Transcatheter Tricuspid Valve Replacement for Residual Tricuspid Regurgitation After TEER

BACKGROUND: Residual or recurrent tricuspid regurgitation (TR) after prior transcatheter tricuspid edge-to-edge (T-TEER) repair occurs in about 12% of patients within 1 year. Since surgical tricuspid valve repair or replacement is of high risk, treatment options remain scarce. Data regarding the feasibility, safety, and treatment strategies using transcatheter valve replacement (TTVR) after T-TEER are sparse. AIMS: Here, we aimed to summarize our early experience in TTVR after failed T-TEER, analyze its feasibility and summarize the results in a distinct algorithm. METHODS: Patients undergoing TTVR (n = 21) at the University Hospital of Duesseldorf were prospectively analyzed and stratified according prior T-TEER procedures with implanted devices. Groups were compared in terms of procedural success, periprocedural complications, and patient outcomes. Individual treatment decisions for patients after T-TEER were analyzed. RESULTS: Five patients had residual/recurrent severe to torrential TR and underwent TTVR after T-TEER, whereas 16 patients were primarily referred for TTVR. Preprocedural wire-based intentional clip excision (WICE) was performed in 60% of these patients. Patients did not differ regarding procedural success (100% in both groups, p = 0.99) and periprocedural complications (0 [TTVR after TEER] vs. 5.6% [primary TTVR], p = 0.99 for the combined endpoint of in-hospital death, stroke, myocardial infarction, re-intervention or surgery, and major bleeding). A pacemaker was required in one patient of each group, p = 0.4). Procedural times were higher among patients with prior T-TEER. Treatment decisions for patients after T-TEER were integrated into a treatment algorithm. CONCLUSION: The valve after clip concept is feasible and the proposed algorithm may support procedural planning.

Authors

Institutions

Publication Details

Journal
Catheterization and Cardiovascular Interventions
Published
2026-08-03
DOI
https://doi.org/10.1002/ccd.70797
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transcatheter Tricuspid Valve Replacement for Residual Tricuspid Regurgitation After TEER

Philipp Mourikis, Maximilian Spieker, Amin Polzin, Patrick Horn et al.
Catheterization and Cardiovascular Interventions
Cardiac Valve Diseases and Treatments
article

Transcatheter Tricuspid Valve Replacement for Residual Tricuspid Regurgitation After TEER

Philipp Mourikis, Maximilian Spieker, Amin Polzin, Patrick Horn, Fabian Voß, Jafer Haschemi, Richard Truse, Hanna Kowalski, Alexander Hoss, Artur Lichtenberg, Malte Kelm, Tobias Zeus, Christian Jung, Fabian Nienhaus, Hug Aubin
article en

Abstract

BACKGROUND: Residual or recurrent tricuspid regurgitation (TR) after prior transcatheter tricuspid edge-to-edge (T-TEER) repair occurs in about 12% of patients within 1 year. Since surgical tricuspid valve repair or replacement is of high risk, treatment options remain scarce. Data regarding the feasibility, safety, and treatment strategies using transcatheter valve replacement (TTVR) after T-TEER are sparse. AIMS: Here, we aimed to summarize our early experience in TTVR after failed T-TEER, analyze its feasibility and summarize the results in a distinct algorithm. METHODS: Patients undergoing TTVR (n = 21) at the University Hospital of Duesseldorf were prospectively analyzed and stratified according prior T-TEER procedures with implanted devices. Groups were compared in terms of procedural success, periprocedural complications, and patient outcomes. Individual treatment decisions for patients after T-TEER were analyzed. RESULTS: Five patients had residual/recurrent severe to torrential TR and underwent TTVR after T-TEER, whereas 16 patients were primarily referred for TTVR. Preprocedural wire-based intentional clip excision (WICE) was performed in 60% of these patients. Patients did not differ regarding procedural success (100% in both groups, p = 0.99) and periprocedural complications (0 [TTVR after TEER] vs. 5.6% [primary TTVR], p = 0.99 for the combined endpoint of in-hospital death, stroke, myocardial infarction, re-intervention or surgery, and major bleeding). A pacemaker was required in one patient of each group, p = 0.4). Procedural times were higher among patients with prior T-TEER. Treatment decisions for patients after T-TEER were integrated into a treatment algorithm. CONCLUSION: The valve after clip concept is feasible and the proposed algorithm may support procedural planning.

Catheterization and Cardiovascular Interventions
Heinrich Heine University Düsseldorf (DE)
Good health and well-being
Openalex Percentile: Top 9%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.