Finite element analysis of a novel repair device for lumbar spondylolysis

Abstract Background This study aimed to compare the biomechanical differences between a novel repair device for lumbar spondylolysis and a nail–hook internal fixation system through three-dimensional finite element analysis. Methods Three-dimensional images of L4–S1 were constructed based on computed tomography images of a young male patient. Four finite element models were developed: Model A: intact model; Model B: bilateral spondylolysis of the L5 model; Model C: spondylolysis fixed by the nail–hook internal fixation system model; and Model D: spondylolysis fixed by the novel repair device model. A uniformly distributed 600-N vertical downward concentrated force and 10 Nm of torque were applied to the upper surface of the L4 to simulate six physiological activities of the lumbar spine. The fixation effects were evaluated by comparing the range of motion, maximum stress of the intervertebral disks, maximum displacement of the spondylolysis, and stress distribution of the internal fixation. Results The range of motions of the two internal fixation models were similar in each segment and direction. In terms of the maximum displacement of the spondylolysis, that of the fracture surface in the novel repair device model was significantly reduced compared with the nail–hook internal fixation model in each range of motion. The maximum stress of the intervertebral disks in the two models had their respective advantages in different activity directions, but the difference in stress values was not significant. The stress levels of both internal fixation devices were concentrated on the connecting rod and the junction of the pedicle screw and the connecting rod. Due to the shorter connecting rod of the nail–hook internal fixation system, the stress on the connecting rod was more concentrated, while the stress distribution on the connecting rod of the novel device was more dispersed. Conclusion The new type of lumbar pars interarticularis repair device is highly reliable in fixation, and the bone grafting area of the pars interarticularis is well exposed, providing favorable conditions for bone grafting and subsequent bone formation. It is a highly promising internal fixation device that offers a new option for pars interarticularis repair.

Authors

Institutions

Publication Details

Journal
BMC Musculoskeletal Disorders
Published
2026-08-03
DOI
https://doi.org/10.1186/s12891-026-10238-9
Primary Topic
Spine and Intervertebral Disc Pathology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Finite element analysis of a novel repair device for lumbar spondylolysis

Youpeng Hu, Bin Xie, Hongda Xu, Li Liu et al.
BMC Musculoskeletal Disorders
Spine and Intervertebral Disc Pathology
article

Finite element analysis of a novel repair device for lumbar spondylolysis

Youpeng Hu, Bin Xie, Hongda Xu, Li Liu, Mingfan Li, Haitao Deng, Peidong Qing, Shengxin Zhao
article en

Abstract

Abstract Background This study aimed to compare the biomechanical differences between a novel repair device for lumbar spondylolysis and a nail–hook internal fixation system through three-dimensional finite element analysis. Methods Three-dimensional images of L4–S1 were constructed based on computed tomography images of a young male patient. Four finite element models were developed: Model A: intact model; Model B: bilateral spondylolysis of the L5 model; Model C: spondylolysis fixed by the nail–hook internal fixation system model; and Model D: spondylolysis fixed by the novel repair device model. A uniformly distributed 600-N vertical downward concentrated force and 10 Nm of torque were applied to the upper surface of the L4 to simulate six physiological activities of the lumbar spine. The fixation effects were evaluated by comparing the range of motion, maximum stress of the intervertebral disks, maximum displacement of the spondylolysis, and stress distribution of the internal fixation. Results The range of motions of the two internal fixation models were similar in each segment and direction. In terms of the maximum displacement of the spondylolysis, that of the fracture surface in the novel repair device model was significantly reduced compared with the nail–hook internal fixation model in each range of motion. The maximum stress of the intervertebral disks in the two models had their respective advantages in different activity directions, but the difference in stress values was not significant. The stress levels of both internal fixation devices were concentrated on the connecting rod and the junction of the pedicle screw and the connecting rod. Due to the shorter connecting rod of the nail–hook internal fixation system, the stress on the connecting rod was more concentrated, while the stress distribution on the connecting rod of the novel device was more dispersed. Conclusion The new type of lumbar pars interarticularis repair device is highly reliable in fixation, and the bone grafting area of the pars interarticularis is well exposed, providing favorable conditions for bone grafting and subsequent bone formation. It is a highly promising internal fixation device that offers a new option for pars interarticularis repair.

BMC Musculoskeletal Disorders
Sichuan Mianyang 404 Hospital (CN), Sichuan Academy of Traditional Chinese Medicine (CN)
Openalex Percentile: Top 10%
Spine and Intervertebral Disc Pathology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.