Study on the Seismic Performance of Prefabricated Walls Under the Synergistic Effect of Different Connection Methods and Low-Carbon Materials

Dry-connected prefabricated composite walls have been increasingly used in steel structures owing to the development of building industrialization and the demand for rapid and efficient construction. However, the respective influences of dry-connection configuration and wall panel material on the seismic response of prefabricated composite walls require further clarification. To address this issue, full-scale quasi-static tests, continuum damage mechanics (CDM) analysis, and finite element simulations were conducted. Six specimens were tested under low-cycle reversed loading. The influence of connection type was evaluated by comparing MRC walls with U-type and Z-type connections, whereas the influence of wall panel material was evaluated by comparing MRC and SFC walls under U-type connections. For the tested MRC walls, the deformation capacity of the connections strongly influenced the failure mode. The U-type rigid connections provided limited deformation buffering, resulting in stress concentration at the wall ends, initial cracking at displacements of 8–10 mm, rapid crack propagation, and semi-brittle failure. In contrast, the Z-type flexible connections released deformation demand through the slip and rotation mechanisms of the slotted holes. The maximum tested displacements of the Z-type specimens were approximately 2.58–2.78 times the ultimate displacements of the corresponding U-type specimens. The Z-type specimens maintained stable load-carrying behavior with limited panel damage throughout the tested displacement range. Furthermore, a restoring-force calculation method was established based on CDM theory, and the predicted peak loads were generally consistent with the experimental results. This study identifies the load-transfer, deformation, and energy-dissipation characteristics of the tested connection–panel configurations and provides comparative evidence for the further development of prefabricated composite wall systems.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-08-03
DOI
https://doi.org/10.3390/buildings16153075
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on the Seismic Performance of Prefabricated Walls Under the Synergistic Effect of Different Connection Methods and Low-Carbon Materials

Y. Li, Feixiang Yu, Zebing Fan, Hongjie Zhu et al.
Buildings
Seismic Performance and Analysis
article

Study on the Seismic Performance of Prefabricated Walls Under the Synergistic Effect of Different Connection Methods and Low-Carbon Materials

Y. Li, Feixiang Yu, Zebing Fan, Hongjie Zhu, Hao Wang
article en

Abstract

Dry-connected prefabricated composite walls have been increasingly used in steel structures owing to the development of building industrialization and the demand for rapid and efficient construction. However, the respective influences of dry-connection configuration and wall panel material on the seismic response of prefabricated composite walls require further clarification. To address this issue, full-scale quasi-static tests, continuum damage mechanics (CDM) analysis, and finite element simulations were conducted. Six specimens were tested under low-cycle reversed loading. The influence of connection type was evaluated by comparing MRC walls with U-type and Z-type connections, whereas the influence of wall panel material was evaluated by comparing MRC and SFC walls under U-type connections. For the tested MRC walls, the deformation capacity of the connections strongly influenced the failure mode. The U-type rigid connections provided limited deformation buffering, resulting in stress concentration at the wall ends, initial cracking at displacements of 8–10 mm, rapid crack propagation, and semi-brittle failure. In contrast, the Z-type flexible connections released deformation demand through the slip and rotation mechanisms of the slotted holes. The maximum tested displacements of the Z-type specimens were approximately 2.58–2.78 times the ultimate displacements of the corresponding U-type specimens. The Z-type specimens maintained stable load-carrying behavior with limited panel damage throughout the tested displacement range. Furthermore, a restoring-force calculation method was established based on CDM theory, and the predicted peak loads were generally consistent with the experimental results. This study identifies the load-transfer, deformation, and energy-dissipation characteristics of the tested connection–panel configurations and provides comparative evidence for the further development of prefabricated composite wall systems.

BuildingsVol. 16(15)
Southwest University of Science and Technology (CN)
National Natural Science Foundation of China, Southwest University of Science and Technology, Southwest University, University of Science and Technology of China, Natural Science Foundation of Sichuan Province, Sichuan Province Science and Technology Support Program
Sustainable cities and communities
Openalex Percentile: Top 15%
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.