Preliminary Single-Center Evaluation of the Alifax Molecular Mouse Sepsis Panel for Rapid Detection of Bloodstream Pathogens

Background/Objectives: We evaluated the diagnostic performance of the Alifax Molecular Mouse (MM) sepsis panel for rapidly directly detecting pathogens and resistance genes in positive blood culture broths. Methods: In this prospective single-center study, 40 positive blood culture specimens were analyzed using four MM cartridges targeting Gram-positive and -negative bacteria and major antimicrobial resistance genes. The results were compared with those obtained using the routine microbiological protocol, including organism identification using the MALDI Biotyper system and antimicrobial susceptibility testing using the VITEK 2 and MicroScan WalkAway systems. Additionally, the MM panel results were compared with those obtained using the FilmArray BCID2. Results: Compared with the routine protocol, the MM panel achieved a positive percent agreement (PPA) of 89.5% (34/38; 95% confidence interval [CI], 75.9–95.8%) for bacterial identification, indicating moderate-to-good diagnostic performance. For antimicrobial resistance gene detection, the PPA was 92.1% (35/38; 95% CI, 79.2–97.3%). Compared with the FilmArray BCID2, the overall agreement of the MM panel was 89.4% (34/38) for bacterial identification and 84.2% (32/38) for antimicrobial resistance gene detection. The MM panel generated clinically actionable results within 1 h (mean turnaround time, 55.5 min; 95% CI, 55.1–55.9 min), substantially reducing the turnaround time compared with the conventional microbiological workflow, which requires 1.5–2 days for subculture and automated antimicrobial susceptibility testing. Conclusions: The MM sepsis panel enabled rapid, direct identification of bloodstream pathogens and key antimicrobial resistance markers from positive blood cultures, substantially reducing turnaround time and exhibiting its potential as an adjunct to routine microbiological workflows.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-07-28
DOI
https://doi.org/10.3390/diagnostics16152369
Primary Topic
Bacterial Identification and Susceptibility Testing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preliminary Single-Center Evaluation of the Alifax Molecular Mouse Sepsis Panel for Rapid Detection of Bloodstream Pathogens

Jay Ho Han, Sung Jin Jo, Jae Kwon Kim, Jung Ok Kim et al.
Diagnostics
Bacterial Identification and Susceptibility Testing
article

Preliminary Single-Center Evaluation of the Alifax Molecular Mouse Sepsis Panel for Rapid Detection of Bloodstream Pathogens

Jay Ho Han, Sung Jin Jo, Jae Kwon Kim, Jung Ok Kim, Jung Suk Lee
article en

Abstract

Background/Objectives: We evaluated the diagnostic performance of the Alifax Molecular Mouse (MM) sepsis panel for rapidly directly detecting pathogens and resistance genes in positive blood culture broths. Methods: In this prospective single-center study, 40 positive blood culture specimens were analyzed using four MM cartridges targeting Gram-positive and -negative bacteria and major antimicrobial resistance genes. The results were compared with those obtained using the routine microbiological protocol, including organism identification using the MALDI Biotyper system and antimicrobial susceptibility testing using the VITEK 2 and MicroScan WalkAway systems. Additionally, the MM panel results were compared with those obtained using the FilmArray BCID2. Results: Compared with the routine protocol, the MM panel achieved a positive percent agreement (PPA) of 89.5% (34/38; 95% confidence interval [CI], 75.9–95.8%) for bacterial identification, indicating moderate-to-good diagnostic performance. For antimicrobial resistance gene detection, the PPA was 92.1% (35/38; 95% CI, 79.2–97.3%). Compared with the FilmArray BCID2, the overall agreement of the MM panel was 89.4% (34/38) for bacterial identification and 84.2% (32/38) for antimicrobial resistance gene detection. The MM panel generated clinically actionable results within 1 h (mean turnaround time, 55.5 min; 95% CI, 55.1–55.9 min), substantially reducing the turnaround time compared with the conventional microbiological workflow, which requires 1.5–2 days for subculture and automated antimicrobial susceptibility testing. Conclusions: The MM sepsis panel enabled rapid, direct identification of bloodstream pathogens and key antimicrobial resistance markers from positive blood cultures, substantially reducing turnaround time and exhibiting its potential as an adjunct to routine microbiological workflows.

DiagnosticsVol. 16(15)
The Catholic University of Korea Uijeongbu St. Mary's Hospital (KR), The Catholic University of Korea Seoul St. Mary's Hospital (KR), Catholic University of Korea (KR)
Openalex Percentile: Top 11%
Bacterial Identification and Susceptibility Testing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.