Micro‐QuEChERS Extraction for Broad‐Spectrum LC‐QQQ‐MS Quantification of Nitazene Analogs in Plasma: A Validated Method With Casework Application

ABSTRACT Nitazenes are highly potent synthetic opioids of increasing concern in clinical and forensic toxicology, thus underscoring the need for sensitive and selective analytical methods for biological specimens. This study describes the development and validation of an LC–MS/MS method for the quantification of nitazene analogs and related metabolites in plasma using micro‐QuEChERS sample preparation. The validated concentration range was 0.05–20 ng/mL, with coefficients of determination R 2 > 0.99. The limit of detection (LOD) was 0.025 ng/mL, and the lower limit of quantification (LLOQ) was 0.05 ng/mL. Bias ranged from −2.6% to 15.7%, within‐run precision from 3.4% to 12.7%, and between‐run precision from 4.4% to 14.9%, as evaluated at three quality control levels. Matrix effects and recovery were analyte‐dependent but compatible with satisfactory overall validation performance. No interferences or carryover were observed. Method applicability was demonstrated in an authentic intoxication case, in which N ‐pyrrolidino protonitazene was quantified at 1.4 ng/mL, representing, to our knowledge, the first clinical case reported in Brazil. The case was clinically characterized by severe opioid toxicity requiring repeated naloxone administration. The proposed method combined low sample volume, simple sample preparation, and suitable analytical performance for targeted analysis of emerging nitazene compounds. These findings support the use of micro‐QuEChERS and LC–MS/MS as a practical approach for targeted nitazene quantification in clinical and forensic toxicology.

Authors

Institutions

Publication Details

Journal
Drug Testing and Analysis
Published
2026-07-28
DOI
https://doi.org/10.1002/dta.70126
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Micro‐QuEChERS Extraction for Broad‐Spectrum LC‐QQQ‐MS Quantification of Nitazene Analogs in Plasma: A Validated Method With Casework Application

Karla A.O. Souza, Rafael Lanaro, Maurı́cio Yonamine, Alex J. Krotulski et al.
Drug Testing and Analysis
Analytical chemistry methods development
article

Micro‐QuEChERS Extraction for Broad‐Spectrum LC‐QQQ‐MS Quantification of Nitazene Analogs in Plasma: A Validated Method With Casework Application

Karla A.O. Souza, Rafael Lanaro, Maurı́cio Yonamine, Alex J. Krotulski, Barry Kerr Logan, José Luiz Costa, Náthaly Cristine Bueno Faria dos Santos, Sara E. Walton
article en

Abstract

ABSTRACT Nitazenes are highly potent synthetic opioids of increasing concern in clinical and forensic toxicology, thus underscoring the need for sensitive and selective analytical methods for biological specimens. This study describes the development and validation of an LC–MS/MS method for the quantification of nitazene analogs and related metabolites in plasma using micro‐QuEChERS sample preparation. The validated concentration range was 0.05–20 ng/mL, with coefficients of determination R 2 > 0.99. The limit of detection (LOD) was 0.025 ng/mL, and the lower limit of quantification (LLOQ) was 0.05 ng/mL. Bias ranged from −2.6% to 15.7%, within‐run precision from 3.4% to 12.7%, and between‐run precision from 4.4% to 14.9%, as evaluated at three quality control levels. Matrix effects and recovery were analyte‐dependent but compatible with satisfactory overall validation performance. No interferences or carryover were observed. Method applicability was demonstrated in an authentic intoxication case, in which N ‐pyrrolidino protonitazene was quantified at 1.4 ng/mL, representing, to our knowledge, the first clinical case reported in Brazil. The case was clinically characterized by severe opioid toxicity requiring repeated naloxone administration. The proposed method combined low sample volume, simple sample preparation, and suitable analytical performance for targeted analysis of emerging nitazene compounds. These findings support the use of micro‐QuEChERS and LC–MS/MS as a practical approach for targeted nitazene quantification in clinical and forensic toxicology.

Drug Testing and Analysis
Universidade de São Paulo (BR), Universidade Estadual de Campinas (UNICAMP) (BR), Fredric Rieders Family Foundation (US)
Openalex Percentile: Top 12%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.