CORSICA: Reproducible suppression of cochlear implant artifacts in EEG evoked by continuous speech

OBJECTIVE: Electroencephalography (EEG) is a key tool for studying auditory processing in cochlear implant (CI) users. In particular, EEG recordings obtained dur- ing continuous speech are becoming increasingly important for assessing speech and language processing in CI users, and may be utilized for neurofeedback. However, CIs also induce strong stimulation artifacts that are time-locked to the stimulus and mask the neural responses that have smaller magnitudes. Existing artifact reduction methods are typically based on event-related potentials (ERPs) or require manual com- ponent selection, making them unsuitable for naturalistic listening conditions or large datasets. APPROACH: We develop CORSICA (CORrelation-baSed ICA artifact re- jection), a reproducible, parameter-efficient method for CI artifact reduction in EEG responses to continuous speech. CORSICA operates on independent components (ICs) obtained through Infomax ICA and requires no manual component labelling, with per- formance governed by a single tunable threshold. It exploits the observation that CI artifacts temporally follow the audio signal without delay, whereas neural responses have an inherent lag due to auditory pathway latencies. For each IC, CORSICA com- putes the cross-correlation with the speech stimulus. Artifacts are identified by a high signal-to-noise ratio (SNR) of the correlation peak near zero lag, and the component is rejected if this SNR exceeds a threshold. To benchmark CORSICA, we evaluate two alternatives: a TRF-based SNR method, in which temporal response functions are fitted to each IC and artifact-driven peaks near zero lag are used for rejection, and a variant replacing ICA with second-order blind identification (SOBI) as the source separation step. MAIN RESULTS: CORSICA effectively suppressed CI artifacts while preserving neural activity, enabling recovery of physiologically plausible TRFs with only 2% of ICs rejected. Both benchmark methods confirmed the validity of the SNR- based rejection framework, but CORSICA outperformed the TRF-based alternative in artifact suppression quality. Replacing ICA with SOBI as the source separation step required more ICs to be rejected, further supporting ICA as the preferred backbone for CORSICA. SIGNIFICANCE: CORSICA provides a fully objective, label-free approach to identifying CI artifacts in speech-evoked EEG data, with no manual intervention required. By centering artifact rejection on a single interpretable threshold, it offers a reproducible preprocessing standard for future EEG studies on speech processing in CI users. CONCLUSION: Our findings demonstrate that objective CI artifact suppres- sion in speech-evoked EEG data is feasible on the basis of the IC's temporal response patterns.

Authors

Institutions

Publication Details

Journal
Journal of Neural Engineering
Published
2026-09-07
DOI
https://doi.org/10.1088/1741-2552/aea36e
Primary Topic
Hearing Loss and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CORSICA: Reproducible suppression of cochlear implant artifacts in EEG evoked by continuous speech

Niki Vavatzanidis, Tobias Reichenbach, C. Jehn, Clara Stiller
Journal of Neural Engineering
Hearing Loss and Rehabilitation
article

CORSICA: Reproducible suppression of cochlear implant artifacts in EEG evoked by continuous speech

Niki Vavatzanidis, Tobias Reichenbach, C. Jehn, Clara Stiller
article en

Abstract

OBJECTIVE: Electroencephalography (EEG) is a key tool for studying auditory processing in cochlear implant (CI) users. In particular, EEG recordings obtained dur- ing continuous speech are becoming increasingly important for assessing speech and language processing in CI users, and may be utilized for neurofeedback. However, CIs also induce strong stimulation artifacts that are time-locked to the stimulus and mask the neural responses that have smaller magnitudes. Existing artifact reduction methods are typically based on event-related potentials (ERPs) or require manual com- ponent selection, making them unsuitable for naturalistic listening conditions or large datasets. APPROACH: We develop CORSICA (CORrelation-baSed ICA artifact re- jection), a reproducible, parameter-efficient method for CI artifact reduction in EEG responses to continuous speech. CORSICA operates on independent components (ICs) obtained through Infomax ICA and requires no manual component labelling, with per- formance governed by a single tunable threshold. It exploits the observation that CI artifacts temporally follow the audio signal without delay, whereas neural responses have an inherent lag due to auditory pathway latencies. For each IC, CORSICA com- putes the cross-correlation with the speech stimulus. Artifacts are identified by a high signal-to-noise ratio (SNR) of the correlation peak near zero lag, and the component is rejected if this SNR exceeds a threshold. To benchmark CORSICA, we evaluate two alternatives: a TRF-based SNR method, in which temporal response functions are fitted to each IC and artifact-driven peaks near zero lag are used for rejection, and a variant replacing ICA with second-order blind identification (SOBI) as the source separation step. MAIN RESULTS: CORSICA effectively suppressed CI artifacts while preserving neural activity, enabling recovery of physiologically plausible TRFs with only 2% of ICs rejected. Both benchmark methods confirmed the validity of the SNR- based rejection framework, but CORSICA outperformed the TRF-based alternative in artifact suppression quality. Replacing ICA with SOBI as the source separation step required more ICs to be rejected, further supporting ICA as the preferred backbone for CORSICA. SIGNIFICANCE: CORSICA provides a fully objective, label-free approach to identifying CI artifacts in speech-evoked EEG data, with no manual intervention required. By centering artifact rejection on a single interpretable threshold, it offers a reproducible preprocessing standard for future EEG studies on speech processing in CI users. CONCLUSION: Our findings demonstrate that objective CI artifact suppres- sion in speech-evoked EEG data is feasible on the basis of the IC's temporal response patterns.

Journal of Neural Engineering
Friedrich-Alexander-Universität Erlangen-Nürnberg (DE), University Hospital Carl Gustav Carus (DE)
Openalex Percentile: Top 22%
Hearing Loss and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.