Diagnostic yield and complication rate of transbronchial lung cryobiopsy using 1.1 mm probe in patients with interstitial lung disease

BACKGROUND: Widespread adoption of transbronchial lung cryobiopsy (TBLC) using a 1.9 or 2.4 mm touch cryoprobe in interstitial lung disease (ILD) has been limited by high bleeding risk. Recent studies have demonstrated that the 1.1 mm cryoprobe via conventional bronchoscope may achieve diagnostic yields comparable to larger probes while maintaining a favorable safety profile. Studies of the 1.1 mm touch cryoprobe in the diagnosis of ILD have been flawed and conflicting. AIM: The aim of this study is to describe the complication rate, diagnostic yield, and factors that increase diagnostic yield of TBLC using a 1.1 mm touch cryoprobe in patients with ILD. METHODS: The retrospective cohort study included patients that were prospectively identified in the ILD clinic registry at University of Texas Southwestern Medical Center (UTSW) who underwent TBLC from 2022-2026. Procedural characteristics were recorded. Patients were assigned a pre-TBLC, post-TBLC, and final diagnosis. RESULTS: This study demonstrates that TBLC using a 1.1 mm probe added to BAL significantly increases diagnostic yield with an 11% risk of pneumothorax and a 6.5% risk of bleeding. The combination of BAL and TBLC was diagnostic in 27 (43.5%) of patients and led to a change in diagnosis in 27 (43.5%) of patients. The number of TBLC samples taken is associated with a higher diagnostic yield. CONCLUSION: The diagnostic yield and complication rates of the 1.1 mm touch probe in our study are higher than previously reported studies with TBBx but lower than 1.9 and 2.4 mm touch probes, though there was no direct comparison group in our study. To increase yield of the procedure, multiple lobes should be biopsied and more samples taken.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2026-07-30
DOI
https://doi.org/10.1371/journal.pone.0354460
Primary Topic
Interstitial Lung Diseases and Idiopathic Pulmonary Fibrosis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic yield and complication rate of transbronchial lung cryobiopsy using 1.1 mm probe in patients with interstitial lung disease

Kim Styrvoky, Traci N. Adams, Margaret Kypreos, Steven Wu et al.
PLoS ONE
Interstitial Lung Diseases and Idiopathic Pulmonary Fibrosis
article

Diagnostic yield and complication rate of transbronchial lung cryobiopsy using 1.1 mm probe in patients with interstitial lung disease

Kim Styrvoky, Traci N. Adams, Margaret Kypreos, Steven Wu, Audra Schwalk
article en

Abstract

BACKGROUND: Widespread adoption of transbronchial lung cryobiopsy (TBLC) using a 1.9 or 2.4 mm touch cryoprobe in interstitial lung disease (ILD) has been limited by high bleeding risk. Recent studies have demonstrated that the 1.1 mm cryoprobe via conventional bronchoscope may achieve diagnostic yields comparable to larger probes while maintaining a favorable safety profile. Studies of the 1.1 mm touch cryoprobe in the diagnosis of ILD have been flawed and conflicting. AIM: The aim of this study is to describe the complication rate, diagnostic yield, and factors that increase diagnostic yield of TBLC using a 1.1 mm touch cryoprobe in patients with ILD. METHODS: The retrospective cohort study included patients that were prospectively identified in the ILD clinic registry at University of Texas Southwestern Medical Center (UTSW) who underwent TBLC from 2022-2026. Procedural characteristics were recorded. Patients were assigned a pre-TBLC, post-TBLC, and final diagnosis. RESULTS: This study demonstrates that TBLC using a 1.1 mm probe added to BAL significantly increases diagnostic yield with an 11% risk of pneumothorax and a 6.5% risk of bleeding. The combination of BAL and TBLC was diagnostic in 27 (43.5%) of patients and led to a change in diagnosis in 27 (43.5%) of patients. The number of TBLC samples taken is associated with a higher diagnostic yield. CONCLUSION: The diagnostic yield and complication rates of the 1.1 mm touch probe in our study are higher than previously reported studies with TBBx but lower than 1.9 and 2.4 mm touch probes, though there was no direct comparison group in our study. To increase yield of the procedure, multiple lobes should be biopsied and more samples taken.

PLoS ONEVol. 21(7)
Orlando Health (US), Florida Hospital Cancer Institute (US), The University of Texas Southwestern Medical Center (US)
Good health and well-being
Openalex Percentile: Top 10%
Interstitial Lung Diseases and Idiopathic Pulmonary Fibrosis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.