EEG spectral biomarkers of postoperative delirium in spinal surgery: A high-resolution analysis

BACKGROUND: Postoperative delirium is common in older adults following spinal surgery, yet current EEG-based detection methods rely on broad conventional frequency bands that may obscure clinically meaningful oscillatory changes. More granular spectral approaches may reveal candidate frequency-specific features that could improve diagnostic performance. METHODS: We recorded single-electrode frontal EEG (Fp1) from 47 patients at four perioperative timepoints and compared traditional band-level power with high-resolution 1-Hz spectral analysis (1-45 Hz). Group differences were evaluated using non-parametric statistics with FDR correction, and diagnostic accuracy was assessed using AUROC and threshold-optimized metrics. All diagnostics thresholds were derived and evaluated in the same dataset. RESULTS: Seven patients (14.9%) developed delirium. Conventional band analysis detected only reduced theta power during active delirium (|r| = 0.31; AUROC = 0.53). In contrast, 1-Hz analysis revealed a richer pattern: elevated 1-Hz power (|r| = 0.27), reduced 3-7 Hz power (|r| = 0.25-0.27), and increased 14-15 Hz power (|r| = 0.22-0.26). The 23-Hz narrow-band feature achieved the best discrimination (AUROC = 0.74), despite showing no significant effect within the traditional beta band (12-30 Hz). Several frequencies remained altered even after clinical resolution of delirium. CONCLUSIONS: In this exploratory analysis, high-resolution spectral analysis identified candidate frequency-specific EEG features that distinguished delirium cases more accurately than conventional frequency bands in this cohort. Broadband averaging may not detect frequency-specific oscillatory patterns; adopting finer spectral resolution could enhance the utility of single-channel EEG for routine clinical monitoring.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2026-07-30
DOI
https://doi.org/10.1371/journal.pone.0352607
Primary Topic
Intensive Care Unit Cognitive Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EEG spectral biomarkers of postoperative delirium in spinal surgery: A high-resolution analysis

Masaya Nakamura, Hiroyoshi Takeuchi, Yasue Mitsukura, Guoxin Lin et al.
PLoS ONE
Intensive Care Unit Cognitive Disorders
article

EEG spectral biomarkers of postoperative delirium in spinal surgery: A high-resolution analysis

Masaya Nakamura, Hiroyoshi Takeuchi, Yasue Mitsukura, Guoxin Lin, Kota Watanabe, Satoshi Suzuki, Takahito Uchida
article en

Abstract

BACKGROUND: Postoperative delirium is common in older adults following spinal surgery, yet current EEG-based detection methods rely on broad conventional frequency bands that may obscure clinically meaningful oscillatory changes. More granular spectral approaches may reveal candidate frequency-specific features that could improve diagnostic performance. METHODS: We recorded single-electrode frontal EEG (Fp1) from 47 patients at four perioperative timepoints and compared traditional band-level power with high-resolution 1-Hz spectral analysis (1-45 Hz). Group differences were evaluated using non-parametric statistics with FDR correction, and diagnostic accuracy was assessed using AUROC and threshold-optimized metrics. All diagnostics thresholds were derived and evaluated in the same dataset. RESULTS: Seven patients (14.9%) developed delirium. Conventional band analysis detected only reduced theta power during active delirium (|r| = 0.31; AUROC = 0.53). In contrast, 1-Hz analysis revealed a richer pattern: elevated 1-Hz power (|r| = 0.27), reduced 3-7 Hz power (|r| = 0.25-0.27), and increased 14-15 Hz power (|r| = 0.22-0.26). The 23-Hz narrow-band feature achieved the best discrimination (AUROC = 0.74), despite showing no significant effect within the traditional beta band (12-30 Hz). Several frequencies remained altered even after clinical resolution of delirium. CONCLUSIONS: In this exploratory analysis, high-resolution spectral analysis identified candidate frequency-specific EEG features that distinguished delirium cases more accurately than conventional frequency bands in this cohort. Broadband averaging may not detect frequency-specific oscillatory patterns; adopting finer spectral resolution could enhance the utility of single-channel EEG for routine clinical monitoring.

PLoS ONEVol. 21(7)
Keio University (JP), UCB Pharma (Japan) (JP)
Peace, Justice and strong institutions, Reduced inequalities
Openalex Percentile: Top 8%
Intensive Care Unit Cognitive Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.