Monte carlo assessment of advanced shielding materials for space‐efficient radiotherapy vault design

BACKGROUND: per linac, which can constrain treatment capacity within fixed departmental space. Recent advances in high-density composite shielding materials offer the potential to achieve the same dose-based design goals with reduced barrier thickness. PURPOSE: In this study, we investigate advanced shielding materials, including specialty concretes and high-density polymer composites, as potential alternatives to conventional concrete barriers, aiming to demonstrate that modern materials could safely enable more compact vault designs while maintaining regulatory compliance. METHODS: TOPAS Monte Carlo simulations evaluated a 6 MV and an 18 MV linear accelerator (LINAC) vault comparing conventional concrete against five candidate shielding materials. We modeled a typical 4-vault radiotherapy department to demonstrate potential capacity increase. Simulations calculated linear attenuation coefficients (μ), tenth-value layers (TVLs), and dose distributions at regulatory measurement points. Spatial analyses projected the clinical impact of implementing optimized shielding. RESULTS: While concrete required 165.8 m2 floor area per vault, candidate materials achieved 17%-32% reductions for 6 MV beams and 22%-34% reductions for 18 MV beams. Specifically, Steel-magnetite and Datolite-Galena concretes showed great space-saving potentials with footprint reductions of 28% and 31% for 18 MV beams, respectively, while maintaining refined doses at 2.40 × 10-2 and 2.42 × 10-2 mSv/week, well below the 0.1 mSv/week NCRP limit. CONCLUSION: This study demonstrates that high-density composite shielding may reduce vault footprint while maintaining dose levels below established shielding design limits. These findings suggest that systematic evaluation of alternative shielding materials may provide useful insights for space-efficient radiotherapy vault design while remaining within established dose-based shielding frameworks.

Authors

Institutions

Publication Details

Journal
Journal of Applied Clinical Medical Physics
Published
2026-07-30
DOI
https://doi.org/10.1002/acm2.70728
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Monte carlo assessment of advanced shielding materials for space‐efficient radiotherapy vault design

Beechui Koo, Jungwook Shin, James J. Sohn, Morgan Glennie et al.
Journal of Applied Clinical Medical Physics
Advanced Radiotherapy Techniques
article

Monte carlo assessment of advanced shielding materials for space‐efficient radiotherapy vault design

Beechui Koo, Jungwook Shin, James J. Sohn, Morgan Glennie, Karl Farrey, Richard Xu, Siyong Kim
article en

Abstract

BACKGROUND: per linac, which can constrain treatment capacity within fixed departmental space. Recent advances in high-density composite shielding materials offer the potential to achieve the same dose-based design goals with reduced barrier thickness. PURPOSE: In this study, we investigate advanced shielding materials, including specialty concretes and high-density polymer composites, as potential alternatives to conventional concrete barriers, aiming to demonstrate that modern materials could safely enable more compact vault designs while maintaining regulatory compliance. METHODS: TOPAS Monte Carlo simulations evaluated a 6 MV and an 18 MV linear accelerator (LINAC) vault comparing conventional concrete against five candidate shielding materials. We modeled a typical 4-vault radiotherapy department to demonstrate potential capacity increase. Simulations calculated linear attenuation coefficients (μ), tenth-value layers (TVLs), and dose distributions at regulatory measurement points. Spatial analyses projected the clinical impact of implementing optimized shielding. RESULTS: While concrete required 165.8 m2 floor area per vault, candidate materials achieved 17%-32% reductions for 6 MV beams and 22%-34% reductions for 18 MV beams. Specifically, Steel-magnetite and Datolite-Galena concretes showed great space-saving potentials with footprint reductions of 28% and 31% for 18 MV beams, respectively, while maintaining refined doses at 2.40 × 10-2 and 2.42 × 10-2 mSv/week, well below the 0.1 mSv/week NCRP limit. CONCLUSION: This study demonstrates that high-density composite shielding may reduce vault footprint while maintaining dose levels below established shielding design limits. These findings suggest that systematic evaluation of alternative shielding materials may provide useful insights for space-efficient radiotherapy vault design while remaining within established dose-based shielding frameworks.

Journal of Applied Clinical Medical PhysicsVol. 27(8)
National Institutes of Health (US), University of Wisconsin System (US), University of Wisconsin–Madison (US), Virginia Commonwealth University (US), University of Chicago (US), National Cancer Institute (US)
Openalex Percentile: Top 9%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.