Evaluation of Warming Methods for Neonatal Puppies

Maintaining appropriate nest temperatures during the first weeks of life is essential because neonatal puppies have limited thermoregulatory capacity. Commonly used warming methods in breeding and veterinary settings, including infrared heat lamps and electric heating pads, may produce uneven heating, unstable temperature regulation, or temperatures that are difficult to measure accurately. This study evaluated the performance and temperature measurement characteristics of commonly used neonatal puppy warming methods and compared them with a thermostatically controlled water warming system. Temperature stability, surface uniformity, and differences among temperature measurement methods were evaluated under standardized environmental conditions using Type K thermocouples, handheld infrared thermometers, digital surface thermometers, and infrared thermal imaging. Infrared-heated surfaces demonstrated substantial variation in measured temperatures depending on the measurement method and surface characteristics. Electric heating pads exhibited significantly higher surface temperatures (p < 0.05), localized hot spots, and greater temperature fluctuations than desired for neonatal thermal support. In contrast, the recirculating water warming system demonstrated greater temperature stability and more uniform heating than the other methods evaluated, with adjacent fleece temperatures maintained within the target neonatal nest temperature range.

Authors

Publication Details

Journal
Preprints.org
Published
2026-08-20
DOI
https://doi.org/10.20944/preprints202608.1390.v1
Primary Topic
Thermal Regulation in Medicine
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Evaluation of Warming Methods for Neonatal Puppies

Connie or Constance Van Schaick
Preprints.org
Thermal Regulation in Medicine
preprint

Evaluation of Warming Methods for Neonatal Puppies

Connie or Constance Van Schaick
preprint en

Abstract

Maintaining appropriate nest temperatures during the first weeks of life is essential because neonatal puppies have limited thermoregulatory capacity. Commonly used warming methods in breeding and veterinary settings, including infrared heat lamps and electric heating pads, may produce uneven heating, unstable temperature regulation, or temperatures that are difficult to measure accurately. This study evaluated the performance and temperature measurement characteristics of commonly used neonatal puppy warming methods and compared them with a thermostatically controlled water warming system. Temperature stability, surface uniformity, and differences among temperature measurement methods were evaluated under standardized environmental conditions using Type K thermocouples, handheld infrared thermometers, digital surface thermometers, and infrared thermal imaging. Infrared-heated surfaces demonstrated substantial variation in measured temperatures depending on the measurement method and surface characteristics. Electric heating pads exhibited significantly higher surface temperatures (p < 0.05), localized hot spots, and greater temperature fluctuations than desired for neonatal thermal support. In contrast, the recirculating water warming system demonstrated greater temperature stability and more uniform heating than the other methods evaluated, with adjacent fleece temperatures maintained within the target neonatal nest temperature range.

Preprints.org
Thermal Regulation in Medicine
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.