Association of HFLTVV With Force‐Time Integral and Ablation Index During Pulmonary Vein Isolation

ABSTRACT Introduction In catheter ablation of atrial fibrillation (AF), durable lesion formation is essential for successful pulmonary vein isolation (PVI). Force–time integral (FTI) is an established lesion metric that reflects the cumulative effect of contact force (CF) and radiofrequency (RF) application time and has been associated with lesion durability. Although high‐frequency low–tidal volume ventilation (HFLTVV) has been associated with improved procedural outcomes, lesion‐level evidence in the era of contact force‐guided ablation remains limited. We aimed to evaluate the association between HFLTVV and lesion metrics during PVI. Methods and Results This single‐center retrospective study included patients with paroxysmal AF undergoing first‐time RF PVI. Procedures were performed during the standard ventilation (SV) and the HFLTVV eras, with CF targeted at 10–12 g. Lesion parameters, including RF application time, average CF, ablation index (AI), FTI, and impedance drop, were extracted from CARTONET and analyzed overall and by pulmonary vein region. Respiratory effects were assessed using arterial blood gas analysis. Compared with SV, HFLTVV was associated with significantly higher FTI and AI (FTI: 268.8 ± 31.5 vs 235.2 ± 21.7 g·s; AI: 459.0 ± 16.8 vs 437.1 ± 13.4; both p <0.001), despite similar CF and RF application time. Findings were consistent across pulmonary vein regions. In multivariable analyses adjusting for baseline characteristics, HFLTVV remained independently associated with higher FTI and AI (both p <0.001). Procedural duration and arrhythmia recurrence were similar between groups. Arterial blood gas analysis demonstrated no clinically significant CO 2 retention. Conclusion HFLTVV was associated with higher FTI and AI under comparable CF and RF application time. These findings suggest that HFLTVV may influence lesion metrics during AF ablation and warrant further investigation.

Authors

Institutions

Publication Details

Journal
Pacing and Clinical Electrophysiology
Published
2026-07-28
DOI
https://doi.org/10.1111/pace.70380
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Association of HFLTVV With Force‐Time Integral and Ablation Index During Pulmonary Vein Isolation

Kimikazu Banba, Tatsuya Shigematsu, Yutaka Take, Masato Takeuchi et al.
Pacing and Clinical Electrophysiology
Atrial Fibrillation Management and Outcomes
article

Association of HFLTVV With Force‐Time Integral and Ablation Index During Pulmonary Vein Isolation

Kimikazu Banba, Tatsuya Shigematsu, Yutaka Take, Masato Takeuchi, Natsuki Kanazawa, Motomi Tachibana, Seiji Moriya
article en

Abstract

ABSTRACT Introduction In catheter ablation of atrial fibrillation (AF), durable lesion formation is essential for successful pulmonary vein isolation (PVI). Force–time integral (FTI) is an established lesion metric that reflects the cumulative effect of contact force (CF) and radiofrequency (RF) application time and has been associated with lesion durability. Although high‐frequency low–tidal volume ventilation (HFLTVV) has been associated with improved procedural outcomes, lesion‐level evidence in the era of contact force‐guided ablation remains limited. We aimed to evaluate the association between HFLTVV and lesion metrics during PVI. Methods and Results This single‐center retrospective study included patients with paroxysmal AF undergoing first‐time RF PVI. Procedures were performed during the standard ventilation (SV) and the HFLTVV eras, with CF targeted at 10–12 g. Lesion parameters, including RF application time, average CF, ablation index (AI), FTI, and impedance drop, were extracted from CARTONET and analyzed overall and by pulmonary vein region. Respiratory effects were assessed using arterial blood gas analysis. Compared with SV, HFLTVV was associated with significantly higher FTI and AI (FTI: 268.8 ± 31.5 vs 235.2 ± 21.7 g·s; AI: 459.0 ± 16.8 vs 437.1 ± 13.4; both p <0.001), despite similar CF and RF application time. Findings were consistent across pulmonary vein regions. In multivariable analyses adjusting for baseline characteristics, HFLTVV remained independently associated with higher FTI and AI (both p <0.001). Procedural duration and arrhythmia recurrence were similar between groups. Arterial blood gas analysis demonstrated no clinically significant CO 2 retention. Conclusion HFLTVV was associated with higher FTI and AI under comparable CF and RF application time. These findings suggest that HFLTVV may influence lesion metrics during AF ablation and warrant further investigation.

Pacing and Clinical Electrophysiology
Sakakibara Hospital (JP)
Openalex Percentile: Top 8%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.