BIS-based model reference adaptive control of anesthesia depth under patient variability and time-varying delays

General anesthesia plays a critical role in modern surgical care, requiring accurate regulation of hypnotic and analgesic drug administration to maintain unconsciousness and analgesia. A major challenge in anesthesia control is the presence of significant inter-patient variability and physiological time-varying delays. Conventional control approaches often rely on manual tuning or patient-specific parameter identification, limiting their applicability in real clinical settings. This study proposes a Model Reference Adaptive Control (MRAC) strategy for automated closed-loop regulation of anesthesia depth using propofol and remifentanil. The proposed framework incorporates a Pharmacokinetic/Pharmacodynamic model and compensates for nonlinear drug-response behavior through an inverse Hill-function approach. A key advantage of the proposed adaptive controller is its independence from patient-specific tuning and prior parameter identification, enabling real-time personalized anesthesia management without model recalibration. Simulation results on a heterogeneous virtual patient population demonstrate settling times of approximately 4–6 min during induction with minimal overshoot (< 5%). The Bispectral Index (BIS) was successfully maintained within the clinically acceptable range of 40–60, with an average value close to 50 and small deviations (± 2). Compared with previously reported anesthesia control strategies, the proposed MRAC approach achieves competitive tracking performance while maintaining stable tracking across heterogeneous virtual simulated patients and time-varying delays. These findings suggest that the proposed strategy provides a promising solution for robust and individualized closed-loop anesthesia management.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-11-13
DOI
https://doi.org/10.1038/s41598-026-78511-4
Primary Topic
Anesthesia and Sedative Agents
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

BIS-based model reference adaptive control of anesthesia depth under patient variability and time-varying delays

Zahra Baharlouei, Marzieh Kamali, Raha Rahimi, Fazaneh Shayegh
1 links
Scientific Reports
Anesthesia and Sedative Agents
article

BIS-based model reference adaptive control of anesthesia depth under patient variability and time-varying delays

Zahra Baharlouei, Marzieh Kamali, Raha Rahimi, Fazaneh Shayegh
article en

Abstract

General anesthesia plays a critical role in modern surgical care, requiring accurate regulation of hypnotic and analgesic drug administration to maintain unconsciousness and analgesia. A major challenge in anesthesia control is the presence of significant inter-patient variability and physiological time-varying delays. Conventional control approaches often rely on manual tuning or patient-specific parameter identification, limiting their applicability in real clinical settings. This study proposes a Model Reference Adaptive Control (MRAC) strategy for automated closed-loop regulation of anesthesia depth using propofol and remifentanil. The proposed framework incorporates a Pharmacokinetic/Pharmacodynamic model and compensates for nonlinear drug-response behavior through an inverse Hill-function approach. A key advantage of the proposed adaptive controller is its independence from patient-specific tuning and prior parameter identification, enabling real-time personalized anesthesia management without model recalibration. Simulation results on a heterogeneous virtual patient population demonstrate settling times of approximately 4–6 min during induction with minimal overshoot (< 5%). The Bispectral Index (BIS) was successfully maintained within the clinically acceptable range of 40–60, with an average value close to 50 and small deviations (± 2). Compared with previously reported anesthesia control strategies, the proposed MRAC approach achieves competitive tracking performance while maintaining stable tracking across heterogeneous virtual simulated patients and time-varying delays. These findings suggest that the proposed strategy provides a promising solution for robust and individualized closed-loop anesthesia management.

Scientific Reports
Isfahan University of Medical Sciences (IR), Isfahan University of Technology (IR)
Isfahan University of Medical Sciences
Good health and well-being
Anesthesia and Sedative Agents
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon