Feasibility and outcomes of catheter ablation using robotic magnetic navigation in patients with congenital heart disease with varying defect complexity

Introduction Robotic magnetic navigation (RMN) allows for catheter ablation in the presence of complex cardiac anatomy, such as that seen in congenital heart disease (CHD). The objective of this study was to evaluate the feasibility, efficacy and safety of this procedure in a wide range of CHD conditions. Methods Patients with CHD who underwent catheter ablation for cardiac arrhythmias using RMN were included in this single-centre observational study. Patients’ baseline characteristics, procedural data, periprocedural complications and acute success rates were obtained. The efficacy of the ablation was evaluated during follow-up in the outpatient clinic using 24-h Holter monitoring. Results The study population consisted of 38 patients (26 males) with a median age of 36.8 (IQR 30.8-39.6) years. Surgically corrected transposition of the great arteries was the most common CHD, observed in 14 patients (36.8%). Nineteen patients (50.0%) had more than one congenital defect. Intra-atrial re-entrant tachycardia was the most common arrhythmia ablated, accounting for 21 procedures (55.3%). Median procedural time was 232.5 min (IQR 186.3-281.3); the median radiation dose and radiation time were 2.4 mGy m 2 (IQR 1.3-4.4) and 14.0 min (IQR 9.5-30.4), respectively. Acute arrhythmia cessation was observed in 81.6% of procedures. Major complications were noted in 2 cases (5.3%). The median time from the ablation to follow-up was 5.4 months (IQR 3.4-9.3). Arrhythmia recurrence was observed in 7 cases (18.4%). Conclusions RMN is a valuable tool for catheter ablation of arrhythmias in patients with congenital heart disease and complex anatomy.

Authors

Institutions

Publication Details

Journal
International Journal of Cardiology Congenital Heart Disease
Published
2026-08-03
DOI
https://doi.org/10.1016/j.ijcchd.2026.100697
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility and outcomes of catheter ablation using robotic magnetic navigation in patients with congenital heart disease with varying defect complexity

Grzegorz Warmiński, Robert Bodalski, Maria Bilińska, Filip Machaj et al.
International Journal of Cardiology Congenital Heart Disease
Cardiac Arrhythmias and Treatments
article

Feasibility and outcomes of catheter ablation using robotic magnetic navigation in patients with congenital heart disease with varying defect complexity

Grzegorz Warmiński, Robert Bodalski, Maria Bilińska, Filip Machaj, Ewa Warchoł-Celińska, Andrzej Hasiec, Piotr Urbanek, Łukasz Szumowski, Maciej Sterliński, Jakub Malinowski, Mirosław Kowalski, Michał Orczykowski, Magdalena Lipczyńska
article en

Abstract

Introduction Robotic magnetic navigation (RMN) allows for catheter ablation in the presence of complex cardiac anatomy, such as that seen in congenital heart disease (CHD). The objective of this study was to evaluate the feasibility, efficacy and safety of this procedure in a wide range of CHD conditions. Methods Patients with CHD who underwent catheter ablation for cardiac arrhythmias using RMN were included in this single-centre observational study. Patients’ baseline characteristics, procedural data, periprocedural complications and acute success rates were obtained. The efficacy of the ablation was evaluated during follow-up in the outpatient clinic using 24-h Holter monitoring. Results The study population consisted of 38 patients (26 males) with a median age of 36.8 (IQR 30.8-39.6) years. Surgically corrected transposition of the great arteries was the most common CHD, observed in 14 patients (36.8%). Nineteen patients (50.0%) had more than one congenital defect. Intra-atrial re-entrant tachycardia was the most common arrhythmia ablated, accounting for 21 procedures (55.3%). Median procedural time was 232.5 min (IQR 186.3-281.3); the median radiation dose and radiation time were 2.4 mGy m 2 (IQR 1.3-4.4) and 14.0 min (IQR 9.5-30.4), respectively. Acute arrhythmia cessation was observed in 81.6% of procedures. Major complications were noted in 2 cases (5.3%). The median time from the ablation to follow-up was 5.4 months (IQR 3.4-9.3). Arrhythmia recurrence was observed in 7 cases (18.4%). Conclusions RMN is a valuable tool for catheter ablation of arrhythmias in patients with congenital heart disease and complex anatomy.

International Journal of Cardiology Congenital Heart DiseaseVol. 25
Medical University of Warsaw (PL), The Arrhythmia Institute (US), Institute of Cardiology (PL), Narodowy Instytut Leków (PL)
Agencja Badań Medycznych
Good health and well-being
Openalex Percentile: Top 9%
Cardiac Arrhythmias and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.