Continuous Cuffless Blood Pressure Estimation Using a Multimodal Conv1D-LSTM Architecture and the SOUNDI® Wearable Device

Arterial blood pressure (BP) is a crucial physiological parameter reflecting cardiovascular function and exhibiting dynamic oscillations in response to physiological, psychological, and environmental changes. Since conventional cuff-based measurements provide only intermittent “snapshot” readings, there is growing interest in reliable cuffless and noninvasive systems capable of capturing BP dynamics over time. This work proposes a continuous cuffless BP estimation system based on SOUNDI®, a proprietary wearable device for multimodal physiological and environmental monitoring developed by Biocubica srl. An end-to-end neural network architecture combining convolutional and long short-term memory (LSTM) layers was designed to automatically extract features from pre-processed signals and directly predict systolic and diastolic BP (SBP and DBP). Data were collected from 20 healthy subjects (7 females, 13 males) using a tailored acquisition protocol with reference targets acquired through the validated GIMA® ABPM50 device. Model performance was evaluated using both a Leave-One-Subject-Out (LOSO) cross-validation framework to assess subject-independent generalizability and a conventional 80/20 segment-level split reflecting a personalized monitoring setup. Under the subject-independent LOSO cross-validation, the model achieved a best-subject MAE of 4.93 mmHg for SBP and 3.76 mmHg for DBP, demonstrating the feasibility of generalizing across unseen individuals despite inter-subject physiological variability. Under the conventional 80/20 split, the framework achieved an MAE of 2.98 mmHg for SBP and 2.68 mmHg for DBP, with RMSE values of 4.16 mmHg and 3.72 mmHg, respectively, and Pearson correlation coefficients of R = 0.95 for SBP and R = 0.94 for DBP. These results establish a promising feasibility proof-of-concept for multimodal cuffless BP tracking under dynamic states and nocturnal conditions, highlighting both the strength of multi-sensor fusion and the value of lightweight calibration for real-world deployment on larger, clinical cohorts.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2026-07-30
DOI
https://doi.org/10.3390/bios16080412
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Continuous Cuffless Blood Pressure Estimation Using a Multimodal Conv1D-LSTM Architecture and the SOUNDI® Wearable Device

Dario Bovio, Caterina Salito, Pietro Cerveri, Alberto Porro et al.
Biosensors
Non-Invasive Vital Sign Monitoring
article

Continuous Cuffless Blood Pressure Estimation Using a Multimodal Conv1D-LSTM Architecture and the SOUNDI® Wearable Device

Dario Bovio, Caterina Salito, Pietro Cerveri, Alberto Porro, Alice Turrini, Alice Prandoni
article en

Abstract

Arterial blood pressure (BP) is a crucial physiological parameter reflecting cardiovascular function and exhibiting dynamic oscillations in response to physiological, psychological, and environmental changes. Since conventional cuff-based measurements provide only intermittent “snapshot” readings, there is growing interest in reliable cuffless and noninvasive systems capable of capturing BP dynamics over time. This work proposes a continuous cuffless BP estimation system based on SOUNDI®, a proprietary wearable device for multimodal physiological and environmental monitoring developed by Biocubica srl. An end-to-end neural network architecture combining convolutional and long short-term memory (LSTM) layers was designed to automatically extract features from pre-processed signals and directly predict systolic and diastolic BP (SBP and DBP). Data were collected from 20 healthy subjects (7 females, 13 males) using a tailored acquisition protocol with reference targets acquired through the validated GIMA® ABPM50 device. Model performance was evaluated using both a Leave-One-Subject-Out (LOSO) cross-validation framework to assess subject-independent generalizability and a conventional 80/20 segment-level split reflecting a personalized monitoring setup. Under the subject-independent LOSO cross-validation, the model achieved a best-subject MAE of 4.93 mmHg for SBP and 3.76 mmHg for DBP, demonstrating the feasibility of generalizing across unseen individuals despite inter-subject physiological variability. Under the conventional 80/20 split, the framework achieved an MAE of 2.98 mmHg for SBP and 2.68 mmHg for DBP, with RMSE values of 4.16 mmHg and 3.72 mmHg, respectively, and Pearson correlation coefficients of R = 0.95 for SBP and R = 0.94 for DBP. These results establish a promising feasibility proof-of-concept for multimodal cuffless BP tracking under dynamic states and nocturnal conditions, highlighting both the strength of multi-sensor fusion and the value of lightweight calibration for real-world deployment on larger, clinical cohorts.

BiosensorsVol. 16(8)
University of Pavia (IT), Biogen (Italy) (IT), Politecnico di Milano (IT)
Openalex Percentile: Top 17%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.