Charred Wood Cladding System Reaction to Fire: Influence of Wood Type, Surface Covering and Coating

This study investigates the reaction of charred wood cladding systems to fire, focusing on the influence of wood species, charred surface treatment, flame retardant treatment, surface coating and board orientation. Nine different configurations of larch and spruce cladding samples with 20 mm thickness were investigated, which were installed into the system according to standard requirements. The samples differed by wood type, charred surface treatment, board orientation, covering with flame retardant agents and additional surface coverings. Two commercial flame retardant treatments and three commercial surface coatings were included in the experimental matrix. Fire behaviour was evaluated according to the EN 13823 Single Burning Item (SBI) method, analysing the ignition time, fire growth rate index, total heat release from the specimen in the first 600 s of exposure to the main burner flames, smoke growth rate index and total smoke production from the specimen in the first 600 s of exposure to the main burner flames as indicators. Although it was determined that the ignition time fluctuated in a relatively narrow range (from 5 min 12 s to 5 min 36 s), analyses of the additional SBI indicators revealed much clearer differences between the systems. The best results were obtained for the charred notched spruce system treated with the phosphate-, urea- and biocide-based flame retardant, which had the longest ignition time and lowest values for the investigated indicators. Meanwhile, the least favourable behaviour was observed in the notched untreated spruce system and in the horizontally oriented system, marked by higher fire spreading and smoke formation values. The obtained results show that the reaction of a wood cladding system to fire is not determined only by the type or application rate of flame retardant, but also the whole system’s structure, including the wood type, surface processing, covering combination and installation configuration.

Authors

Institutions

Publication Details

Journal
Fire
Published
2026-08-03
DOI
https://doi.org/10.3390/fire9080323
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Charred Wood Cladding System Reaction to Fire: Influence of Wood Type, Surface Covering and Coating

Mindaugas Grigonis, Ramunė Žurauskienė, Liudas Sukevicius
Fire
Fire dynamics and safety research
article

Charred Wood Cladding System Reaction to Fire: Influence of Wood Type, Surface Covering and Coating

Mindaugas Grigonis, Ramunė Žurauskienė, Liudas Sukevicius
article en

Abstract

This study investigates the reaction of charred wood cladding systems to fire, focusing on the influence of wood species, charred surface treatment, flame retardant treatment, surface coating and board orientation. Nine different configurations of larch and spruce cladding samples with 20 mm thickness were investigated, which were installed into the system according to standard requirements. The samples differed by wood type, charred surface treatment, board orientation, covering with flame retardant agents and additional surface coverings. Two commercial flame retardant treatments and three commercial surface coatings were included in the experimental matrix. Fire behaviour was evaluated according to the EN 13823 Single Burning Item (SBI) method, analysing the ignition time, fire growth rate index, total heat release from the specimen in the first 600 s of exposure to the main burner flames, smoke growth rate index and total smoke production from the specimen in the first 600 s of exposure to the main burner flames as indicators. Although it was determined that the ignition time fluctuated in a relatively narrow range (from 5 min 12 s to 5 min 36 s), analyses of the additional SBI indicators revealed much clearer differences between the systems. The best results were obtained for the charred notched spruce system treated with the phosphate-, urea- and biocide-based flame retardant, which had the longest ignition time and lowest values for the investigated indicators. Meanwhile, the least favourable behaviour was observed in the notched untreated spruce system and in the horizontally oriented system, marked by higher fire spreading and smoke formation values. The obtained results show that the reaction of a wood cladding system to fire is not determined only by the type or application rate of flame retardant, but also the whole system’s structure, including the wood type, surface processing, covering combination and installation configuration.

FireVol. 9(8)
Vilnius Gediminas Technical University (LT)
Openalex Percentile: Top 10%
Fire dynamics and safety research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.