measured axial field agrees well with the calculated profile, and the normalized magnetic field gradient in the central 10 cm region is below 10−4 cm−1. This region fully covers the cylindrical 3He cell, whose diameter and length are both no greater than 5 cm. The Merritt configuration therefore provides a practical compromise between gradient suppression, compactness, optical access, and mechanical simplicity for polarized noble- gas sensors and precision measurements.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-08-03
DOI
https://doi.org/10.3390/s26154898
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Experimental Field Mapping of Merritt Coil System for Polarized 3He Precision Measurements

温若云, H. Yan, Chaoyang Zhao
Sensors
Atomic and Subatomic Physics Research
article

Design and Experimental Field Mapping of Merritt Coil System for Polarized 3He Precision Measurements

温若云, H. Yan, Chaoyang Zhao
article en

Abstract

Highly polarized 3He is widely used in precision magnetometry, neutron spin filtering, and fundamental symmetry tests, where magnetic field gradients can shorten relaxation and coherence times and introduce systematic uncertainties. We present the design, modeling, and experimental characterization of a compact four-square-coil Merritt system developed to provide a uniform holding field for precision measurements of polarized 3He. The magnetic field is calculated directly from analytical vector potentials and analyzed using a near-center expansion. By combining Maxwell’s equations with the spatial symmetries of square- and circular-coil systems, we show that the dominant second-order transverse gradients within the small central cell volume are determined by the axial curvature of Bz. The relevant gradient performance can therefore be characterized using a single axial scan, without routine complete three-dimensional mapping. The calculated performance of the Merritt configuration is quantitatively compared with that of the Helmholtz, Lee–Whiting, and Garrett systems. A prototype is constructed and measured using a three-axis fluxgate magnetometer mounted on a motorized translation stage.The measured axial field agrees well with the calculated profile, and the normalized magnetic field gradient in the central 10 cm region is below 10−4 cm−1. This region fully covers the cylindrical 3He cell, whose diameter and length are both no greater than 5 cm. The Merritt configuration therefore provides a practical compromise between gradient suppression, compactness, optical access, and mechanical simplicity for polarized noble- gas sensors and precision measurements.

SensorsVol. 26(15)
Ningbo University of Technology (CN), Sichuan University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 11%
Atomic and Subatomic Physics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.