Dynamic Exergoenvironmental Priority Inversion in Power-to-Ammonia-to-Power Systems: The Static T0 Fallacy in Hot-Arid Climates

Power-to-Ammonia-to-Power (P2A2P) systems in hot-arid MENA climates reject waste heat through Recuperated Organic Rankine Cycles (RORCs) whose condensation temperature tracks ambient conditions across annual swings exceeding 35 K. Standard exergoenvironmental assessments evaluate priorities at a single dead-state temperature, an assumption this study terms the Static T0 Fallacy. A four-way advanced exergy decomposition is combined with an off-design model (Stodola’s ellipse, constant-UA scaling) to sweep the dead-state temperature from 5 ∘C to 40 ∘C. At T0=20 ∘C, 95.8% of total exergy destruction is endogenous, confirming weak inter-component coupling. The condenser carries the largest avoidable environmental impact rate (4.02 mPts/h, 74% of the system total). At T0=37.4 ∘C, the recuperator undergoes a priority inversion from destruction-dominated (fb=14.7%) to fully capital-dominated (fb=100%). Ammonia’s wet-fluid thermodynamic coupling eliminates the recuperator’s duty as the condensation temperature approaches the cold-side outlet constraint. The recuperator’s avoidable environmental impact rate drops by 100% relative to the standard assessment, while the condenser’s rises by 49%. This inversion mechanism is fluid-specific: the ammonia recuperator’s endogenous fraction reaches 99.5% at T0=20 ∘C. The toluene recuperator, swept at its own independently optimised operating point, has an endogenous fraction between 59.08% and 82.31% over the same range. For P2A2P installations where the annual ambient swing exceeds 15 K, exergoenvironmental analysis should be performed at both design-season and summer-peak dead-state temperatures, with the summer-peak result governing capital allocation.

Authors

Institutions

Publication Details

Journal
Clean Technologies
Published
2026-08-03
DOI
https://doi.org/10.3390/cleantechnol8040120
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic Exergoenvironmental Priority Inversion in Power-to-Ammonia-to-Power Systems: The Static T0 Fallacy in Hot-Arid Climates

Ammar Bany Ata, Hussein Kokash, Sameeh Baqain, Mwafak Shakoor et al.
Clean Technologies
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
article

Dynamic Exergoenvironmental Priority Inversion in Power-to-Ammonia-to-Power Systems: The Static T0 Fallacy in Hot-Arid Climates

Ammar Bany Ata, Hussein Kokash, Sameeh Baqain, Mwafak Shakoor, Hamzah Bany-Ata
article en

Abstract

Power-to-Ammonia-to-Power (P2A2P) systems in hot-arid MENA climates reject waste heat through Recuperated Organic Rankine Cycles (RORCs) whose condensation temperature tracks ambient conditions across annual swings exceeding 35 K. Standard exergoenvironmental assessments evaluate priorities at a single dead-state temperature, an assumption this study terms the Static T0 Fallacy. A four-way advanced exergy decomposition is combined with an off-design model (Stodola’s ellipse, constant-UA scaling) to sweep the dead-state temperature from 5 ∘C to 40 ∘C. At T0=20 ∘C, 95.8% of total exergy destruction is endogenous, confirming weak inter-component coupling. The condenser carries the largest avoidable environmental impact rate (4.02 mPts/h, 74% of the system total). At T0=37.4 ∘C, the recuperator undergoes a priority inversion from destruction-dominated (fb=14.7%) to fully capital-dominated (fb=100%). Ammonia’s wet-fluid thermodynamic coupling eliminates the recuperator’s duty as the condensation temperature approaches the cold-side outlet constraint. The recuperator’s avoidable environmental impact rate drops by 100% relative to the standard assessment, while the condenser’s rises by 49%. This inversion mechanism is fluid-specific: the ammonia recuperator’s endogenous fraction reaches 99.5% at T0=20 ∘C. The toluene recuperator, swept at its own independently optimised operating point, has an endogenous fraction between 59.08% and 82.31% over the same range. For P2A2P installations where the annual ambient swing exceeds 15 K, exergoenvironmental analysis should be performed at both design-season and summer-peak dead-state temperatures, with the summer-peak result governing capital allocation.

Clean TechnologiesVol. 8(4)
Jordan University of Science and Technology (JO), American University of Madaba (JO)
Climate action
Openalex Percentile: Top 17%
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.