Influence of Baseline Intraoperative Neuromonitoring (IONM) Data Quality on Neuromonitoring Performance and Surgical Actions

Study Design. Retrospective Cohort Study Objective. To examine the impact of abnormal baseline intraoperative neuromonitoring (IONM) data quality on neuromonitoring alerts, surgical decision-making, and the immediate and final neurologic outcomes. Summary of Background Data. The use of IONM is considered the standard of care for pediatric spine deformity surgery due to its ability to identify potential spinal cord dysfunction and facilitate remediating corrective action. However, there is little information regarding the influence of baseline data quality on IONM alerts and subsequent surgical choices and neurologic outcomes. Methods. An institutional neuromonitoring data base was reviewed (1992–2024) to identify all consecutive patients (0–18 y) who underwent pediatric spine deformity surgery with at least one IONM alert. Results. Among 5,317 consecutive cases, 223 (4.2%) had at least 1 IONM alert, and 292 (5.5%) had abnormal baseline data quality. Alerts occurred more frequently in patients with abnormal baselines (14.7% vs. 3.6%, P <0.001). Baseline abnormalities included SSEP only in 46.5%, motor only in 44.2%, and both in 9.3% of cases. The abnormal baseline modality and alert modality matched in 72.1% of cases. Abnormal baselines were associated with abnormal preoperative neurologic status (36.6% vs. 19.4%, P =0.018) but not diagnosis. Alerts occurred earlier in surgery in cases with abnormal baselines ( P <0.001) and failure of data return was more common (44.2% vs. 26.7%, P =0.024). Normal compared with abnormal baseline data quality was not associated with postoperative neurologic deficits postoperatively (14.4% vs. 18.6%, P =0.495) or at final exam (3.9% vs. 2.5%, P =1.00), respectively. Conclusion. Abnormal IONM baseline data quality is associated with increased alert frequency, earlier alert timing, and altered intraoperative management, but not with more postoperative neurologic outcomes. These findings support the continued use of IONM in cases with poor baseline data quality when interpreted in clinical context and managed with established protocols.

Authors

Institutions

Publication Details

Journal
Spine
Published
2026-07-30
DOI
https://doi.org/10.1097/brs.0000000000005814
Primary Topic
Intraoperative Neuromonitoring and Anesthetic Effects
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Baseline Intraoperative Neuromonitoring (IONM) Data Quality on Neuromonitoring Performance and Surgical Actions

Leah Rakers, Scott J. Luhmann, Christopher K. Bozorgmehr
Spine
Intraoperative Neuromonitoring and Anesthetic Effects
article

Influence of Baseline Intraoperative Neuromonitoring (IONM) Data Quality on Neuromonitoring Performance and Surgical Actions

Leah Rakers, Scott J. Luhmann, Christopher K. Bozorgmehr
article en

Abstract

Study Design. Retrospective Cohort Study Objective. To examine the impact of abnormal baseline intraoperative neuromonitoring (IONM) data quality on neuromonitoring alerts, surgical decision-making, and the immediate and final neurologic outcomes. Summary of Background Data. The use of IONM is considered the standard of care for pediatric spine deformity surgery due to its ability to identify potential spinal cord dysfunction and facilitate remediating corrective action. However, there is little information regarding the influence of baseline data quality on IONM alerts and subsequent surgical choices and neurologic outcomes. Methods. An institutional neuromonitoring data base was reviewed (1992–2024) to identify all consecutive patients (0–18 y) who underwent pediatric spine deformity surgery with at least one IONM alert. Results. Among 5,317 consecutive cases, 223 (4.2%) had at least 1 IONM alert, and 292 (5.5%) had abnormal baseline data quality. Alerts occurred more frequently in patients with abnormal baselines (14.7% vs. 3.6%, P <0.001). Baseline abnormalities included SSEP only in 46.5%, motor only in 44.2%, and both in 9.3% of cases. The abnormal baseline modality and alert modality matched in 72.1% of cases. Abnormal baselines were associated with abnormal preoperative neurologic status (36.6% vs. 19.4%, P =0.018) but not diagnosis. Alerts occurred earlier in surgery in cases with abnormal baselines ( P <0.001) and failure of data return was more common (44.2% vs. 26.7%, P =0.024). Normal compared with abnormal baseline data quality was not associated with postoperative neurologic deficits postoperatively (14.4% vs. 18.6%, P =0.495) or at final exam (3.9% vs. 2.5%, P =1.00), respectively. Conclusion. Abnormal IONM baseline data quality is associated with increased alert frequency, earlier alert timing, and altered intraoperative management, but not with more postoperative neurologic outcomes. These findings support the continued use of IONM in cases with poor baseline data quality when interpreted in clinical context and managed with established protocols.

Spine
Barnes-Jewish Hospital (US), Washington University in St. Louis (US), Jewish Hospital (US)
Peace, Justice and strong institutions
Openalex Percentile: Top 7%
Intraoperative Neuromonitoring and Anesthetic Effects
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.