Beyond Accuracy: A Stability‐Focused Framework for Raman Spectroscopic Margin Assessment

ABSTRACT High classification accuracy alone does not guarantee reliable intraoperative margin assessment, particularly for Raman spectroscopic diagnostics that are sensitive to spatial heterogeneity and sampling variability. This study systematically examines how spectral averaging, spatial sampling design, and training cohort composition affect the stability and generalizability of Raman mapping‐based tissue classification for tongue squamous cell carcinoma. Raman mapping data were acquired from paired tumor and adjacent normal tissues, followed by two‐dimensional spatial averaging across multiple integration scales. A range of conventional machine learning and deep learning models were evaluated, with XGBoost and ResNet selected for controlled comparisons. Model performance was assessed under varying window sizes, sampling strategies, and training cohort compositions using repeated cross‐validation. Increasing the spatial averaging scale led to a systematic improvement in discrimination performance, with mean AUC rising rapidly at small window sizes and approaching saturation at larger scales, while performance variability showed no systematic dependence on window size. Interleaved spatial sampling consistently improved robustness to intratissue heterogeneity. Expanding the training cohort from five to 10 patients markedly enhanced cross‐patient generalization, with no repeated trial falling below a clinically relevant threshold (AUC ≥ 0.90). While both models achieved comparable average accuracy, XGBoost exhibited greater stability under limited training data. Rather than introducing new classification architectures, this work defines quantitative parameter regimes that balance accuracy, stability, and feasibility, providing a stability‐oriented framework to support the clinical translation of Raman spectroscopic margin assessment.

Authors

Institutions

Publication Details

Journal
Journal of Raman Spectroscopy
Published
2026-07-30
DOI
https://doi.org/10.1002/jrs.70201
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Beyond Accuracy: A Stability‐Focused Framework for Raman Spectroscopic Margin Assessment

Zhining Wen, Song Zhai, Chengxiang Ru, Yuan Liu et al.
Journal of Raman Spectroscopy
Spectroscopy Techniques in Biomedical and Chemical Research
article

Beyond Accuracy: A Stability‐Focused Framework for Raman Spectroscopic Margin Assessment

Zhining Wen, Song Zhai, Chengxiang Ru, Yuan Liu, Yixi Huang, Lei Zhou, Bing Yan, Zifan Lin, Ran You
article en

Abstract

ABSTRACT High classification accuracy alone does not guarantee reliable intraoperative margin assessment, particularly for Raman spectroscopic diagnostics that are sensitive to spatial heterogeneity and sampling variability. This study systematically examines how spectral averaging, spatial sampling design, and training cohort composition affect the stability and generalizability of Raman mapping‐based tissue classification for tongue squamous cell carcinoma. Raman mapping data were acquired from paired tumor and adjacent normal tissues, followed by two‐dimensional spatial averaging across multiple integration scales. A range of conventional machine learning and deep learning models were evaluated, with XGBoost and ResNet selected for controlled comparisons. Model performance was assessed under varying window sizes, sampling strategies, and training cohort compositions using repeated cross‐validation. Increasing the spatial averaging scale led to a systematic improvement in discrimination performance, with mean AUC rising rapidly at small window sizes and approaching saturation at larger scales, while performance variability showed no systematic dependence on window size. Interleaved spatial sampling consistently improved robustness to intratissue heterogeneity. Expanding the training cohort from five to 10 patients markedly enhanced cross‐patient generalization, with no repeated trial falling below a clinically relevant threshold (AUC ≥ 0.90). While both models achieved comparable average accuracy, XGBoost exhibited greater stability under limited training data. Rather than introducing new classification architectures, this work defines quantitative parameter regimes that balance accuracy, stability, and feasibility, providing a stability‐oriented framework to support the clinical translation of Raman spectroscopic margin assessment.

Journal of Raman Spectroscopy
Sichuan University (CN)
National Natural Science Foundation of China, Natural Science Foundation of Sichuan Province
Reduced inequalities
Openalex Percentile: Top 10%
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.