Validity and Sensitivity of Extended Field‐of‐View Wireless Palm‐Sized Ultrasonography for Assessing Muscle Hypertrophy

ABSTRACT This study evaluated the validity and sensitivity of an extended field‐of‐view (EFOV) wireless palm‐sized ultrasound device for assessing quadriceps femoris cross‐sectional area (CSA), using magnetic resonance imaging (MRI) as the reference. Although previous studies have examined EFOV ultrasound, data validating EFOV wireless palm‐sized devices against MRI using large cohorts and training interventions have not been reported. In Experiment 1, midthigh CSA was measured in 100 young adults (75 males, 25 females) using ultrasound and MRI. Intra‐rater reliability was assessed via intraclass correlation coefficients (ICC), standard error of measurement (SEM), coefficient of variation (CV), and smallest detectable change (SDC). In Experiment 2, 11 males underwent an 8‐week resistance training program. Pre‐to‐post changes in CSA (ΔCSA) were compared between the two imaging modalities. In Experiment 1, the device demonstrated excellent reliability for males (ICC = 0.996; SEM = 0.85 cm 2 ; CV = 1.19%; SDC = 2.35 cm 2 ) and females (ICC = 0.993; SEM = 0.95 cm 2 ; CV = 1.73%; SDC = 2.63 cm 2 ). A strong correlation ( r = 0.98, p < 0.001) was observed between ultrasound and MRI, with a mean bias of −1.23 ± 2.70 cm 2 . In Experiment 2, both modalities detected significant hypertrophy ( p < 0.001). The mean ΔCSA measured by ultrasound (3.77 cm 2 , 5.98%) exceeded the SDC (2.35 cm 2 ). ΔCSA correlated strongly between modalities ( r = 0.92, p < 0.001). The EFOV wireless palm‐sized ultrasound device is a valid and sensitive tool for quantifying quadriceps femoris CSA and monitoring muscle adaptations, suitable for athletic performance and clinical settings.

Authors

Institutions

Publication Details

Journal
European Journal of Sport Science
Published
2026-07-30
DOI
https://doi.org/10.1002/ejsc.70234
Primary Topic
Sports injuries and prevention
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validity and Sensitivity of Extended Field‐of‐View Wireless Palm‐Sized Ultrasonography for Assessing Muscle Hypertrophy

Yuto Hashimoto, Mizuki Sudo, Takanobu Okamoto, Soichi Ando et al.
European Journal of Sport Science
Sports injuries and prevention
article

Validity and Sensitivity of Extended Field‐of‐View Wireless Palm‐Sized Ultrasonography for Assessing Muscle Hypertrophy

Yuto Hashimoto, Mizuki Sudo, Takanobu Okamoto, Soichi Ando, Madoka Ogawa, Sari Kanbayashi, Tatsuki Fukumitsu
article en

Abstract

ABSTRACT This study evaluated the validity and sensitivity of an extended field‐of‐view (EFOV) wireless palm‐sized ultrasound device for assessing quadriceps femoris cross‐sectional area (CSA), using magnetic resonance imaging (MRI) as the reference. Although previous studies have examined EFOV ultrasound, data validating EFOV wireless palm‐sized devices against MRI using large cohorts and training interventions have not been reported. In Experiment 1, midthigh CSA was measured in 100 young adults (75 males, 25 females) using ultrasound and MRI. Intra‐rater reliability was assessed via intraclass correlation coefficients (ICC), standard error of measurement (SEM), coefficient of variation (CV), and smallest detectable change (SDC). In Experiment 2, 11 males underwent an 8‐week resistance training program. Pre‐to‐post changes in CSA (ΔCSA) were compared between the two imaging modalities. In Experiment 1, the device demonstrated excellent reliability for males (ICC = 0.996; SEM = 0.85 cm 2 ; CV = 1.19%; SDC = 2.35 cm 2 ) and females (ICC = 0.993; SEM = 0.95 cm 2 ; CV = 1.73%; SDC = 2.63 cm 2 ). A strong correlation ( r = 0.98, p < 0.001) was observed between ultrasound and MRI, with a mean bias of −1.23 ± 2.70 cm 2 . In Experiment 2, both modalities detected significant hypertrophy ( p < 0.001). The mean ΔCSA measured by ultrasound (3.77 cm 2 , 5.98%) exceeded the SDC (2.35 cm 2 ). ΔCSA correlated strongly between modalities ( r = 0.92, p < 0.001). The EFOV wireless palm‐sized ultrasound device is a valid and sensitive tool for quantifying quadriceps femoris CSA and monitoring muscle adaptations, suitable for athletic performance and clinical settings.

European Journal of Sport ScienceVol. 26(8)
Tokyo University of the Arts (JP), University of Electro-Communications (JP), Meiji Yasuda Life Foundation of Health and Welfare (JP), Nippon Sport Science University (JP)
Descente and Ishimoto Memorial Foundation for the Promotion of Sports Science, Japan Society for the Promotion of Science
Openalex Percentile: Top 8%
Sports injuries and prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.