Silver/Magnetite Modified Carbon Paste Electrode for Arsenic (III) Quantification

In this study, a carbon paste electrode modified with silver and magnetite nanoparticles was used to quantify arsenic via square-wave anodic stripping voltammetry. Under optimized parameters, a deposition potential of −0.4 V for a period of 70 s, the setup achieved a linear quantification range from 0 to 40 µg L−1 of As (III) (R2 = 0.982). Electrochemical characterization was performed using cyclic voltammetry and electrochemical impedance spectroscopy (EIS). The evaluated arsenic quantification framework encompasses the World Health Organization (WHO) limit and the Mexican maximum permissible level for arsenic in drinking water (10 µg L−1), as well as arsenic concentrations frequently reported in groundwater wells throughout northern Mexico. Key advantages of this electrode include its low fabrication cost, ease of operation, and analytical stability spanning a 30-day period. Additionally, selectivity tests revealed that Cu(II) masked the arsenic stripping signal at a 1:1 Cu(II): arsenic concentration ratio, whereas no modification of the target signal was observed in the presence of cadmium.

Authors

Institutions

Publication Details

Journal
Chemosensors
Published
2026-07-28
DOI
https://doi.org/10.3390/chemosensors14080174
Primary Topic
Arsenic contamination and mitigation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Silver/Magnetite Modified Carbon Paste Electrode for Arsenic (III) Quantification

Liliana Reynoso-Cuevas, José Rafael Irigoyen Campuzano, María Teresa Alarcón-Herrera, Diana E. Soto-Nájera
Chemosensors
Arsenic contamination and mitigation
article

Silver/Magnetite Modified Carbon Paste Electrode for Arsenic (III) Quantification

Liliana Reynoso-Cuevas, José Rafael Irigoyen Campuzano, María Teresa Alarcón-Herrera, Diana E. Soto-Nájera
article en

Abstract

In this study, a carbon paste electrode modified with silver and magnetite nanoparticles was used to quantify arsenic via square-wave anodic stripping voltammetry. Under optimized parameters, a deposition potential of −0.4 V for a period of 70 s, the setup achieved a linear quantification range from 0 to 40 µg L−1 of As (III) (R2 = 0.982). Electrochemical characterization was performed using cyclic voltammetry and electrochemical impedance spectroscopy (EIS). The evaluated arsenic quantification framework encompasses the World Health Organization (WHO) limit and the Mexican maximum permissible level for arsenic in drinking water (10 µg L−1), as well as arsenic concentrations frequently reported in groundwater wells throughout northern Mexico. Key advantages of this electrode include its low fabrication cost, ease of operation, and analytical stability spanning a 30-day period. Additionally, selectivity tests revealed that Cu(II) masked the arsenic stripping signal at a 1:1 Cu(II): arsenic concentration ratio, whereas no modification of the target signal was observed in the presence of cadmium.

ChemosensorsVol. 14(8)
Centro de Investigación en Materiales Avanzados (MX)
Clean water and sanitation
Openalex Percentile: Top 15%
Arsenic contamination and mitigation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.