Physically Constrained Dual-Branch Front-End Optimization for DDH-Oriented Surgical Robot Navigation

Surgical robot navigation in a restricted pelvic workspace requires accurate target localization, directional consistency and robot-feasible execution. This study proposes a physically constrained dual-branch front-end network (PCD-Net) for DDH-oriented navigation using public CT-derived pelvis geometries. PCD-Net maps a 21-dimensional input comprising the target geometry, current joint state, workspace bounds and constraint parameters to a base-frame target position, principal insertion direction and seven-joint correction vector for MoveIt2 and OMPL planning. Training combines supervised pretraining with direction consistency, joint limit, correction magnitude and workspace gap penalties. Evaluation comprised 15 complete simulation trials per method and target sequence-level fivefold cross-validation of 999 samples from five complete sequences. PCD-Net achieved a position error of 0.736±0.202 mm, a direction error of 0.428±0.130°, a planning time of 0.0162±0.0040 s and successful execution in all 15 trials. In cross-validation, the complete constraint setting produced the lowest joint correction MAE (0.755±0.034 rad) and temporal correction variation (3.270±0.589 rad) while maintaining sub-millimeter position and sub-degree direction errors. Removing the joint limit penalty increased the violation rate by 42.35%. These results support PCD-Net as a lightweight, planner-compatible front end that balances geometric accuracy and joint-level feasibility. All evidence is simulation-based; phantom experiments, physical robot validation and evaluation using clinically characterized DDH cases remain necessary before surgical translation.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2026-08-03
DOI
https://doi.org/10.3390/bioengineering13080895
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Physically Constrained Dual-Branch Front-End Optimization for DDH-Oriented Surgical Robot Navigation

Shaoyue Wang, Ziyang Wang, Kang Xie, Chengjun Wang et al.
Bioengineering
Soft Robotics and Applications
article

Physically Constrained Dual-Branch Front-End Optimization for DDH-Oriented Surgical Robot Navigation

Shaoyue Wang, Ziyang Wang, Kang Xie, Chengjun Wang, Jiabao Li, Dongdong Ye, Ming Zhu
article en

Abstract

Surgical robot navigation in a restricted pelvic workspace requires accurate target localization, directional consistency and robot-feasible execution. This study proposes a physically constrained dual-branch front-end network (PCD-Net) for DDH-oriented navigation using public CT-derived pelvis geometries. PCD-Net maps a 21-dimensional input comprising the target geometry, current joint state, workspace bounds and constraint parameters to a base-frame target position, principal insertion direction and seven-joint correction vector for MoveIt2 and OMPL planning. Training combines supervised pretraining with direction consistency, joint limit, correction magnitude and workspace gap penalties. Evaluation comprised 15 complete simulation trials per method and target sequence-level fivefold cross-validation of 999 samples from five complete sequences. PCD-Net achieved a position error of 0.736±0.202 mm, a direction error of 0.428±0.130°, a planning time of 0.0162±0.0040 s and successful execution in all 15 trials. In cross-validation, the complete constraint setting produced the lowest joint correction MAE (0.755±0.034 rad) and temporal correction variation (3.270±0.589 rad) while maintaining sub-millimeter position and sub-degree direction errors. Removing the joint limit penalty increased the violation rate by 42.35%. These results support PCD-Net as a lightweight, planner-compatible front end that balances geometric accuracy and joint-level feasibility. All evidence is simulation-based; phantom experiments, physical robot validation and evaluation using clinically characterized DDH cases remain necessary before surgical translation.

BioengineeringVol. 13(8)
Aviation Industry Corporation of China (China) (CN), Aston University (GB), Precision for Medicine (United States) (US), Anhui Polytechnic University (CN)
Openalex Percentile: Top 18%
Soft Robotics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.