Diagnostic Value of Multiplane Tool in Virtual Lesion Confirmation in Augmented Fluoroscopy-Guided Navigational Bronchoscopy for Peripheral Pulmonary Lesions

BACKGROUND: The demand for minimally invasive diagnostic techniques for peripheral pulmonary lesions (PPL) is rising. Augmented fluoroscopy (AF) provides real-time guidance by overlaying CT-derived virtual targets onto fluoroscopic images, yet its diagnostic value remains poorly defined. METHODS: We retrospectively analyzed 226 PPLs targeting procedures performed with navigational bronchoscopy supplemented by AF and R-EBUS between December 2019 and March 2024. TIVL was assessed across 5 standard planes (posteroanterior, 30 degrees toward, 30 degrees away, 30 degrees clockwise, and 30 degrees counterclockwise). Diagnostic yield was defined according to the ATS/ACCP strict criteria. Multivariable logistic regression identified predictors of diagnostic success. RESULTS: Of the 226 analyzed PPLs, 101 (44.7%) showed no R-EBUS signal. In lesions without an R-EBUS signal, diagnostic yield increased from 0% with ≤1 plane to 42% with ≥4 planes. In multivariable analysis, TIVL in 3 planes was associated with a >5-fold higher likelihood of diagnostic success (OR: 5.57; P<0.05), and in ≥4 planes with an almost 14-fold increase (OR: 13.6; P=0.01). Lesions within 16 mm of the point of entry demonstrated stepwise yield improvements up to 89% with ≥4 confirmed planes, while more distant lesions showed no significant benefit. In the ≥3-TIVL-plane subgroup, BMI showed a negative trend toward lower diagnostic yield (OR: 0.92; P=0.059). CONCLUSION: The number of fluoroscopic planes with confirmed TIVL is a significant determinant of diagnostic yield in AF-guided navigational bronchoscopy, particularly in lesions lacking R-EBUS signals. Multiplane TIVL assessment may enhance diagnostic performance in centers without cone-beam CT or digital tomosynthesis availability.

Authors

Institutions

Publication Details

Journal
Journal of Bronchology & Interventional Pulmonology
Published
2026-08-03
DOI
https://doi.org/10.1097/lbr.0000000000001091
Primary Topic
Lung Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic Value of Multiplane Tool in Virtual Lesion Confirmation in Augmented Fluoroscopy-Guided Navigational Bronchoscopy for Peripheral Pulmonary Lesions

Anika Hüsing, Luca Salhöfer, H Zellerhoff, Jan Büscher et al.
Journal of Bronchology & Interventional Pulmonology
Lung Cancer Diagnosis and Treatment
article

Diagnostic Value of Multiplane Tool in Virtual Lesion Confirmation in Augmented Fluoroscopy-Guided Navigational Bronchoscopy for Peripheral Pulmonary Lesions

Anika Hüsing, Luca Salhöfer, H Zellerhoff, Jan Büscher, Faustina Funke, Sebastian Zensen, Kaid Darwiche, Erik Büscher, Jeffrey Thiboutot, Halil I. Tazeoglu, Marcel Opitz, Johannes Haubold, Lonny Yarmus, Christian Taube, Johannes Wienker, Jane Winantea
article en

Abstract

BACKGROUND: The demand for minimally invasive diagnostic techniques for peripheral pulmonary lesions (PPL) is rising. Augmented fluoroscopy (AF) provides real-time guidance by overlaying CT-derived virtual targets onto fluoroscopic images, yet its diagnostic value remains poorly defined. METHODS: We retrospectively analyzed 226 PPLs targeting procedures performed with navigational bronchoscopy supplemented by AF and R-EBUS between December 2019 and March 2024. TIVL was assessed across 5 standard planes (posteroanterior, 30 degrees toward, 30 degrees away, 30 degrees clockwise, and 30 degrees counterclockwise). Diagnostic yield was defined according to the ATS/ACCP strict criteria. Multivariable logistic regression identified predictors of diagnostic success. RESULTS: Of the 226 analyzed PPLs, 101 (44.7%) showed no R-EBUS signal. In lesions without an R-EBUS signal, diagnostic yield increased from 0% with ≤1 plane to 42% with ≥4 planes. In multivariable analysis, TIVL in 3 planes was associated with a >5-fold higher likelihood of diagnostic success (OR: 5.57; P<0.05), and in ≥4 planes with an almost 14-fold increase (OR: 13.6; P=0.01). Lesions within 16 mm of the point of entry demonstrated stepwise yield improvements up to 89% with ≥4 confirmed planes, while more distant lesions showed no significant benefit. In the ≥3-TIVL-plane subgroup, BMI showed a negative trend toward lower diagnostic yield (OR: 0.92; P=0.059). CONCLUSION: The number of fluoroscopic planes with confirmed TIVL is a significant determinant of diagnostic yield in AF-guided navigational bronchoscopy, particularly in lesions lacking R-EBUS signals. Multiplane TIVL assessment may enhance diagnostic performance in centers without cone-beam CT or digital tomosynthesis availability.

Journal of Bronchology & Interventional PulmonologyVol. 33(4)
Johns Hopkins University (US), TU Dortmund University (DE), Johns Hopkins Medicine (US), Ruhrlandklinik (DE), Lungenklinik Hemer (DE), Pulmonary Associates (US), University of Duisburg-Essen (DE)
Openalex Percentile: Top 10%
Lung Cancer Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.