Standalone use of EAHEs for room cooling is a passive and nature-based alternative to air conditioning technology that can be used to mitigate the increase in electricity and GWP-refrigerant consumption associated with cooling in buildings. EAHEs replacing air conditioning is documented in the technical and research literature. However, for office-room cooling, EAHEs are mostly employed as a support to air conditioning systems for precooling outdoor air. The larger cooling loads and the stricter design conditions commonly used in the sizing of office rooms prevent the most commonly investigated EAHE typologies from operating effectively in standalone cooling mode. To assess the feasibility of alternative typologies, such as large-diameter EAHEs, tools that are capable of modeling the complexity of the coupled heat and moisture transfer between air and soil are particularly valuable. For detailed assessments, researchers typically turn to advanced commercial tools; however, developments in free and open-source scientific programming languages that combine symbolic computation packages with efficient numerical solvers of partial differential equations allow analyses at reduced cost that are comparable to those from commercial tools. This paper shows how one such programming language can be used to study the coupled heat and moisture transfer problem in EAHEs. Starting from the symbolic form of the mathematical problem, the numerical implementation is described and validated with monitoring data from an existing large-diameter EAHE. Using the validated computational model, the paper proceeds to study the sensitivity of load removal in EAHEs operating in standalone and precooling cooling modes, highlighting fundamental differences between both operating modes, identifying the most relevant design parameters and providing guidance on the conditions under which an EAHE enables self-sufficient cooling of office buildings. The results show how, for a hot and dry climate, standalone EAHEs with large diameters (∼1 m), buried at depths larger than 3 m, allow the removal of up to 20 kWh/m2 of room sensible cooling loads, a level that is consistent with the cooling demand of low-energy office buildings.

Authors

Institutions

Publication Details

Journal
Applied System Innovation
Published
2026-07-28
DOI
https://doi.org/10.3390/asi9080160
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigating the Use of Large-Diameter Earth–Air Heat Exchangers to Achieve Office Building Cooling Self-Sufficiency

Rogério Duarte, Amândio Rebola, Luís Coelho
Applied System Innovation
Geothermal Energy Systems and Applications
article

Investigating the Use of Large-Diameter Earth–Air Heat Exchangers to Achieve Office Building Cooling Self-Sufficiency

Rogério Duarte, Amândio Rebola, Luís Coelho
article en

Abstract

Standalone use of EAHEs for room cooling is a passive and nature-based alternative to air conditioning technology that can be used to mitigate the increase in electricity and GWP-refrigerant consumption associated with cooling in buildings. EAHEs replacing air conditioning is documented in the technical and research literature. However, for office-room cooling, EAHEs are mostly employed as a support to air conditioning systems for precooling outdoor air. The larger cooling loads and the stricter design conditions commonly used in the sizing of office rooms prevent the most commonly investigated EAHE typologies from operating effectively in standalone cooling mode. To assess the feasibility of alternative typologies, such as large-diameter EAHEs, tools that are capable of modeling the complexity of the coupled heat and moisture transfer between air and soil are particularly valuable. For detailed assessments, researchers typically turn to advanced commercial tools; however, developments in free and open-source scientific programming languages that combine symbolic computation packages with efficient numerical solvers of partial differential equations allow analyses at reduced cost that are comparable to those from commercial tools. This paper shows how one such programming language can be used to study the coupled heat and moisture transfer problem in EAHEs. Starting from the symbolic form of the mathematical problem, the numerical implementation is described and validated with monitoring data from an existing large-diameter EAHE. Using the validated computational model, the paper proceeds to study the sensitivity of load removal in EAHEs operating in standalone and precooling cooling modes, highlighting fundamental differences between both operating modes, identifying the most relevant design parameters and providing guidance on the conditions under which an EAHE enables self-sufficient cooling of office buildings. The results show how, for a hot and dry climate, standalone EAHEs with large diameters (∼1 m), buried at depths larger than 3 m, allow the removal of up to 20 kWh/m2 of room sensible cooling loads, a level that is consistent with the cooling demand of low-energy office buildings.

Applied System InnovationVol. 9(8)
Universidade Politécnica de Setúbal (PT)
Openalex Percentile: Top 24%
Geothermal Energy Systems and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.