Expanding the Toolbox of Rare Earth Quantification for Bioaccumulation Studies: Selective Lanthanide Determination Using ICP-OES and Sensitized Luminescence for High Throughput Microbial Screening

Abstract Demand for rare earth elements (REEs) is surging, with several REEs deemed “critical” due to supply chain vulnerability and ubiquitous industrial use. Thus, there is growing interest in biological separation of REEs from waste products such as coal ash, e-waste, and mine tailings, which requires accurate screening of microbial candidates for metal sequestration. Current REE analysis methods include Inductively Coupled Plasma Mass Spectrometry (ICP−MS) and the colorimetric arsenazo III assay; both however possess limitations for high throughput analysis of cell cultures. ICP−MS incurs significant operational costs while arsenazo III is indiscriminate across the lanthanide series, contributing to an analytical bottleneck for strain ranking. Developing complementary metal quantitation methods is vital for scalability and automation of microbial screening. Hydroxypyridinone chelators, 5-LIO(Me-3,2-HOPO) and 3,4,3-LI(1,2-HOPO), were examined as spectroscopic antennas for Nd3+ and Eu3+ within microbial supernatant. Notably, 5-LIO(Me-3,2-HOPO) sensitized the near-IR luminescence of Nd3+ for sub-μM quantitation. Nd3+ and Eu3+ luminescence assays exhibited strong calibration linearity (R2 = 0.99) with limits of 0.14 μM for Nd3+ and 40 nM for Eu3+, outperforming arsenazo III. This work also validated Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES) to quantify REEs for bioaccumulation experiments. ICP-OES quantitation limits (excluding Sm) were ≤33 ng mL−1 and ≤24 μg g−1 cell dry weight for supernatant and biomass respectively, with matrix effects and spike recovery documented. Bioaccumulation trials with Methylobacterium extorquens (AM1 and ΔmxaF) were used to compare ICP-OES and luminescence measurements. Overall, sensitized lanthanide luminescence and ICP-OES offer reliable, complementary approaches to existing analytical methods for REE determination.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-11-04
DOI
https://doi.org/10.1021/acs.analchem.6c05331
Primary Topic
Lanthanide and Transition Metal Complexes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Expanding the Toolbox of Rare Earth Quantification for Bioaccumulation Studies: Selective Lanthanide Determination Using ICP-OES and Sensitized Luminescence for High Throughput Microbial Screening

Saad Naseem, Norma Cecilia Martinez-Gomez, Rebecca J. Abergel, Ning Sun et al.
1 links
Analytical Chemistry
Lanthanide and Transition Metal Complexes
article

Expanding the Toolbox of Rare Earth Quantification for Bioaccumulation Studies: Selective Lanthanide Determination Using ICP-OES and Sensitized Luminescence for High Throughput Microbial Screening

Saad Naseem, Norma Cecilia Martinez-Gomez, Rebecca J. Abergel, Ning Sun, Keith S. Sellers, Trinity Reimer
article en

Abstract

Abstract Demand for rare earth elements (REEs) is surging, with several REEs deemed “critical” due to supply chain vulnerability and ubiquitous industrial use. Thus, there is growing interest in biological separation of REEs from waste products such as coal ash, e-waste, and mine tailings, which requires accurate screening of microbial candidates for metal sequestration. Current REE analysis methods include Inductively Coupled Plasma Mass Spectrometry (ICP−MS) and the colorimetric arsenazo III assay; both however possess limitations for high throughput analysis of cell cultures. ICP−MS incurs significant operational costs while arsenazo III is indiscriminate across the lanthanide series, contributing to an analytical bottleneck for strain ranking. Developing complementary metal quantitation methods is vital for scalability and automation of microbial screening. Hydroxypyridinone chelators, 5-LIO(Me-3,2-HOPO) and 3,4,3-LI(1,2-HOPO), were examined as spectroscopic antennas for Nd3+ and Eu3+ within microbial supernatant. Notably, 5-LIO(Me-3,2-HOPO) sensitized the near-IR luminescence of Nd3+ for sub-μM quantitation. Nd3+ and Eu3+ luminescence assays exhibited strong calibration linearity (R2 = 0.99) with limits of 0.14 μM for Nd3+ and 40 nM for Eu3+, outperforming arsenazo III. This work also validated Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES) to quantify REEs for bioaccumulation experiments. ICP-OES quantitation limits (excluding Sm) were ≤33 ng mL−1 and ≤24 μg g−1 cell dry weight for supernatant and biomass respectively, with matrix effects and spike recovery documented. Bioaccumulation trials with Methylobacterium extorquens (AM1 and ΔmxaF) were used to compare ICP-OES and luminescence measurements. Overall, sensitized lanthanide luminescence and ICP-OES offer reliable, complementary approaches to existing analytical methods for REE determination.

Analytical Chemistry
Lawrence Berkeley National Laboratory (US), University of California, Berkeley (US)
Responsible consumption and production
Openalex Percentile: Top 62%
Lanthanide and Transition Metal Complexes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon