Axial Behaviour of Reinforced Concrete Columns Strengthened with Self-Compacting Geopolymer Concrete Jacketing and External FRP Confinement

The structural performance of reinforced concrete (RC) columns can be substantially improved by using advanced confinement systems and sustainable cementitious materials. This study presents an integrated experimental, numerical, and analytical investigation of RC columns strengthened with self-compacting geopolymer concrete (SCGC) and carbon fiber-reinforced polymer (CFRP) under axial compression. Twelve column specimens were tested across four groups: conventional RC columns, unconfined SCGC columns, SCGC-jacketed columns (CONF. SCGC), and CFRP-wrapped columns (CONF. FRP), in three cross-sectional geometries: square (177 × 177 mm), rectangular (265 × 177 mm), and circular (Ø200 mm). Experimental results demonstrated that replacing conventional concrete with SCGC improved deformation capacity, increasing the ultimate axial displacement from 2.07 mm in the reference square RC column (RC C1) to 3.21 mm in the corresponding square SCGC specimen (SCGC C1). On a normalized stress basis, the unconfined SCGC specimens achieved ultimate axial stress values of 56–64 MPa compared to 41–49 MPa for the RC reference columns of the same geometry, representing material-level strength gains of 1.30–1.49×. The application of external confinement further enhanced column behaviour. The CFRP-wrapped specimens achieved the highest material-level strength efficiency, with normalized ultimate axial stress values of 98–108 MPa for the square and rectangular geometries, representing gains of 2.01–2.41× over the corresponding unconfined RC columns of identical cross-section. The SCGC-jacketed specimens achieved the highest absolute load capacities, with CONF. SCGC C2 reaching 8270 kN and a maximum stiffness of 5531 kN/mm and energy absorption of 19,740 kN·mm. However, on a normalized stress basis, the SCGC-jacketed square and rectangular specimens achieved 45–47 MPa, comparable to the RC reference columns, confirming that their absolute load gains are primarily attributable to section enlargement rather than intrinsic material strength enhancement. The circular SCGC-jacketed specimen achieved a normalized stress of 43 MPa, consistent with the same trend. A three-dimensional nonlinear finite element model developed in ABAQUS using the Concrete Damaged Plasticity model and cohesive zone interactions showed close agreement with experimental results, with mean prediction ratios of 1.03 for ultimate load and 0.96 for displacement. An analytical model provided conservative estimates of axial capacity. The findings demonstrate that CFRP wrapping offers superior material-level confinement efficiency, while SCGC jacketing provides the highest absolute load capacity through combined section enlargement and passive confinement, representing a potentially more environmentally friendly strengthening strategy for existing RC columns.

Authors

Institutions

Publication Details

Journal
Infrastructures
Published
2026-08-03
DOI
https://doi.org/10.3390/infrastructures11080272
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Axial Behaviour of Reinforced Concrete Columns Strengthened with Self-Compacting Geopolymer Concrete Jacketing and External FRP Confinement

Ahmed M. Tahwia, Mohamed Mortagi, Osama Youssf, Talal Athobaiti
Infrastructures
Structural Behavior of Reinforced Concrete
article

Axial Behaviour of Reinforced Concrete Columns Strengthened with Self-Compacting Geopolymer Concrete Jacketing and External FRP Confinement

Ahmed M. Tahwia, Mohamed Mortagi, Osama Youssf, Talal Athobaiti
article en

Abstract

The structural performance of reinforced concrete (RC) columns can be substantially improved by using advanced confinement systems and sustainable cementitious materials. This study presents an integrated experimental, numerical, and analytical investigation of RC columns strengthened with self-compacting geopolymer concrete (SCGC) and carbon fiber-reinforced polymer (CFRP) under axial compression. Twelve column specimens were tested across four groups: conventional RC columns, unconfined SCGC columns, SCGC-jacketed columns (CONF. SCGC), and CFRP-wrapped columns (CONF. FRP), in three cross-sectional geometries: square (177 × 177 mm), rectangular (265 × 177 mm), and circular (Ø200 mm). Experimental results demonstrated that replacing conventional concrete with SCGC improved deformation capacity, increasing the ultimate axial displacement from 2.07 mm in the reference square RC column (RC C1) to 3.21 mm in the corresponding square SCGC specimen (SCGC C1). On a normalized stress basis, the unconfined SCGC specimens achieved ultimate axial stress values of 56–64 MPa compared to 41–49 MPa for the RC reference columns of the same geometry, representing material-level strength gains of 1.30–1.49×. The application of external confinement further enhanced column behaviour. The CFRP-wrapped specimens achieved the highest material-level strength efficiency, with normalized ultimate axial stress values of 98–108 MPa for the square and rectangular geometries, representing gains of 2.01–2.41× over the corresponding unconfined RC columns of identical cross-section. The SCGC-jacketed specimens achieved the highest absolute load capacities, with CONF. SCGC C2 reaching 8270 kN and a maximum stiffness of 5531 kN/mm and energy absorption of 19,740 kN·mm. However, on a normalized stress basis, the SCGC-jacketed square and rectangular specimens achieved 45–47 MPa, comparable to the RC reference columns, confirming that their absolute load gains are primarily attributable to section enlargement rather than intrinsic material strength enhancement. The circular SCGC-jacketed specimen achieved a normalized stress of 43 MPa, consistent with the same trend. A three-dimensional nonlinear finite element model developed in ABAQUS using the Concrete Damaged Plasticity model and cohesive zone interactions showed close agreement with experimental results, with mean prediction ratios of 1.03 for ultimate load and 0.96 for displacement. An analytical model provided conservative estimates of axial capacity. The findings demonstrate that CFRP wrapping offers superior material-level confinement efficiency, while SCGC jacketing provides the highest absolute load capacity through combined section enlargement and passive confinement, representing a potentially more environmentally friendly strengthening strategy for existing RC columns.

InfrastructuresVol. 11(8)
Mansoura University (EG), Taif University (SA), United Arab Emirates University (AE)
Openalex Percentile: Top 12%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.