Development and validation of the Measuring Needle Fear (MNF) screening tool for identification of needle fear in pre-dialysis and dialysis patients

Background: Needle fear is an under-recognised burden among haemodialysis recipients which can influence treatment choice and therapy engagement. Objective: This study aimed to develop and validate a tool to identify needle fear in pre-dialysis or dialysis cohorts. Methods: The Measuring Needle Fear (MNF) tool was developed using deductive and inductive methods, with items grouped into four domains to ensure comprehensive symptom coverage. Content validity was assessed using the Content Validity Index (CVI), and reliability using Gwet’s AC1 coefficient and Cronbach’s alpha. Exploratory factor analysis (EFA) was performed using Principal Axis Factoring with oblimin rotation, supported by the Kaiser–Meyer–Olkin statistic and Bartlett’s test. Discriminative ability and the optimal cut-off point were evaluated using ROC analysis. Results: A total of 120 participants completed the questionnaire. Test–retest reliability was excellent for most MNF items (30 items; AC1 = 0.81–1.00) and good for the remainder (nine items; AC1 = 0.61–0.80). EFA identified three factors – Fear, Avoidance and Embarrassment – with excellent sampling adequacy (KMO = 0.908) and a significant Bartlett’s test ( p < 0.001). Internal consistency was high (Cronbach’s alpha = 0.895). ROC analysis demonstrated excellent discrimination (AUC = 0.959), with a score ⩾5 identifying 31% of patients as likely to experience needle fear. Conclusion: The Measuring Needle Fear tool is a validated, reliable method for identifying needle fear in pre-dialysis and dialysis patients, supporting early detection and enabling timely, targeted support.

Authors

Institutions

Publication Details

Journal
The Journal of Vascular Access
Published
2026-07-30
DOI
https://doi.org/10.1177/11297298261470920
Primary Topic
Dialysis and Renal Disease Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and validation of the Measuring Needle Fear (MNF) screening tool for identification of needle fear in pre-dialysis and dialysis patients

Gorjana Radisic, Anna Chur‐Hansen, Richard K. Le Leu, Shilpanjali Jesudason et al.
The Journal of Vascular Access
Dialysis and Renal Disease Management
article

Development and validation of the Measuring Needle Fear (MNF) screening tool for identification of needle fear in pre-dialysis and dialysis patients

Gorjana Radisic, Anna Chur‐Hansen, Richard K. Le Leu, Shilpanjali Jesudason, Kathryn Collins, Fiona Donnelly, Kathy Hill, Adrian Esterman, Anne LJ Burke, Stephen McDonald
article en

Abstract

Background: Needle fear is an under-recognised burden among haemodialysis recipients which can influence treatment choice and therapy engagement. Objective: This study aimed to develop and validate a tool to identify needle fear in pre-dialysis or dialysis cohorts. Methods: The Measuring Needle Fear (MNF) tool was developed using deductive and inductive methods, with items grouped into four domains to ensure comprehensive symptom coverage. Content validity was assessed using the Content Validity Index (CVI), and reliability using Gwet’s AC1 coefficient and Cronbach’s alpha. Exploratory factor analysis (EFA) was performed using Principal Axis Factoring with oblimin rotation, supported by the Kaiser–Meyer–Olkin statistic and Bartlett’s test. Discriminative ability and the optimal cut-off point were evaluated using ROC analysis. Results: A total of 120 participants completed the questionnaire. Test–retest reliability was excellent for most MNF items (30 items; AC1 = 0.81–1.00) and good for the remainder (nine items; AC1 = 0.61–0.80). EFA identified three factors – Fear, Avoidance and Embarrassment – with excellent sampling adequacy (KMO = 0.908) and a significant Bartlett’s test ( p < 0.001). Internal consistency was high (Cronbach’s alpha = 0.895). ROC analysis demonstrated excellent discrimination (AUC = 0.959), with a score ⩾5 identifying 31% of patients as likely to experience needle fear. Conclusion: The Measuring Needle Fear tool is a validated, reliable method for identifying needle fear in pre-dialysis and dialysis patients, supporting early detection and enabling timely, targeted support.

The Journal of Vascular Access
Royal Adelaide Hospital (AU), UCL Australia (AU), Australia and New Zealand Dialysis and Transplant Registry (AU), SA Health (AU), The University of Adelaide (AU)
Reduced inequalities
Openalex Percentile: Top 9%
Dialysis and Renal Disease Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.