A Tale of Two Scopes: Comparative Evaluation of Tuoren® and King Vision® Videolaryngoscopes in Patients Undergoing General Anesthesia

Background: Laryngoscopy remains a cornerstone of airway management in anesthesiology. With advancements in technology, videolaryngoscopes have improved visualization and intubation success rates. Among these, the Tuoren® videolaryngoscope (Tuoren Medical Group, Henan, China) and the King Vision® videolaryngoscope (Ambu A/S, Ballerup, Denmark) have been widely used, although direct clinical comparisons between the two devices remain limited. This research sought to assess and compare ease of intubation, glottic visualization, time efficiency, and success rates between the Tuoren® and King Vision® videolaryngoscopes. Methods: A prospective, randomized, single-blind study was conducted on 98 adult patients with American Society of Anesthesiologists (ASA) physical status I-III undergoing elective surgeries requiring general anesthesia. The participants were allocated into two groups of 49 each: Group I was intubated using the Tuoren® device and Group II using the King Vision® device, after standard induction and neuromuscular blockade. The recorded parameters were intubation time, number of attempts, ease of intubation score, glottic visualization (modified Cormack-Lehane and Percentage of Glottic Opening (POGO) scores), and hemodynamic responses. Statistical analysis was performed using the IBM SPSS Statistics software for Windows, version 21.0 (IBM Corp., Armonk, NY, USA). Results: Patient demographics and baseline airway assessments were comparable between the groups. The mean intubation time was significantly shorter with the Tuoren® videolaryngoscope compared to the King Vision® videolaryngoscope (64.6 ± 28.8 s vs. 79.6 ± 13.2 s, p < 0.001). The Tuoren® group demonstrated a higher median ease of intubation score (3 (IQR 3-4) vs. 3 (IQR 3-3), p = 0.0011). Although King Vision® provided superior glottic views (p = 0.002), this did not translate to easier or faster intubation. Hemodynamic parameters and complication rates were similar between the two groups. Conclusion: Both Tuoren® and King Vision® videolaryngoscopes are effective for tracheal intubation under general anesthesia. While the King Vision® videolaryngoscope offers a marginally better glottic view, the Tuoren® videolaryngoscope provides faster and easier intubation, suggesting its potential as a reliable and cost-effective alternative in clinical practice. Further large-scale studies are warranted to confirm these findings across varied clinical scenarios.

Authors

Publication Details

Journal
Cureus
Published
2026-07-30
DOI
https://doi.org/10.7759/cureus.113671
Primary Topic
Airway Management and Intubation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Tale of Two Scopes: Comparative Evaluation of Tuoren® and King Vision® Videolaryngoscopes in Patients Undergoing General Anesthesia

Deb Sanjay Nag, Amlan Swain, Koshy Varghese, Seelora Sahu et al.
Cureus
Airway Management and Intubation Techniques
article

A Tale of Two Scopes: Comparative Evaluation of Tuoren® and King Vision® Videolaryngoscopes in Patients Undergoing General Anesthesia

Deb Sanjay Nag, Amlan Swain, Koshy Varghese, Seelora Sahu, . Vatsala, Abhishek Karthik
article en

Abstract

Background: Laryngoscopy remains a cornerstone of airway management in anesthesiology. With advancements in technology, videolaryngoscopes have improved visualization and intubation success rates. Among these, the Tuoren® videolaryngoscope (Tuoren Medical Group, Henan, China) and the King Vision® videolaryngoscope (Ambu A/S, Ballerup, Denmark) have been widely used, although direct clinical comparisons between the two devices remain limited. This research sought to assess and compare ease of intubation, glottic visualization, time efficiency, and success rates between the Tuoren® and King Vision® videolaryngoscopes. Methods: A prospective, randomized, single-blind study was conducted on 98 adult patients with American Society of Anesthesiologists (ASA) physical status I-III undergoing elective surgeries requiring general anesthesia. The participants were allocated into two groups of 49 each: Group I was intubated using the Tuoren® device and Group II using the King Vision® device, after standard induction and neuromuscular blockade. The recorded parameters were intubation time, number of attempts, ease of intubation score, glottic visualization (modified Cormack-Lehane and Percentage of Glottic Opening (POGO) scores), and hemodynamic responses. Statistical analysis was performed using the IBM SPSS Statistics software for Windows, version 21.0 (IBM Corp., Armonk, NY, USA). Results: Patient demographics and baseline airway assessments were comparable between the groups. The mean intubation time was significantly shorter with the Tuoren® videolaryngoscope compared to the King Vision® videolaryngoscope (64.6 ± 28.8 s vs. 79.6 ± 13.2 s, p < 0.001). The Tuoren® group demonstrated a higher median ease of intubation score (3 (IQR 3-4) vs. 3 (IQR 3-3), p = 0.0011). Although King Vision® provided superior glottic views (p = 0.002), this did not translate to easier or faster intubation. Hemodynamic parameters and complication rates were similar between the two groups. Conclusion: Both Tuoren® and King Vision® videolaryngoscopes are effective for tracheal intubation under general anesthesia. While the King Vision® videolaryngoscope offers a marginally better glottic view, the Tuoren® videolaryngoscope provides faster and easier intubation, suggesting its potential as a reliable and cost-effective alternative in clinical practice. Further large-scale studies are warranted to confirm these findings across varied clinical scenarios.

Cureus
Zero hunger
Openalex Percentile: Top 7%
Airway Management and Intubation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.