Software-Assisted Subtraction with Ultrasound-Correlated Interpretation Reduces Interpretive Ambiguity in Parathyroid Scintigraphy: A Preliminary Prospective Reporting Study

Background/Objectives: Parathyroid imaging is used for preoperative localization rather than biochemical diagnosis. Conventional planar and SPECT-based scintigraphy may yield equivocal reports when thyroid activity obscures lesion localization. This study evaluated whether combining software-assisted subtraction imaging with ultrasound-correlated interpretation improves reporting certainty and reduces ambiguity. Methods: This prospective reporting study included 96 consecutive patients referred for parathyroid scintigraphy because of biochemical or clinical suspicion of primary hyperparathyroidism. Each anonymized imaging dataset was evaluated by two independent consensus reader pairs using different interpretation strategies. The control arm (CTRL) used conventional dual-time-point Tc-99m sestamibi planar and SPECT images with Tc-99m pertechnetate thyroid images. The intervention arm (INT) additionally used software-assisted subtraction images and ultrasound-correlated interpretation. Endpoints included suspected parathyroid adenoma (PTA)-positive reporting, certainty, clinically actionable localization, high-confidence localization, and non-actionable reporting. Surgical/pathological reference localization was available in 22 operated patients. Results: INT increased PTA-positive reporting compared with CTRL [82/96 (85.4%) vs. 53/96 (55.2%), p < 0.001]. Median certainty increased from 1 (IQR, 0–2) to 3 (IQR, 1–3) (p < 0.001). Clinically actionable localization increased from 32/96 (33.3%) to 68/96 (70.8%) (p < 0.001), and high-confidence localization increased from 17/96 (17.7%) to 55/96 (57.3%) (p < 0.001). Non-actionable reporting decreased from 64/96 (66.7%) to 28/96 (29.2%). In the operated subgroup, correct localization was higher with INT [20/22 (90.9%) vs. 12/22 (54.5%), p = 0.008]. Conclusions: Software-assisted subtraction imaging, when combined with ultrasound-correlated interpretation, improved the clinical usability of conventional parathyroid scintigraphy by increasing reporting certainty, reducing ambiguity, and improving actionable localization. Reference-based findings were supportive, and ongoing follow-up is expected to provide surgical/pathological confirmation for robust diagnostic accuracy analyses.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-07-28
DOI
https://doi.org/10.3390/diagnostics16152379
Primary Topic
Parathyroid Disorders and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Software-Assisted Subtraction with Ultrasound-Correlated Interpretation Reduces Interpretive Ambiguity in Parathyroid Scintigraphy: A Preliminary Prospective Reporting Study

Ercüment Gurluler, Seçkin Bilgiç, Kadircan Karatoprak, Irem Koroglu et al.
Diagnostics
Parathyroid Disorders and Treatments
article

Software-Assisted Subtraction with Ultrasound-Correlated Interpretation Reduces Interpretive Ambiguity in Parathyroid Scintigraphy: A Preliminary Prospective Reporting Study

Ercüment Gurluler, Seçkin Bilgiç, Kadircan Karatoprak, Irem Koroglu, Elif İşleyen Çolak, E. Alper, Degercan Yesilyurt, Ozen Oz Gul
article en

Abstract

Background/Objectives: Parathyroid imaging is used for preoperative localization rather than biochemical diagnosis. Conventional planar and SPECT-based scintigraphy may yield equivocal reports when thyroid activity obscures lesion localization. This study evaluated whether combining software-assisted subtraction imaging with ultrasound-correlated interpretation improves reporting certainty and reduces ambiguity. Methods: This prospective reporting study included 96 consecutive patients referred for parathyroid scintigraphy because of biochemical or clinical suspicion of primary hyperparathyroidism. Each anonymized imaging dataset was evaluated by two independent consensus reader pairs using different interpretation strategies. The control arm (CTRL) used conventional dual-time-point Tc-99m sestamibi planar and SPECT images with Tc-99m pertechnetate thyroid images. The intervention arm (INT) additionally used software-assisted subtraction images and ultrasound-correlated interpretation. Endpoints included suspected parathyroid adenoma (PTA)-positive reporting, certainty, clinically actionable localization, high-confidence localization, and non-actionable reporting. Surgical/pathological reference localization was available in 22 operated patients. Results: INT increased PTA-positive reporting compared with CTRL [82/96 (85.4%) vs. 53/96 (55.2%), p < 0.001]. Median certainty increased from 1 (IQR, 0–2) to 3 (IQR, 1–3) (p < 0.001). Clinically actionable localization increased from 32/96 (33.3%) to 68/96 (70.8%) (p < 0.001), and high-confidence localization increased from 17/96 (17.7%) to 55/96 (57.3%) (p < 0.001). Non-actionable reporting decreased from 64/96 (66.7%) to 28/96 (29.2%). In the operated subgroup, correct localization was higher with INT [20/22 (90.9%) vs. 12/22 (54.5%), p = 0.008]. Conclusions: Software-assisted subtraction imaging, when combined with ultrasound-correlated interpretation, improved the clinical usability of conventional parathyroid scintigraphy by increasing reporting certainty, reducing ambiguity, and improving actionable localization. Reference-based findings were supportive, and ongoing follow-up is expected to provide surgical/pathological confirmation for robust diagnostic accuracy analyses.

DiagnosticsVol. 16(15)
Bursa Uludağ Üni̇versi̇tesi̇ (TR), Sağlık Bilimleri Üniversitesi (TR), S.B.Ü. Bursa Yüksek İhtisas Eğitim ve Araştırma Hastanesi (TR)
Openalex Percentile: Top 9%
Parathyroid Disorders and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.