Study on the Influence of Medium Temperature on the Performance of a Space Micropump

The present work examines how variations in working fluid temperature govern the hydrodynamic behavior of a space-rated micropump. Using perfluorotriethylamine as the operating medium, three-dimensional CFD simulations employing the SST k-ω turbulence closure were carried out across a broad thermal spectrum, and the resulting flow physics were interpreted through entropy generation analysis. Based on the entropy production theory, the influence laws of different inlet temperatures on the external characteristics, internal characteristics, and flow loss characteristics of the micropump were quantitatively analyzed. The results show that temperature mainly affects the micropump performance by changing the viscosity and density of the working fluid. At low temperatures, the fluid viscosity increases significantly, leading to increased flow resistance, intensified internal friction, reduced head and efficiency, and increased shaft power. As the temperature increases to 0 °C and above, the viscosity change tends to moderate, and the external characteristic parameters tend to stabilize. The internal characteristic analysis shows that under low-temperature conditions, the high-pressure region in the impeller area expands and the turbulent kinetic energy decreases, but the flow separation is to a certain extent suppressed. The region near the volute tongue and the impeller outer edge are the main areas of entropy production loss, and their entropy production rates increase significantly with decreasing temperature. Moreover, at low temperatures, the high entropy production regions expand from locally isolated distributions to continuous large-scale distributions. The impeller outer edge dominates total entropy production, driven by peak fluid linear velocity and intense shear interaction with the volute wall. The findings elucidate how working fluid temperature governs both the hydrodynamic performance and the irreversible loss characteristics of the micropump. These insights can directly inform the engineering design of thermal management loops intended for orbital applications under severe temperature swings.

Authors

Publication Details

Journal
Aerospace
Published
2026-07-28
DOI
https://doi.org/10.3390/aerospace13080674
Primary Topic
Microfluidic and Capillary Electrophoresis Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on the Influence of Medium Temperature on the Performance of a Space Micropump

Zhen Qu, Danyang Zhou, Lilei Miao, Zhanhai Zhang et al.
Aerospace
Microfluidic and Capillary Electrophoresis Applications
article

Study on the Influence of Medium Temperature on the Performance of a Space Micropump

Zhen Qu, Danyang Zhou, Lilei Miao, Zhanhai Zhang, Jintao Liu, Kaiyun Gu
article en

Abstract

The present work examines how variations in working fluid temperature govern the hydrodynamic behavior of a space-rated micropump. Using perfluorotriethylamine as the operating medium, three-dimensional CFD simulations employing the SST k-ω turbulence closure were carried out across a broad thermal spectrum, and the resulting flow physics were interpreted through entropy generation analysis. Based on the entropy production theory, the influence laws of different inlet temperatures on the external characteristics, internal characteristics, and flow loss characteristics of the micropump were quantitatively analyzed. The results show that temperature mainly affects the micropump performance by changing the viscosity and density of the working fluid. At low temperatures, the fluid viscosity increases significantly, leading to increased flow resistance, intensified internal friction, reduced head and efficiency, and increased shaft power. As the temperature increases to 0 °C and above, the viscosity change tends to moderate, and the external characteristic parameters tend to stabilize. The internal characteristic analysis shows that under low-temperature conditions, the high-pressure region in the impeller area expands and the turbulent kinetic energy decreases, but the flow separation is to a certain extent suppressed. The region near the volute tongue and the impeller outer edge are the main areas of entropy production loss, and their entropy production rates increase significantly with decreasing temperature. Moreover, at low temperatures, the high entropy production regions expand from locally isolated distributions to continuous large-scale distributions. The impeller outer edge dominates total entropy production, driven by peak fluid linear velocity and intense shear interaction with the volute wall. The findings elucidate how working fluid temperature governs both the hydrodynamic performance and the irreversible loss characteristics of the micropump. These insights can directly inform the engineering design of thermal management loops intended for orbital applications under severe temperature swings.

AerospaceVol. 13(8)
Affordable and clean energy
Openalex Percentile: Top 16%
Microfluidic and Capillary Electrophoresis Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.