Beyond Directions: Symmetry‐Aware Rotation Sets for Triaxial Diffusion Encoding by Geometric Filter Optimization

ABSTRACT Purpose To improve the accuracy of diffusion‐weighted powder average signals for diffusion encoding with arbitrary b‐tensors. Methods We identify an intrinsic dihedral () symmetry of diffusion signals for arbitrary diffusion encoding, which defines their natural signal space (a quotient of 3D rotations). Based on this, we propose a method to generate optimal rotation sets that are applied to the diffusion‐encoding gradient waveform to yield powder averages with maximal accuracy. The method, termed “Geometric Filter Optimization” (GFO), amounts to designing a sampling filter that is approximately flat over the relevant part of the associated frequency space. We characterize the filter properties and benchmark performance in terms of the accuracy and precision of powder averages and higher‐order rotational invariants, including comparison with spherical designs and electrostatic‐repulsion‐based designs defined on the same space. Results We found that GFO leads to marked improvements in precision and accuracy in powder averaging over diffusion encoding b‐tensors, including axisymmetric and triaxial configurations. For higher‐order rotational invariants, the performance was more nuanced, with GFO, electrostatic repulsion, and spherical designs exhibiting different trade‐offs in bias and precision depending on and . Conclusion A fundamental ‐symmetry of tensor‐valued diffusion encoding was shown to constrain its rotational structure and guide the design of optimal rotation sets. This yielded GFO, which provides an efficient recipe for obtaining orientations for powder averaging of signals with axisymmetric and triaxial diffusion encoding. It places no additional demands on gradient system performance and can be used to shorten scan time.

Authors

Institutions

Publication Details

Journal
Magnetic Resonance in Medicine
Published
2026-07-28
DOI
https://doi.org/10.1002/mrm.70489
Primary Topic
Advanced Neuroimaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Beyond Directions: Symmetry‐Aware Rotation Sets for Triaxial Diffusion Encoding by Geometric Filter Optimization

Sune Nørhøj Jespersen, Filip Szczepankiewicz
Magnetic Resonance in Medicine
Advanced Neuroimaging Techniques and Applications
article

Beyond Directions: Symmetry‐Aware Rotation Sets for Triaxial Diffusion Encoding by Geometric Filter Optimization

Sune Nørhøj Jespersen, Filip Szczepankiewicz
article en

Abstract

ABSTRACT Purpose To improve the accuracy of diffusion‐weighted powder average signals for diffusion encoding with arbitrary b‐tensors. Methods We identify an intrinsic dihedral () symmetry of diffusion signals for arbitrary diffusion encoding, which defines their natural signal space (a quotient of 3D rotations). Based on this, we propose a method to generate optimal rotation sets that are applied to the diffusion‐encoding gradient waveform to yield powder averages with maximal accuracy. The method, termed “Geometric Filter Optimization” (GFO), amounts to designing a sampling filter that is approximately flat over the relevant part of the associated frequency space. We characterize the filter properties and benchmark performance in terms of the accuracy and precision of powder averages and higher‐order rotational invariants, including comparison with spherical designs and electrostatic‐repulsion‐based designs defined on the same space. Results We found that GFO leads to marked improvements in precision and accuracy in powder averaging over diffusion encoding b‐tensors, including axisymmetric and triaxial configurations. For higher‐order rotational invariants, the performance was more nuanced, with GFO, electrostatic repulsion, and spherical designs exhibiting different trade‐offs in bias and precision depending on and . Conclusion A fundamental ‐symmetry of tensor‐valued diffusion encoding was shown to constrain its rotational structure and guide the design of optimal rotation sets. This yielded GFO, which provides an efficient recipe for obtaining orientations for powder averaging of signals with axisymmetric and triaxial diffusion encoding. It places no additional demands on gradient system performance and can be used to shorten scan time.

Magnetic Resonance in Medicine
Lund University (SE), Aarhus University (DK)
Openalex Percentile: Top 8%
Advanced Neuroimaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.