Wear behavior and material performance optimization of articular cartilage under cross-shear motion

BackgroundWith population aging and an increase in sports injuries, articular cartilage wear has become increasingly severe, significantly impairing patients' quality of life. Cross-shear motion is a common loading pattern in daily joint activities, yet its effects on cartilage and counterpart materials remain insufficiently investigated.ObjectiveTo investigate the wear behavior and underlying mechanisms of articular cartilage under cross-shear motion, and to compare the wear resistance of different artificial joint materials, so as to propose material optimization strategies suitable for this motion pattern.MethodsFresh bovine knee femoral cartilage was used to simulate the human cartilage environment under various cross-shear conditions and loading regimes. Stepwise loading, microhardness testing, cartilage compression deformation measurements, and surface wettability tests were performed to systematically analyze the tribological characteristics and wear mechanisms of each material. The evaluated materials included CoCrMo, ultra-high molecular weight polyethylene, and polyether-ether-ketone (PEEK).ResultsCross-shear motion significantly increased wear in all materials. CoCrMo exhibited the largest increase (ΔK = 230.51 ± 25.67%), while PEEK showed the smallest increase in wear rate (138.37%). No significant linear correlation was found between material hardness and cross-shear wear rate (r = -0.32, p > 0.05). In terms of dynamic wettability, PEEK performed best, with a hysteresis angle 38.46% lower than that of natural cartilage, and its energy dissipation parameters were close to those of natural cartilage, indicating the best cartilage compatibility.ConclusionUnder cross-shear conditions, PEEK demonstrates the best overall wear resistance and biomechanical compatibility, suggesting its potential as a promising material for joint repair. The wear mechanisms revealed in this study provide experimental evidence and reference for performance optimization and clinical selection of artificial joint materials.

Authors

Institutions

Publication Details

Journal
Bio-Medical Materials and Engineering
Published
2026-08-03
DOI
https://doi.org/10.1177/09592989261471950
Primary Topic
Osteoarthritis Treatment and Mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wear behavior and material performance optimization of articular cartilage under cross-shear motion

Xiang Li
Bio-Medical Materials and Engineering
Osteoarthritis Treatment and Mechanisms
article

Wear behavior and material performance optimization of articular cartilage under cross-shear motion

Xiang Li
article en

Abstract

BackgroundWith population aging and an increase in sports injuries, articular cartilage wear has become increasingly severe, significantly impairing patients' quality of life. Cross-shear motion is a common loading pattern in daily joint activities, yet its effects on cartilage and counterpart materials remain insufficiently investigated.ObjectiveTo investigate the wear behavior and underlying mechanisms of articular cartilage under cross-shear motion, and to compare the wear resistance of different artificial joint materials, so as to propose material optimization strategies suitable for this motion pattern.MethodsFresh bovine knee femoral cartilage was used to simulate the human cartilage environment under various cross-shear conditions and loading regimes. Stepwise loading, microhardness testing, cartilage compression deformation measurements, and surface wettability tests were performed to systematically analyze the tribological characteristics and wear mechanisms of each material. The evaluated materials included CoCrMo, ultra-high molecular weight polyethylene, and polyether-ether-ketone (PEEK).ResultsCross-shear motion significantly increased wear in all materials. CoCrMo exhibited the largest increase (ΔK = 230.51 ± 25.67%), while PEEK showed the smallest increase in wear rate (138.37%). No significant linear correlation was found between material hardness and cross-shear wear rate (r = -0.32, p > 0.05). In terms of dynamic wettability, PEEK performed best, with a hysteresis angle 38.46% lower than that of natural cartilage, and its energy dissipation parameters were close to those of natural cartilage, indicating the best cartilage compatibility.ConclusionUnder cross-shear conditions, PEEK demonstrates the best overall wear resistance and biomechanical compatibility, suggesting its potential as a promising material for joint repair. The wear mechanisms revealed in this study provide experimental evidence and reference for performance optimization and clinical selection of artificial joint materials.

Bio-Medical Materials and Engineering
Chongqing Technology and Business University (CN)
Openalex Percentile: Top 8%
Osteoarthritis Treatment and Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Wear behavior and material performance optimization of articular cartilage under cross-shear motion — Xiang Li · Bio-Medical Materials and Engineering (2026) | TGRS Research Map | TGRS