Exceptional-Point-Enhanced Chiral Spoof Localized Surface Plasmon Resonator for Sub-Microliter Glucose Microwave Biosensing

Microwave resonance sensors are promising for dielectric characterization and biochemical detection. However, their sensing performance is constrained by the relatively long wavelength at microwave frequencies and the limited electromagnetic interaction with small-volume samples. In this paper, an exceptional-point (EP)-enhanced chiral spoof localized surface plasmon (SLSP) resonator is proposed for high sensitivity microwave biosensing with sub-microliter sample volumes. By rotating the chiral resonator relative to the microstrip feeding line, two EPs are obtained at α = 49° and α = 210°. The simulated results show that the EP states generate larger frequency splitting than the reference state under both dielectric-constant variation and detection-limit evaluation, confirming the squareroot response to weak perturbations. Experiments further validate the sensing performance using low-loss dielectric materials and high-loss glucose solutions. For dielectric samples with relative permittivities from 2 to 6.15, the frequency splitting increases from 0.287 GHz to 0.359 GHz. For glucose solutions, the frequency splitting decreases from 1.506 GHz to 1.372 GHz as the glucose amount increases from 2.78 nmol to 27.8 nmol. The proposed sensor requires only about 0.5 μL of sample volume and shows higher sensitivity than reported microwave glucose sensors. These results demonstrate that the EP-enhanced chiral SLSP resonator provides a compact and sensitive platform for trace-volume biochemical detection and integrated microwave biosensing.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2026-07-30
DOI
https://doi.org/10.3390/bios16080411
Primary Topic
Microwave and Dielectric Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exceptional-Point-Enhanced Chiral Spoof Localized Surface Plasmon Resonator for Sub-Microliter Glucose Microwave Biosensing

Zengxiang Wang, Xiaojun Huang, Zhaoyang Wang, Cuizhen Sun et al.
Biosensors
Microwave and Dielectric Measurement Techniques
article

Exceptional-Point-Enhanced Chiral Spoof Localized Surface Plasmon Resonator for Sub-Microliter Glucose Microwave Biosensing

Zengxiang Wang, Xiaojun Huang, Zhaoyang Wang, Cuizhen Sun, Xia Xiao, Wenfei Mo
article en

Abstract

Microwave resonance sensors are promising for dielectric characterization and biochemical detection. However, their sensing performance is constrained by the relatively long wavelength at microwave frequencies and the limited electromagnetic interaction with small-volume samples. In this paper, an exceptional-point (EP)-enhanced chiral spoof localized surface plasmon (SLSP) resonator is proposed for high sensitivity microwave biosensing with sub-microliter sample volumes. By rotating the chiral resonator relative to the microstrip feeding line, two EPs are obtained at α = 49° and α = 210°. The simulated results show that the EP states generate larger frequency splitting than the reference state under both dielectric-constant variation and detection-limit evaluation, confirming the squareroot response to weak perturbations. Experiments further validate the sensing performance using low-loss dielectric materials and high-loss glucose solutions. For dielectric samples with relative permittivities from 2 to 6.15, the frequency splitting increases from 0.287 GHz to 0.359 GHz. For glucose solutions, the frequency splitting decreases from 1.506 GHz to 1.372 GHz as the glucose amount increases from 2.78 nmol to 27.8 nmol. The proposed sensor requires only about 0.5 μL of sample volume and shows higher sensitivity than reported microwave glucose sensors. These results demonstrate that the EP-enhanced chiral SLSP resonator provides a compact and sensitive platform for trace-volume biochemical detection and integrated microwave biosensing.

BiosensorsVol. 16(8)
Xi'an University of Science and Technology (CN), Tianjin University of Technology (CN), Tianjin University (CN), Nankai University (CN), Zhengzhou University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 16%
Microwave and Dielectric Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.