Accurate estimation of intravoxel incoherent motion parameters based on implicit neural representation

Abstract Background Intravoxel incoherent motion (IVIM) diffusion‐weighted imaging has important value in treatment response monitoring. However, traditional voxel‐wise independent fitting methods are highly sensitive to noise and do not utilize spatial correlation, resulting in unstable parameter estimation. Although existing deep learning methods have shown improvements, they are still limited by local receptive fields. Purpose To address this, we propose a two‐stage IVIM parameter estimation framework based on Implicit Neural Representation (IVIM‐INR). Methods Our IVIM‐INR method achieves global spatial perception through coordinate encoding and enhances spatial context modeling by leveraging local 3D patch information from multi‐ b ‐value images. The first stage INR performs signal denoising, and the second stage INR accurately fits IVIM parameters. Results Evaluation on brain digital phantoms, AAPM breast IVIM‐dMRI Challenge data, and clinical Glioblastoma (GBM) patient data demonstrates significant advantages of the proposed method over existing techniques. In brain simulation data, when SNR = 50, the normalized mean absolute errors (NMAEs) in tumor regions were 0.160.10 for , 0.020.01 for , and 0.070.05 for , all lower than comparison methods. In the tumor tissues of the 100 cases from the AAPM breast IVIM‐dMRI challenge dataset, error was reduced by 58% compared to ConvNet. Intraclass correlation coefficient (ICC) analysis of real clinical data indicates that our method achieves the best performance with an ICC of in normal tissues reaching 0.629. Conclusions By combining INR's continuous function modeling capability with spatial‐aware feature design, IVIM‐INR overcomes the inherent limitations of traditional methods under noisy conditions, providing a more reliable tool for clinical IVIM quantitative analysis.

Authors

Institutions

Publication Details

Journal
Medical Physics
Published
2026-07-28
DOI
https://doi.org/10.1002/mp.70599
Primary Topic
MRI in cancer diagnosis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accurate estimation of intravoxel incoherent motion parameters based on implicit neural representation

Yen‐Peng Liao, Yan Dai, You Zhang, Yunxiang Li et al.
Medical Physics
MRI in cancer diagnosis
article

Accurate estimation of intravoxel incoherent motion parameters based on implicit neural representation

Yen‐Peng Liao, Yan Dai, You Zhang, Yunxiang Li, Jie Deng
article en

Abstract

Abstract Background Intravoxel incoherent motion (IVIM) diffusion‐weighted imaging has important value in treatment response monitoring. However, traditional voxel‐wise independent fitting methods are highly sensitive to noise and do not utilize spatial correlation, resulting in unstable parameter estimation. Although existing deep learning methods have shown improvements, they are still limited by local receptive fields. Purpose To address this, we propose a two‐stage IVIM parameter estimation framework based on Implicit Neural Representation (IVIM‐INR). Methods Our IVIM‐INR method achieves global spatial perception through coordinate encoding and enhances spatial context modeling by leveraging local 3D patch information from multi‐ b ‐value images. The first stage INR performs signal denoising, and the second stage INR accurately fits IVIM parameters. Results Evaluation on brain digital phantoms, AAPM breast IVIM‐dMRI Challenge data, and clinical Glioblastoma (GBM) patient data demonstrates significant advantages of the proposed method over existing techniques. In brain simulation data, when SNR = 50, the normalized mean absolute errors (NMAEs) in tumor regions were 0.160.10 for , 0.020.01 for , and 0.070.05 for , all lower than comparison methods. In the tumor tissues of the 100 cases from the AAPM breast IVIM‐dMRI challenge dataset, error was reduced by 58% compared to ConvNet. Intraclass correlation coefficient (ICC) analysis of real clinical data indicates that our method achieves the best performance with an ICC of in normal tissues reaching 0.629. Conclusions By combining INR's continuous function modeling capability with spatial‐aware feature design, IVIM‐INR overcomes the inherent limitations of traditional methods under noisy conditions, providing a more reliable tool for clinical IVIM quantitative analysis.

Medical PhysicsVol. 53(8)
Southwestern Medical Center (US), The University of Texas Southwestern Medical Center (US)
Openalex Percentile: Top 8%
MRI in cancer diagnosis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.