An LC-linked Noradrenergic Arousal Indexing via a Delay-Differential Non-Invasive Pupillometry Framework.

This paper argues that the re-dilation trajectory of the Pupillary Light Reflex, which standard pupillometry discards, encodes the loop gain G of a nonlinear delayed negative-feedback system whose operating point is set by tonic Locus Coeruleus output. The central theoretical contribution is an exact analytical solution for the recovery time constant τreturn(G) derived via the Lambert W function, which eliminates the classical zero-delay approximation and correctly locates the Hopf bifurcation at Gc. Full nonlinear simulations of the Longtin-Milton model validate the calibration curve, and a spectral cross-validation independently confirms the bifurcation geometry. From this framework a three-variable instrument architecture which combines resting diameter, recovery dynamics, and a dual-wavelength chromatic post-illumination response,is derived. The work is theoretical and computational throughout; the instrument specification is a principled design consequence of the validated framework, not a clinical prototype, and several falsifiable predictions define the bridge to empirical work.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-07-30
DOI
https://doi.org/10.5281/zenodo.21710938
Primary Topic
Heart Rate Variability and Autonomic Control
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

An LC-linked Noradrenergic Arousal Indexing via a Delay-Differential Non-Invasive Pupillometry Framework.

Ismail Sour
Zenodo (CERN European Organization for Nuclear Research)
Heart Rate Variability and Autonomic Control
preprint

An LC-linked Noradrenergic Arousal Indexing via a Delay-Differential Non-Invasive Pupillometry Framework.

Ismail Sour
preprint en

Abstract

This paper argues that the re-dilation trajectory of the Pupillary Light Reflex, which standard pupillometry discards, encodes the loop gain G of a nonlinear delayed negative-feedback system whose operating point is set by tonic Locus Coeruleus output. The central theoretical contribution is an exact analytical solution for the recovery time constant τreturn(G) derived via the Lambert W function, which eliminates the classical zero-delay approximation and correctly locates the Hopf bifurcation at Gc. Full nonlinear simulations of the Longtin-Milton model validate the calibration curve, and a spectral cross-validation independently confirms the bifurcation geometry. From this framework a three-variable instrument architecture which combines resting diameter, recovery dynamics, and a dual-wavelength chromatic post-illumination response,is derived. The work is theoretical and computational throughout; the instrument specification is a principled design consequence of the validated framework, not a clinical prototype, and several falsifiable predictions define the bridge to empirical work.

Zenodo (CERN European Organization for Nuclear Research)
Université de Limoges (FR)
Heart Rate Variability and Autonomic Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.