Environment-Dependent UV Response of Cyclosporin A in Buffered Aqueous Media: Implications for Reliable Quantitative Analysis in Ophthalmic Drug-Delivery Research

Background: Cyclosporin A (CyA) is widely investigated for ophthalmic drug-delivery systems, including hydrogel contact lenses, where reliable quantification is essential for evaluating drug loading, release, and formulation performance. However, the analytical UV response of CyA may depend on the physicochemical characteristics of the surrounding buffered environment, potentially affecting quantitative measurements. Objectives: This study aimed to determine whether changes in the buffered aqueous environment influence the UV spectral response of CyA and whether such variability may introduce systematic bias into UV-based quantitative analysis. Methods: UV spectra of CyA were recorded in citrate-phosphate buffered media over the pH range 3.28–9.10, including several near-neutral conditions relevant to ophthalmic formulations and artificial lacrimal media. Spectral changes were evaluated using univariate statistical analysis, principal component analysis (PCA), and Gaussian deconvolution. Results: CyA exhibited a progressive hypsochromic shift of the apparent absorption maximum from approximately 234 nm to 210–214 nm, accompanied by pronounced changes in absorbance intensity and the overall absorption profile. Comprehensive statistical analyses demonstrated systematic spectral differences across the investigated buffered media. PCA performed on 42 spectra (31 wavelength variables) explained 84.20% of the total variance within the first two principal components, while Gaussian deconvolution indicated progressive redistribution of overlapping spectral contributions. The observed spectral behavior is consistent with changes in the molecular environment and redistribution of conformational populations; however, the UV–Vis data alone do not provide direct structural evidence for these processes. The resulting wavelength-dependent spectral variability produced substantial apparent analytical bias, demonstrating that fixed-wavelength UV measurements may lead to systematic quantification errors when calibration standards and analytical samples differ in their buffered environment. Conclusions: These findings demonstrate that the analytical UV response of cyclosporin A is environment-dependent and highlight the importance of matrix-matched calibration and validation under the intended analytical conditions when UV spectroscopy is used for quantitative determination of CyA in aqueous drug-delivery systems.

Authors

Institutions

Publication Details

Journal
Pharmaceutics
Published
2026-08-03
DOI
https://doi.org/10.3390/pharmaceutics18080956
Primary Topic
Ocular Surface and Contact Lens
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Environment-Dependent UV Response of Cyclosporin A in Buffered Aqueous Media: Implications for Reliable Quantitative Analysis in Ophthalmic Drug-Delivery Research

I. Rykowska, Rafał Nowak, Iwona Nowak, Ola Michałkiewicz
Pharmaceutics
Ocular Surface and Contact Lens
article

Environment-Dependent UV Response of Cyclosporin A in Buffered Aqueous Media: Implications for Reliable Quantitative Analysis in Ophthalmic Drug-Delivery Research

I. Rykowska, Rafał Nowak, Iwona Nowak, Ola Michałkiewicz
article en

Abstract

Background: Cyclosporin A (CyA) is widely investigated for ophthalmic drug-delivery systems, including hydrogel contact lenses, where reliable quantification is essential for evaluating drug loading, release, and formulation performance. However, the analytical UV response of CyA may depend on the physicochemical characteristics of the surrounding buffered environment, potentially affecting quantitative measurements. Objectives: This study aimed to determine whether changes in the buffered aqueous environment influence the UV spectral response of CyA and whether such variability may introduce systematic bias into UV-based quantitative analysis. Methods: UV spectra of CyA were recorded in citrate-phosphate buffered media over the pH range 3.28–9.10, including several near-neutral conditions relevant to ophthalmic formulations and artificial lacrimal media. Spectral changes were evaluated using univariate statistical analysis, principal component analysis (PCA), and Gaussian deconvolution. Results: CyA exhibited a progressive hypsochromic shift of the apparent absorption maximum from approximately 234 nm to 210–214 nm, accompanied by pronounced changes in absorbance intensity and the overall absorption profile. Comprehensive statistical analyses demonstrated systematic spectral differences across the investigated buffered media. PCA performed on 42 spectra (31 wavelength variables) explained 84.20% of the total variance within the first two principal components, while Gaussian deconvolution indicated progressive redistribution of overlapping spectral contributions. The observed spectral behavior is consistent with changes in the molecular environment and redistribution of conformational populations; however, the UV–Vis data alone do not provide direct structural evidence for these processes. The resulting wavelength-dependent spectral variability produced substantial apparent analytical bias, demonstrating that fixed-wavelength UV measurements may lead to systematic quantification errors when calibration standards and analytical samples differ in their buffered environment. Conclusions: These findings demonstrate that the analytical UV response of cyclosporin A is environment-dependent and highlight the importance of matrix-matched calibration and validation under the intended analytical conditions when UV spectroscopy is used for quantitative determination of CyA in aqueous drug-delivery systems.

PharmaceuticsVol. 18(8)
Adam Mickiewicz University in Poznań (PL)
Openalex Percentile: Top 7%
Ocular Surface and Contact Lens
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.