Effect of printing layer thickness on the mechanical properties of a direct-printed orthodontic aligner resin: An <i>in vitro</i> study

Objectives: The Objective of the study is to examine how print layer settings—50 and 100 µm affect the mechanical behavior of a clinically used direct-printed aligner resin. Material and Methods: This in vitro study investigated how printing layer thickness influences the mechanical properties of a directly printed aligner resin (Graphy Tera Harz TA-28). A total of 60 specimens were fabricated using a Uniz Nbee printer and divided into two groups based on layer thickness (50 µm and 100 µm; n = 30 per group). Standardized specimens for tensile, flexural, and compressive testing (n = 10 per test per group) were designed from STL templates and printed under identical conditions to ensure consistency. All samples underwent uniform post-processing, including centrifugation, ultrasonic cleaning, and nitrogen-assisted UV curing. Mechanical testing was carried out using a universal testing machine in accordance with ISO standards: ISO 527-2 for tensile testing, ISO 178 for flexural testing, and ISO 604 for compressive testing. The primary outcomes were strength and modulus values for each test. Data were analyzed using independent t-tests or Mann–Whitney U tests depending on data normality, with statistical significance set at α = 0.05. Results: Compressive strength was significantly higher for the 50 µm group (2.42 ± 0.61 MPa) compared with the 100 µm group (1.84 ± 0.37 MPa; p = 0.034). Conversely, the 100 µm specimens demonstrated a higher tensile modulus (114.12 ± 44.01 MPa) than the 50 µm specimens (72.14 ± 25.8 MPa; p = 0.01). Conclusion: Layer thickness influences the mechanical behavior of the Graphy TA-28 resin. Thinner layers improved compressive performance, while thicker layers increased tensile stiffness. These findings suggest that print settings can be tailored to achieve desired aligner strength and flexibility.

Authors

Institutions

Publication Details

Journal
APOS Trends in Orthodontics
Published
2026-07-28
DOI
https://doi.org/10.25259/apos_350_2025
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of printing layer thickness on the mechanical properties of a direct-printed orthodontic aligner resin: An in vitro study

Rama Krishna Alla, Nachu Lakshmi Manojna, Nagisetti Haribabu, Lakshmi Uyyala et al.
APOS Trends in Orthodontics
Orthodontics and Dentofacial Orthopedics
article

Effect of printing layer thickness on the mechanical properties of a direct-printed orthodontic aligner resin: An in vitro study

Rama Krishna Alla, Nachu Lakshmi Manojna, Nagisetti Haribabu, Lakshmi Uyyala, Kiriti Sai Reddy Karri, Padma Priya C.V
article en

Abstract

Objectives: The Objective of the study is to examine how print layer settings—50 and 100 µm affect the mechanical behavior of a clinically used direct-printed aligner resin. Material and Methods: This in vitro study investigated how printing layer thickness influences the mechanical properties of a directly printed aligner resin (Graphy Tera Harz TA-28). A total of 60 specimens were fabricated using a Uniz Nbee printer and divided into two groups based on layer thickness (50 µm and 100 µm; n = 30 per group). Standardized specimens for tensile, flexural, and compressive testing (n = 10 per test per group) were designed from STL templates and printed under identical conditions to ensure consistency. All samples underwent uniform post-processing, including centrifugation, ultrasonic cleaning, and nitrogen-assisted UV curing. Mechanical testing was carried out using a universal testing machine in accordance with ISO standards: ISO 527-2 for tensile testing, ISO 178 for flexural testing, and ISO 604 for compressive testing. The primary outcomes were strength and modulus values for each test. Data were analyzed using independent t-tests or Mann–Whitney U tests depending on data normality, with statistical significance set at α = 0.05. Results: Compressive strength was significantly higher for the 50 µm group (2.42 ± 0.61 MPa) compared with the 100 µm group (1.84 ± 0.37 MPa; p = 0.034). Conversely, the 100 µm specimens demonstrated a higher tensile modulus (114.12 ± 44.01 MPa) than the 50 µm specimens (72.14 ± 25.8 MPa; p = 0.01). Conclusion: Layer thickness influences the mechanical behavior of the Graphy TA-28 resin. Thinner layers improved compressive performance, while thicker layers increased tensile stiffness. These findings suggest that print settings can be tailored to achieve desired aligner strength and flexibility.

APOS Trends in OrthodonticsVol. 0
MNR Dental College and Hospital (IN)
Openalex Percentile: Top 7%
Orthodontics and Dentofacial Orthopedics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.