Automatic sleep staging and atonia detection in RBD using single-channel chin EMG

Study ObjectivesThe diagnosis of rapid eye movement (REM) sleep behavior disorder (RBD) is of clinical interest, as there is a high rate of future conversion to Parkinson's disease and related neurodegenerative disorders. The clinical standard for diagnosis of RBD relies on human scoring of REM sleep without atonia (RSWA) via polysomnography, which is labor-intensive, costly, and unsuitable for long-term monitoring. Existing (semi-)automatic detection methods often depend on prior manual annotation of REM or suffer from low REM classification performance in this population. We here propose a fully automated system using only a single-channel chin electromyography (EMG) for both REM scoring and RSWA quantification.MethodsWe analyzed 485 polysomnographic recordings, including 30 recordings of subjects with RBD. Using the recently introduced factorized score-based diffusion model, we automatically scored REM epochs based on single-channel chin EMG data, and subsequently quantified RSWA using the REM atonia index from literature.ResultsThe proposed system demonstrated strong performance in REM scoring in both subjects with and without RBD (REM sensitivity ≥0.80, specificity ≥0.97, positive predictive value ≥0.81). The REM atonia index derived from automatic scoring showed strong agreement with manually scored data, with minimal bias (≤0.03), narrow limits of agreement (≤0.13), and strong linear correlation (Peason's r ≥ 0.88).ConclusionsFully automated RSWA quantification using single-channel chin EMG is feasible and performs comparable to semi-automatic methods that rely on human sleep stage scoring based on polysomnography. This single-sensor approach can improve RBD screening accessibility, particularly in ambulatory settings, and facilitate long term monitoring of RSWA.

Authors

Institutions

Publication Details

Journal
Journal of Parkinson s Disease
Published
2026-08-03
DOI
https://doi.org/10.1177/1877718x261468531
Primary Topic
Sleep and Wakefulness Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automatic sleep staging and atonia detection in RBD using single-channel chin EMG

Hans van Gorp, Angelique Pijpers, Merel M. van Gilst, Sebastiaan Overeem et al.
Journal of Parkinson s Disease
Sleep and Wakefulness Research
article

Automatic sleep staging and atonia detection in RBD using single-channel chin EMG

Hans van Gorp, Angelique Pijpers, Merel M. van Gilst, Sebastiaan Overeem, Jaap F. van der Aar, Pedro Fonseca, Ruud JG van Sloun
article en

Abstract

Study ObjectivesThe diagnosis of rapid eye movement (REM) sleep behavior disorder (RBD) is of clinical interest, as there is a high rate of future conversion to Parkinson's disease and related neurodegenerative disorders. The clinical standard for diagnosis of RBD relies on human scoring of REM sleep without atonia (RSWA) via polysomnography, which is labor-intensive, costly, and unsuitable for long-term monitoring. Existing (semi-)automatic detection methods often depend on prior manual annotation of REM or suffer from low REM classification performance in this population. We here propose a fully automated system using only a single-channel chin electromyography (EMG) for both REM scoring and RSWA quantification.MethodsWe analyzed 485 polysomnographic recordings, including 30 recordings of subjects with RBD. Using the recently introduced factorized score-based diffusion model, we automatically scored REM epochs based on single-channel chin EMG data, and subsequently quantified RSWA using the REM atonia index from literature.ResultsThe proposed system demonstrated strong performance in REM scoring in both subjects with and without RBD (REM sensitivity ≥0.80, specificity ≥0.97, positive predictive value ≥0.81). The REM atonia index derived from automatic scoring showed strong agreement with manually scored data, with minimal bias (≤0.03), narrow limits of agreement (≤0.13), and strong linear correlation (Peason's r ≥ 0.88).ConclusionsFully automated RSWA quantification using single-channel chin EMG is feasible and performs comparable to semi-automatic methods that rely on human sleep stage scoring based on polysomnography. This single-sensor approach can improve RBD screening accessibility, particularly in ambulatory settings, and facilitate long term monitoring of RSWA.

Journal of Parkinson s Disease
NXP (Netherlands) (NL), Philips (Netherlands) (NL), Kempenhaeghe (NL), Eindhoven University of Technology (NL)
Ministerie van Economische Zaken, Landbouw en Innovatie
Decent work and economic growth
Openalex Percentile: Top 8%
Sleep and Wakefulness Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.