Serum PFAS levels in UK firefighters

Per- and polyfluoroalkyl substances (PFAS) represent an emerging concern due to their persistence, bioaccumulation, and emerging associations with different cancers and other diseases. Biomonitoring studies worldwide report elevated PFAS serum concentrations in firefighters compared with other occupations and the general population. The aim of this study was to quantify PFAS serum concentration in current and former firefighters and a general population comparison group in the UK. PFAS serum concentrations were analysed in a total sample of 1224 participants, including 942 firefighters from eight Fire and Rescue Services (FRSs) and 282 individuals from the general population. PFAS concentrations varied across tested FRSs, with geometric mean serum levels for some analytes higher than those observed in the general population. These included PFHxS (4.1 times higher), PFOS sum (1.5 times higher) and PFHPS (about 1.6 times higher), compounds that have been historically associated with the use of aqueous film forming firefighting foams. Furthermore, four PFAS (8:2 FTS, FOSA, PFBS, and PFPeS) were detected exclusively in firefighter serum and not in the general population, of which three are commonly detected in firefighter turnout gear. Descriptively, PFAS geometric mean concentrations tended to be higher among older firefighters and those with longer service duration. The general population cohort, drawn from a region which has subsequently been found to have some of the UK's highest PFAS environmental contamination, showed relatively high baseline serum PFAS levels, suggesting the contribution of high background environmental exposure in this cohort. Reported data highlights the need for PFAS monitoring among firefighters, including evaluation of occupational exposure pathways, with attention to likely sources such as firefighting foam types and formulations; the type of chemicals applied to turnout gear; PPE use, frequency and type of decontamination. Further research should also include wider monitoring of the general population, including evaluation of likely sources and pathways of exposure.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-08-03
DOI
https://doi.org/10.1038/s41598-026-58059-z
Primary Topic
Per- and polyfluoroalkyl substances research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Serum PFAS levels in UK firefighters

Matthew Gittins, Anna A. Stec, Katarina Handlovicova, Kathryn Riley et al.
Scientific Reports
Per- and polyfluoroalkyl substances research
article

Serum PFAS levels in UK firefighters

Matthew Gittins, Anna A. Stec, Katarina Handlovicova, Kathryn Riley, Thomas Snelgrove, Colin C. Everett
article en

Abstract

Per- and polyfluoroalkyl substances (PFAS) represent an emerging concern due to their persistence, bioaccumulation, and emerging associations with different cancers and other diseases. Biomonitoring studies worldwide report elevated PFAS serum concentrations in firefighters compared with other occupations and the general population. The aim of this study was to quantify PFAS serum concentration in current and former firefighters and a general population comparison group in the UK. PFAS serum concentrations were analysed in a total sample of 1224 participants, including 942 firefighters from eight Fire and Rescue Services (FRSs) and 282 individuals from the general population. PFAS concentrations varied across tested FRSs, with geometric mean serum levels for some analytes higher than those observed in the general population. These included PFHxS (4.1 times higher), PFOS sum (1.5 times higher) and PFHPS (about 1.6 times higher), compounds that have been historically associated with the use of aqueous film forming firefighting foams. Furthermore, four PFAS (8:2 FTS, FOSA, PFBS, and PFPeS) were detected exclusively in firefighter serum and not in the general population, of which three are commonly detected in firefighter turnout gear. Descriptively, PFAS geometric mean concentrations tended to be higher among older firefighters and those with longer service duration. The general population cohort, drawn from a region which has subsequently been found to have some of the UK's highest PFAS environmental contamination, showed relatively high baseline serum PFAS levels, suggesting the contribution of high background environmental exposure in this cohort. Reported data highlights the need for PFAS monitoring among firefighters, including evaluation of occupational exposure pathways, with attention to likely sources such as firefighting foam types and formulations; the type of chemicals applied to turnout gear; PPE use, frequency and type of decontamination. Further research should also include wider monitoring of the general population, including evaluation of likely sources and pathways of exposure.

Scientific ReportsVol. 16(1)
University of Lancashire (GB), Manchester Academic Health Science Centre (GB), University of Manchester (GB)
Openalex Percentile: Top 16%
Per- and polyfluoroalkyl substances research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.