TAVI-TEC: an AI-based tool for procedural planning of transcatheter aortic valve implantation

Computed tomography angiography (CTA) is crucial for preprocedural TAVI planning, providing the anatomical information required for prosthesis sizing and vascular access assessment. As the volume of TAVI procedure increases, improving efficiency and standardizing annotations is becoming essential in clinical practice. This study presents TAVI-TEC, a fully automated artificial intelligence-based framework integrated into a web based DICOM viewer for routine preoperative TAVI planning. Pre-procedural CTA scans from patients undergoing TAVI with SAPIEN 3 Ultra (S3U) prostheses were processed using a fully automated pipeline. Deep learning-based segmentation of cardiovascular structures, calcification detection, centerline extraction, landmark identification, and annular plane definition was implemented to quantify key annular and aortic root measurements and color-coded maps of lumen reduction and vessel diameter for vascular access. A multilayer perceptron classifier was trained to predict prosthesis size prior to the TAVI procedure. Results revealed that TAVI-TEC enabled pre-procedural measurements in approximately 2-6 min. Strong agreement with clinician-derived measurements was observed for annular area (coefficient of concordance, CCC = 0.934; interclass correlation coefficient, ICC = 0.935; R^2 = 0.881) and perimeter (CCC = 0.909; ICC = 0.909; R^2 = 0.854). The valve-size prediction model achieved 82% overall accuracy, with most misclassifications occurring between adjacent prosthesis sizes. Though further multicenter validation and extension to additional measurements and valve platforms are required, the TAVI-TEC methodology may reduce operator variability in pre-TAVI measurements and streamline the preoperative workflows of the Heart Team for decision-making.

Authors

Publication Details

Journal
Cardiovascular Intervention and Therapeutics
Published
2026-09-24
DOI
https://doi.org/10.1007/s12928-026-01356-1
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

TAVI-TEC: an AI-based tool for procedural planning of transcatheter aortic valve implantation

Simone Manini, Diego Bellavia, Daniele Ciriello, Stefano Cannata et al.
Cardiovascular Intervention and Therapeutics
Cardiac Valve Diseases and Treatments
article

TAVI-TEC: an AI-based tool for procedural planning of transcatheter aortic valve implantation

Simone Manini, Diego Bellavia, Daniele Ciriello, Stefano Cannata, Salvatore Pasta, Caterina Gandolfo, Alessandra Zerillo
article en

Abstract

Computed tomography angiography (CTA) is crucial for preprocedural TAVI planning, providing the anatomical information required for prosthesis sizing and vascular access assessment. As the volume of TAVI procedure increases, improving efficiency and standardizing annotations is becoming essential in clinical practice. This study presents TAVI-TEC, a fully automated artificial intelligence-based framework integrated into a web based DICOM viewer for routine preoperative TAVI planning. Pre-procedural CTA scans from patients undergoing TAVI with SAPIEN 3 Ultra (S3U) prostheses were processed using a fully automated pipeline. Deep learning-based segmentation of cardiovascular structures, calcification detection, centerline extraction, landmark identification, and annular plane definition was implemented to quantify key annular and aortic root measurements and color-coded maps of lumen reduction and vessel diameter for vascular access. A multilayer perceptron classifier was trained to predict prosthesis size prior to the TAVI procedure. Results revealed that TAVI-TEC enabled pre-procedural measurements in approximately 2-6 min. Strong agreement with clinician-derived measurements was observed for annular area (coefficient of concordance, CCC = 0.934; interclass correlation coefficient, ICC = 0.935; R^2 = 0.881) and perimeter (CCC = 0.909; ICC = 0.909; R^2 = 0.854). The valve-size prediction model achieved 82% overall accuracy, with most misclassifications occurring between adjacent prosthesis sizes. Though further multicenter validation and extension to additional measurements and valve platforms are required, the TAVI-TEC methodology may reduce operator variability in pre-TAVI measurements and streamline the preoperative workflows of the Heart Team for decision-making.

Cardiovascular Intervention and Therapeutics
Peace, Justice and strong institutions
Openalex Percentile: Top 28%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.